Sanyo C4232, CL4232 service manual Selecting the Installation Site, Avoid

Page 34

8. INSTALLATION INSTRUCTIONS

2)Selecting the Installation Site

Indoor Unit

AVOID:

ãareas where leakage of flammable gas may be expected.

ãplaces where large amounts of oil mist exist.

ãdirect sunlight.

ãlocations near heat sources which may affect performance of the unit.

ãlocations where external air may enter the room directly. This may cause “sweating” on the air discharge ports, causing them to spray or drip.

ãlocations where the remote control unit will be splashed with water or affected by dampness or humidity.

ãinstalling the remote control unit behind curtains or furniture.

ãlocations where the receiver in the indoor unit is exposed to the inverter lamp light. Faulty operation of the unit occurs.

DO:

ãselect an appropriate position from which every corner of the room can be uniformly cooled.

ãselect a location where the ceiling is strong enough to support the weight of the unit.

ãselect a location where tubing and drain pipe have the shortest run to the outdoor unit.

ãallow room for operation and maintenance as well as unrestricted air flow around the unit.

ãinstall the unit within the maximum elevation difference above or below the outdoor unit and within a total tubing length from the outdoor unit as detailed in Table 1.

ãallow room for mounting the remote control unit about 3 ft. off the floor, in an area that is not in direct sunlight nor in the flow of cool air from the indoor unit.

NOTE

Air delivery will be degraded if the distance from the floor to the ceiling is greater than 10 ft..

Ceiling-Mounted Type

 

Ceiling

 

Wall

Min.10 inch

Min.10 inch

Front view

NOTE

The rear of the indoor unit can be installed flush against the wall.

AirCeiling discharge

 

 

 

Air intake

Min.2ft.

 

 

 

 

 

 

 

Side view

1379_T_I

Recessed Type

3 ft.

3 ft.

 

 

3 ft.

3 ft.

3 ft.

1330_X_S

SM830078

– 34 –

Image 34
Contents XS4232 C4232 Indoor Unit Outdoor UnitTS4232 …In a Room Please Read Before Starting…In Moist or Uneven Locations Table of Contents Introduction Read Me First XS4232, TS4232 / C4232 Operating RangeXS4232, TS4232 / CL4232 Unit Specifications SpecificationsModel No Indoor Unit XS4232 Outdoor Unit C4232 Model No Indoor Unit XS4232 Outdoor Unit Cooling Low ambient control Major Component Specifications Indoor Unit Model No TS4232 Source Auto louver motorMajor Component Specifications Outdoor Unit Controller P.C.B. Assy Model No CL4232 SourceHeat exchange Float switch Other Component Specifications Indoor UnitModel No XS4232 Power Transformer Thermistor Coil sensorModel No TS4232 Power Transformer Model No C4232 Other Component Specifications Outdoor UnitPower Relay Thermostat Coil sensorModel No CL4232 Dimensional Data Indoor Unit XS4232Indoor Unit TS4232 19/32Outdoor Unit C4232, CL4232 Cooling Capacity Indoor Unit XS4232 Outdoor Unit C4232, CL4232208V / 1 phase / 60Hz Indoor Unit TS4232 Outdoor Unit C4232, CL4232 800 CFM 230V Performance ChartsOperating Current Indoor Unit XS4232 Outdoor Unit C4232 208VOperating Current Indoor Unit TS4232 Outdoor Unit C4232Operating Current Indoor Unit XS4232 Outdoor Unit CL4232 Operating Current Indoor Unit TS4232 Outdoor Unit CL4232 Low Pressure Suction Outdoor ambient temp. F C Indoor temp. F C 104 AIR Throw Distance Chart Model XS4232Refrigerant Flow Diagram Indoor Unit 4232 Type Outdoor Unit C4232, CL4232Installation Instructions Tubing LengthSelecting the Installation Site AvoidCase of multiple installations Wind Shield for CL Model Recommended outer dimensions of wind shield field supplyAir Discharge Chamber for Top Discharge GeneralWiring System Diagram Electrical Wiring General Precautions on WiringOutdoor Unit C, CL models Single-phase 60 Hz, 208 / 230 Electrical Data Indoor model TS4232 / Outdoor model C4232, CL4232Electric Wiring Diagram Electrical Wiring DiagramsSchematic Diagram 854-2-5268-593-00-0 TS3632 RY1~RY5 Diagram Compressor Motor Electric Wiring Diagram CL4232 Outdoor UnitFMO1 Room Temperature Control Processes and FunctionsFreeze Prevention Drain Pump ControlOutdoor Fan Speed Control C4232 Type CL4232 TypeService Procedures 1340XS Check remote control unit There is a possibility of short circuitCheck compressor motor protectors High pressure switch 63PH Check Operation selector switch in the indoor unitTransformer in indoor unit Check fuse on the P.C.B. Ass’y in the indoor unit Check. auxiliary relay Y or 2YXS Type only Check set temperature Check Cool / FAN selector switch in the remote control unitOutdoor Unit does not Run Check compressor motor magnetic contactor Check indoor unit P.C.B Check outdoor unit P.C.B CL3632 TypeSome Part does not Operate. A. Indoor fan does not run Indoor Unit does not RunIndoor fan and louver motor do not run Louver motor does not runOutdoor Fan does not Run Outdoor Fan does not Run for CL4232 Compressor does not RunPoor Cooling Excessive CoolingRoom temp. Sensor in the remote control unit is defective Operation of Major Electrical PartsPower Supply Wires Measurement of Insulation Resis- tance for Electrical partsChecking the Protective Devices Compressor motor thermal protector . . . . . . Outdoor unitIndoor fan motor FMI Indoor unit Measure the coil resistance Motor capacitor Both in indoor and outdoor unitMethod Used to Replace Fuse on PCB Ass’y Check for continuity using a multimeter as shown in FigContinuity of fuse on P.C.B. Ass’y Room temp. sensor KTEC-35Central Region

CL4232, C4232 specifications

The Sanyo C4232 and CL4232 are renowned models in the realm of electronics, particularly celebrated within the realm of consumer appliances and consumer electronics. As part of Sanyo’s esteemed lineup, these models are crafted with both functionality and performance in mind, appealing to a wide demographic of users.

One of the standout features of the Sanyo C4232 and CL4232 is their energy efficiency. Both models leverage advanced technology to minimize power consumption, making them environmentally friendly options. This is particularly beneficial in today’s world, where sustainable practices are becoming increasingly vital. Users can enjoy the performance of these devices without the guilt of excessive energy expenditure.

In terms of design, the Sanyo C4232 and CL4232 showcase a sleek and modern aesthetic, incorporating user-friendly interfaces that simplify operation. The control panels are intuitively designed, allowing users to navigate options effortlessly. This focus on user experience is evident in the thoughtfulness of the layout and accessibility of controls, making these models suitable for consumers of all ages.

The Sanyo C4232 and CL4232 are also equipped with a variety of advanced features that enhance their usability. For instance, many models come with multiple settings that cater to different user needs, whether it be cooking, cooling, or heating. This versatility ensures that the units can effectively meet diverse requirements, making them indispensable in any household.

Another key characteristic of these models is their durability. Sanyo products are known for their robust construction and long-lasting performance. By utilizing high-quality materials and rigorous testing processes, Sanyo ensures that both the C4232 and CL4232 can withstand the rigors of daily use, providing consumers with reliable service over time.

Modern technology is integrated throughout the Sanyo C4232 and CL4232 models, including smart functionalities that align with contemporary lifestyles. Many of these appliances can be connected to home networks, allowing for remote control and monitoring via mobile devices. This connectivity not only enhances convenience but also allows users to manage their energy consumption efficiently.

In summary, the Sanyo C4232 and CL4232 offer a blend of efficiency, user-friendly design, durability, and modern technology. These models exemplify Sanyo’s commitment to providing practical and reliable solutions for consumers, making them worthy investments for any household looking to enhance their quality of life through innovative electronics.