Sanyo CL4232, C4232 service manual Case of multiple installations

Page 35

8. INSTALLATION INSTRUCTIONS

Outdoor Unit

AVOID:

ãheat sources, exhaust fans, etc. (Fig. 2)

ãdamp, humid or uneven locations.

DO:

Hot air

Out- door unit

Exhaust fan

Heat source

0591_C_I

ãchoose a place as cool as possible.

ãchoose a place that is well ventilated and

outside air temperature does not exceed maximum 115°F constantly.

ãallow enough room around the unit for air intake/ exhaust and possible mainte- nance. (Fig. 3)

ãprovide a solid base; about 6 inch above ground level to reduce humidity and possible water damage in the unit and decreased service life. (Fig. 4)

ãuse lug bolts or equivalent to bolt down unit, reducing vibration and noise.

Min.

1 inch

Fig. 2

Min. Obstacle above 1 inch

 

Min.

4 in.

7 ft.

Air dis- charge

Min. 2 ft.

0931_C_I

Ground

0932_C_I

Fig. 3

In case of multiple installations

Unit spacing if air discharge chamber is not used.

 

Unit spacing when air discharge chamber is used.

Min. 4 ft.

Min. 5 ft.

Min. 4 ft.

Min. 4 ft.

Min. 8 inch

Min. 4 ft.

 

 

Min. 1 ft.

 

Min. 1 ft. 2 inch

 

Air

 

 

 

 

discharge

 

 

 

 

 

 

 

 

 

 

chamber

 

 

 

Min. 1 ft. 2 inch

 

 

 

Min. 12 ft.

 

 

 

 

 

 

 

 

 

Min. 1 ft.

 

Min. 8 inch

 

 

 

Min. 1 ft.

If you would like to make the separation smaller on the air discharge side, use an air discharge chamber.

You can install any number of units side-by -side.

Only up to 3 units can be installed side-by-side under the above conditions. The next group must be spaced at least 1 ft. away from the first group.

Air in

Air discharge

Concrete block

4 inch × 1 ft. 4 inch beams or equal

Anchor bolts (4 pieces)

0933_C_S

Air in

Min. 6 inch

Fig. 4

0934_C_I

SM830078

– 35 –

Image 35
Contents TS4232 Indoor Unit Outdoor UnitXS4232 C4232 …In Moist or Uneven Locations Please Read Before Starting…In a Room Table of Contents Introduction Read Me First XS4232, TS4232 / CL4232 Operating RangeXS4232, TS4232 / C4232 Model No Indoor Unit XS4232 Outdoor Unit C4232 SpecificationsUnit Specifications Model No Indoor Unit XS4232 Outdoor Unit Cooling Low ambient control Major Component Specifications Indoor Unit Auto louver motor Model No TS4232 SourceMajor Component Specifications Outdoor Unit Heat exchange Model No CL4232 SourceController P.C.B. Assy Thermistor Coil sensor Other Component Specifications Indoor UnitModel No XS4232 Power Transformer Float switchModel No TS4232 Power Transformer Thermostat Coil sensor Other Component Specifications Outdoor UnitPower Relay Model No C4232Model No CL4232 Indoor Unit XS4232 Dimensional Data19/32 Indoor Unit TS4232Outdoor Unit C4232, CL4232 Indoor Unit XS4232 Outdoor Unit C4232, CL4232 Cooling Capacity208V / 1 phase / 60Hz Indoor Unit TS4232 Outdoor Unit C4232, CL4232 800 CFM 208V Performance ChartsOperating Current Indoor Unit XS4232 Outdoor Unit C4232 230VOutdoor Unit C4232 Operating Current Indoor Unit TS4232Operating Current Indoor Unit XS4232 Outdoor Unit CL4232 Operating Current Indoor Unit TS4232 Outdoor Unit CL4232 Low Pressure Suction Outdoor ambient temp. F C Indoor temp. F C 104 Model XS4232 AIR Throw Distance ChartIndoor Unit 4232 Type Outdoor Unit C4232, CL4232 Refrigerant Flow DiagramTubing Length Installation InstructionsAvoid Selecting the Installation SiteCase of multiple installations General Recommended outer dimensions of wind shield field supplyAir Discharge Chamber for Top Discharge Wind Shield for CL ModelOutdoor Unit C, CL models Single-phase 60 Hz, 208 / 230 Electrical Wiring General Precautions on WiringWiring System Diagram Indoor model TS4232 / Outdoor model C4232, CL4232 Electrical DataElectrical Wiring Diagrams Electric Wiring DiagramSchematic Diagram 854-2-5268-593-00-0 TS3632 RY1~RY5 Diagram Compressor Motor CL4232 Outdoor Unit Electric Wiring DiagramFMO1 Processes and Functions Room Temperature ControlDrain Pump Control Freeze PreventionCL4232 Type Outdoor Fan Speed Control C4232 TypeService Procedures 1340XS There is a possibility of short circuit Check remote control unitTransformer in indoor unit Check Operation selector switch in the indoor unitCheck compressor motor protectors High pressure switch 63PH XS Type only Check. auxiliary relay Y or 2YCheck fuse on the P.C.B. Ass’y in the indoor unit Outdoor Unit does not Run Check Cool / FAN selector switch in the remote control unitCheck set temperature Check indoor unit P.C.B Check outdoor unit P.C.B CL3632 Type Check compressor motor magnetic contactorLouver motor does not run Indoor Unit does not RunIndoor fan and louver motor do not run Some Part does not Operate. A. Indoor fan does not runOutdoor Fan does not Run Compressor does not Run Outdoor Fan does not Run for CL4232Excessive Cooling Poor CoolingOperation of Major Electrical Parts Room temp. Sensor in the remote control unit is defectiveMeasurement of Insulation Resis- tance for Electrical parts Power Supply WiresCompressor motor thermal protector . . . . . . Outdoor unit Checking the Protective DevicesMotor capacitor Both in indoor and outdoor unit Indoor fan motor FMI Indoor unit Measure the coil resistanceRoom temp. sensor KTEC-35 Check for continuity using a multimeter as shown in FigContinuity of fuse on P.C.B. Ass’y Method Used to Replace Fuse on PCB Ass’yCentral Region

CL4232, C4232 specifications

The Sanyo C4232 and CL4232 are renowned models in the realm of electronics, particularly celebrated within the realm of consumer appliances and consumer electronics. As part of Sanyo’s esteemed lineup, these models are crafted with both functionality and performance in mind, appealing to a wide demographic of users.

One of the standout features of the Sanyo C4232 and CL4232 is their energy efficiency. Both models leverage advanced technology to minimize power consumption, making them environmentally friendly options. This is particularly beneficial in today’s world, where sustainable practices are becoming increasingly vital. Users can enjoy the performance of these devices without the guilt of excessive energy expenditure.

In terms of design, the Sanyo C4232 and CL4232 showcase a sleek and modern aesthetic, incorporating user-friendly interfaces that simplify operation. The control panels are intuitively designed, allowing users to navigate options effortlessly. This focus on user experience is evident in the thoughtfulness of the layout and accessibility of controls, making these models suitable for consumers of all ages.

The Sanyo C4232 and CL4232 are also equipped with a variety of advanced features that enhance their usability. For instance, many models come with multiple settings that cater to different user needs, whether it be cooking, cooling, or heating. This versatility ensures that the units can effectively meet diverse requirements, making them indispensable in any household.

Another key characteristic of these models is their durability. Sanyo products are known for their robust construction and long-lasting performance. By utilizing high-quality materials and rigorous testing processes, Sanyo ensures that both the C4232 and CL4232 can withstand the rigors of daily use, providing consumers with reliable service over time.

Modern technology is integrated throughout the Sanyo C4232 and CL4232 models, including smart functionalities that align with contemporary lifestyles. Many of these appliances can be connected to home networks, allowing for remote control and monitoring via mobile devices. This connectivity not only enhances convenience but also allows users to manage their energy consumption efficiently.

In summary, the Sanyo C4232 and CL4232 offer a blend of efficiency, user-friendly design, durability, and modern technology. These models exemplify Sanyo’s commitment to providing practical and reliable solutions for consumers, making them worthy investments for any household looking to enhance their quality of life through innovative electronics.