Sanyo CL4232 Unit Specifications, Model No Indoor Unit XS4232 Outdoor Unit C4232

Page 6

2. SPECIFICATIONS

(1) Unit Specifications

 

MODEL No.

 

Indoor Unit

 

 

XS4232

 

 

 

 

 

Outdoor Unit

 

 

C4232

 

 

 

POWER SOURCE

 

 

 

 

230 - 208 V / 1 Phase / 60 Hz

 

 

PERFORMANCE

 

 

 

 

 

Cooling

 

 

 

Capacity

 

 

BTU / h

42,000

 

 

40,500

 

 

 

 

 

 

 

kW

12.32

 

 

11.88

 

 

Air circulation (Hi)

 

 

cu.ft. / min.

980

 

 

880

 

 

Moisture removal (High)

 

 

Pints / h

14.6

 

 

14.8

 

 

ELECTRICAL RATINGS

 

 

 

 

 

 

 

 

 

 

Voltage rating

 

 

 

VAC

230

 

 

208

 

 

Available voltage range

 

 

 

VAC

 

187 - 253

 

 

 

Running amperes*

 

 

 

A

20.8

 

 

21.1

 

 

Max. running amperes**

 

 

 

A

24.1

 

 

25.3

 

 

Power input

 

 

 

W

4,230

 

 

4,120

 

 

Power factor

 

 

 

%

88

 

 

94

 

 

S.E.E.R

 

 

BTU / Wh

10.2

 

 

10.3

 

 

Max. starting amperes

 

 

 

A

134

 

 

134

 

 

Maximum fuse size

 

 

 

A

 

50

 

 

 

FEATURES

 

 

 

 

 

 

 

 

 

 

Controls

 

 

 

 

 

Microprocessor

 

 

Timer

 

 

 

 

ON / OFF 24-hours & Program

 

 

Fan speed Indoor / Outdoor

 

 

 

 

3 and Automatic control / 2 (Auto)

 

 

Air deflection

Horizontal / Vertical

 

– / Automatic

 

 

 

Air filter

 

 

 

 

Washable, easy access, long life (2,500 hr)

 

Remote controller (Accessory)

 

 

 

 

 

RCS - 5PS4U

 

 

Refrigerant control

 

 

 

 

 

Capillary tube

 

 

Refrigerant tubing connections

 

 

 

 

 

Flare type

 

 

 

Drain pump / Drain pipe trade size

 

 

 

Max. head 9-27/32 in. above drain connection / 3/4 in. (26.7 mm)

 

Compressor

 

 

 

 

 

Scroll

 

 

 

Operation sound

 

Indoor - Hi / Me / Lo

dB - A

 

43 / 40 / 36

 

 

 

 

 

Outdoor - Hi

 

dB - A

 

56

 

 

 

REFRIGERANT TUBING

 

 

 

 

 

 

 

 

 

 

Limit of tubing length

 

 

ft.

(m)

 

165 (50)

 

 

 

Limit of tubing length at shipment

 

ft.

(m)

 

50 (15)

 

 

 

Limit of elevation difference

 

 

ft.

(m)

Outdoor unit is higher than indoor unit: 165 (50)

 

between the two units

 

 

 

 

Outdoor unit is lower than indoor unit: 100 (30)

 

Refrigerant tube

 

Narrow tube

 

in. (mm)

 

3 / 8 (9.52)

 

 

 

outer diameter

 

Wide tube

 

in. (mm)

 

3 / 4 (19.05)

 

 

 

Refrigerant amount at shipment

 

lbs. (kg)

 

R22 : 9.7 (4.4)

 

 

DIMENSIONS & WEIGHT

 

 

 

 

Indoor unit

 

Outdoor unit

 

Unit dimensions

 

Height

 

in. (mm)

11-1/32

(280)

 

48-5/8

(1,235)

 

 

 

Width

 

in. (mm)

41-11/32

(1,050)

 

37

(940)

 

 

 

Depth

 

in. (mm)

29-29/32

(760)

 

13-3/8

(340)

 

Net weight

 

 

 

lbs. (kg)

60

(27)

 

205

(93)

 

Indoor grille dimensions

 

Height

 

in. (mm)

3-1/16

(78)

 

 

 

 

 

Width

 

in. (mm)

45-9/32

(1,150)

 

 

 

 

 

Depth

 

in. (mm)

33-27/32

(860)

 

 

 

Net weight

 

 

 

lbs. (kg)

15

(7)

 

 

 

Indoor Unit

 

Height

 

in. (mm)

12-7/16

(316)

 

52-7/32

(1,326)

 

Package dimensions

 

Width

 

in. (mm)

43-27/32

(1,114)

 

40

(1,016)

 

 

 

Depth

 

in. (mm)

32-25/32

(833)

 

16-3/8

(416)

 

Shipping weight

 

 

 

lbs. (kg)

71

(32)

 

229

(104)

 

Shipping volume

 

cu. ft. (m3)

10.3

(0.293)

 

19.8

(0.56)

 

Indoor grille

 

Height

 

in. (mm)

4-3/32

(104)

 

 

 

Package dimensions

 

Width

 

in. (mm)

49-1/2

(1,257)

 

 

 

 

 

Depth

 

in. (mm)

39-11/32

(999)

 

 

 

Shipping weight

 

 

 

lbs. (kg)

29

(10)

 

 

 

Shipping volume

 

cu. ft. (m3)

4.6

(0.131)

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE

Cooling :

Rating conditions (*) : Indoor air temperature 80 °F DB / 67 °F WB, Outdoor air temperature 95 °F DB / 75 °F WB

Full load conditions (**) : Indoor air temperature 80 °F DB / 67 °F WB, Outdoor air temperature 115 °F DB

SM830078

– 6 –

Image 6
Contents Indoor Unit Outdoor Unit XS4232 C4232TS4232 Please Read Before Starting …In a Room…In Moist or Uneven Locations Table of Contents Introduction Read Me First Operating Range XS4232, TS4232 / C4232XS4232, TS4232 / CL4232 Specifications Unit SpecificationsModel No Indoor Unit XS4232 Outdoor Unit C4232 Model No Indoor Unit XS4232 Outdoor Unit Cooling Low ambient control Major Component Specifications Indoor Unit Model No TS4232 Source Auto louver motorMajor Component Specifications Outdoor Unit Model No CL4232 Source Controller P.C.B. AssyHeat exchange Float switch Other Component Specifications Indoor UnitModel No XS4232 Power Transformer Thermistor Coil sensorModel No TS4232 Power Transformer Model No C4232 Other Component Specifications Outdoor UnitPower Relay Thermostat Coil sensorModel No CL4232 Dimensional Data Indoor Unit XS4232Indoor Unit TS4232 19/32Outdoor Unit C4232, CL4232 Cooling Capacity Indoor Unit XS4232 Outdoor Unit C4232, CL4232208V / 1 phase / 60Hz Indoor Unit TS4232 Outdoor Unit C4232, CL4232 800 CFM 230V Performance ChartsOperating Current Indoor Unit XS4232 Outdoor Unit C4232 208VOperating Current Indoor Unit TS4232 Outdoor Unit C4232Operating Current Indoor Unit XS4232 Outdoor Unit CL4232 Operating Current Indoor Unit TS4232 Outdoor Unit CL4232 Low Pressure Suction Outdoor ambient temp. F C Indoor temp. F C 104 AIR Throw Distance Chart Model XS4232Refrigerant Flow Diagram Indoor Unit 4232 Type Outdoor Unit C4232, CL4232Installation Instructions Tubing LengthSelecting the Installation Site AvoidCase of multiple installations Wind Shield for CL Model Recommended outer dimensions of wind shield field supplyAir Discharge Chamber for Top Discharge GeneralElectrical Wiring General Precautions on Wiring Wiring System DiagramOutdoor Unit C, CL models Single-phase 60 Hz, 208 / 230 Electrical Data Indoor model TS4232 / Outdoor model C4232, CL4232Electric Wiring Diagram Electrical Wiring DiagramsSchematic Diagram 854-2-5268-593-00-0 TS3632 RY1~RY5 Diagram Compressor Motor Electric Wiring Diagram CL4232 Outdoor UnitFMO1 Room Temperature Control Processes and FunctionsFreeze Prevention Drain Pump ControlOutdoor Fan Speed Control C4232 Type CL4232 TypeService Procedures 1340XS Check remote control unit There is a possibility of short circuitCheck Operation selector switch in the indoor unit Check compressor motor protectors High pressure switch 63PHTransformer in indoor unit Check. auxiliary relay Y or 2Y Check fuse on the P.C.B. Ass’y in the indoor unitXS Type only Check Cool / FAN selector switch in the remote control unit Check set temperatureOutdoor Unit does not Run Check compressor motor magnetic contactor Check indoor unit P.C.B Check outdoor unit P.C.B CL3632 TypeSome Part does not Operate. A. Indoor fan does not run Indoor Unit does not RunIndoor fan and louver motor do not run Louver motor does not runOutdoor Fan does not Run Outdoor Fan does not Run for CL4232 Compressor does not RunPoor Cooling Excessive CoolingRoom temp. Sensor in the remote control unit is defective Operation of Major Electrical PartsPower Supply Wires Measurement of Insulation Resis- tance for Electrical partsChecking the Protective Devices Compressor motor thermal protector . . . . . . Outdoor unitIndoor fan motor FMI Indoor unit Measure the coil resistance Motor capacitor Both in indoor and outdoor unitMethod Used to Replace Fuse on PCB Ass’y Check for continuity using a multimeter as shown in FigContinuity of fuse on P.C.B. Ass’y Room temp. sensor KTEC-35Central Region

CL4232, C4232 specifications

The Sanyo C4232 and CL4232 are renowned models in the realm of electronics, particularly celebrated within the realm of consumer appliances and consumer electronics. As part of Sanyo’s esteemed lineup, these models are crafted with both functionality and performance in mind, appealing to a wide demographic of users.

One of the standout features of the Sanyo C4232 and CL4232 is their energy efficiency. Both models leverage advanced technology to minimize power consumption, making them environmentally friendly options. This is particularly beneficial in today’s world, where sustainable practices are becoming increasingly vital. Users can enjoy the performance of these devices without the guilt of excessive energy expenditure.

In terms of design, the Sanyo C4232 and CL4232 showcase a sleek and modern aesthetic, incorporating user-friendly interfaces that simplify operation. The control panels are intuitively designed, allowing users to navigate options effortlessly. This focus on user experience is evident in the thoughtfulness of the layout and accessibility of controls, making these models suitable for consumers of all ages.

The Sanyo C4232 and CL4232 are also equipped with a variety of advanced features that enhance their usability. For instance, many models come with multiple settings that cater to different user needs, whether it be cooking, cooling, or heating. This versatility ensures that the units can effectively meet diverse requirements, making them indispensable in any household.

Another key characteristic of these models is their durability. Sanyo products are known for their robust construction and long-lasting performance. By utilizing high-quality materials and rigorous testing processes, Sanyo ensures that both the C4232 and CL4232 can withstand the rigors of daily use, providing consumers with reliable service over time.

Modern technology is integrated throughout the Sanyo C4232 and CL4232 models, including smart functionalities that align with contemporary lifestyles. Many of these appliances can be connected to home networks, allowing for remote control and monitoring via mobile devices. This connectivity not only enhances convenience but also allows users to manage their energy consumption efficiently.

In summary, the Sanyo C4232 and CL4232 offer a blend of efficiency, user-friendly design, durability, and modern technology. These models exemplify Sanyo’s commitment to providing practical and reliable solutions for consumers, making them worthy investments for any household looking to enhance their quality of life through innovative electronics.