Sanyo PNR-XS2432, XS1852 Finding the Address Switches Remote Control Unit

Page 17

5. Address Switches

If you are installing one indoor unit or one group of indoor units in the same room, it is necessary for you to assign each unit its own address so that each can be operated by its own remote control unit. You assign the addresses by matching the switch position of each indoor unit with the switch position of its remote control unit. The switch of the remote control unit is shown in Fig. 5-1.

5-1. Finding the Address Switches

Remote Control Unit

Remove the lid by sliding it off. You can see the switches inside the battery compartment. (Fig. 5-1)

Indoor Unit

A B

Address

Address switch is in “A” position at time of shipment.

(1)

Turn off the Power Switch.

1008_M_I

 

(2)

Remove the Grille.

 

(3)

Remove the cover of the Electrical Component

Fig. 5-1

 

Box.

 

 

5-2.

Switch Positions for 2 Units or 2 Groups of Units

 

Table 5-1 shows the positions you can use for up to 2

 

units or 2 groups of indoor units installed in the same room. Two remote control units are necessary to allow the respective units or group to be controlled indepen- dently.

Table 5-1

 

 

 

 

 

 

 

 

 

 

 

Remote Control

Indoor Unit

 

 

 

 

 

 

Unit No.

 

Address switch

Address switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

A

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

B

ON

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The indoor unit address switch is set at 1-OFF & 2-OFF

 

 

 

 

 

position at shipment.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

An indoor unit cannot be controlled if its remote control

 

 

 

 

 

 

 

 

 

 

unit is too far away (more than 26 ft.). If the remote

 

 

 

 

 

control unit does not work correctly, bring it closer to

 

 

 

 

 

 

 

 

 

 

the unit being operated and try again. There should be

 

 

 

 

 

P.C.B

no obstacles between the remote control unit and the

 

 

 

 

 

indoor unit. For this reason, if the remote control unit is

 

 

 

 

 

to be used from a fixed position, check the operation

 

 

 

 

 

before mounting.

 

 

 

 

 

 

 

 

 

ON

 

 

1

2

WIRED

WIRELESS

 

R.C.U. Switch

Address Switch

 

(DSW1)

 

1321_M_I

Fig. 5-2

17S4359128

Image 17
Contents Installation Instructions Please Read Before Starting General Models C1852 Tubing Data CL1852 Tubing LengthIndoor Unit Selecting the Installation SiteBaffle Plates for the Outdoor Unit CL⋅⋅ models only Outdoor UnitProvide a solid base level concrete pad, concrete Suspending the Indoor Unit How to Install the Indoor UnitPreparation for Suspending Unit inch mmPlacing the Unit Inside the Ceiling Do not install an air Installing the Drain PipingDo not install the pipe with an upward Backwards and leak when the unit isChecking the Drainage Start turning when checkingBe careful since the fan will DrainageLatch Screw Air intake grille Ceiling panel When Removing the Ceiling Panel for Servicing Installing the Ceiling PanelDuct for Fresh Air Setup for the indoor unitInstalling the Duct Connection BOX Installing the AIR-INTAKE ChamberInstalling the Indoor Unit Take adequate precautions Caution when installing ontoNon-removable mounting Mounting on a WallRemovable mounting Installing the Wired Remote Control Unit Wired Remote Control Unit OptionFinding the Address Switches Remote Control Unit Address SwitchesSwitch Positions for 2 Units or 2 Groups of Units Remote Control Indoor Unit Unit No Address switchGeneral Precautions on Wiring Electrical WiringWiring Instructions for the Outdoor Unit ModelsIndoor Indoor Unit Outdoor Unit ProblemScrewdriver. Fig For stranded wiringFlaring Procedure with a Flare Tool How to Process TubingPrecaution before Connecting Tubes Tightly Use of the Flaring MethodConnecting Tubing between Indoor and Outdoor Units Precautions during BrazingRefrigerant tubing Taping the flare nutsTaping the Tubes Finishing the Installation10 min. or more 15 min. or more Air PurgingHex wrench before Be sure to completely insertPerforming Test Run Be careful since the fan will Performing Test Run with Optional Wired Remote Control UnitTest Run Action Basic Function of the Service ValvesValve 2-Way Valve 3-Way Pump Down
Related manuals
Manual 45 pages 15.8 Kb

PNR-XS2432, XS1852 specifications

The Sanyo XS1852 and PNR-XS2432 are dual offerings that exemplify cutting-edge technology in the realm of compact air conditioning systems. Sanyo, a trusted brand in HVAC solutions, has built these units to cater to both efficiency and comfort, making them ideal for residential and commercial applications.

The Sanyo XS1852 is a wall-mounted split air conditioning system known for its sleek design and powerful performance. It features advanced inverter technology, allowing for variable speed operation. This means the compressor adjusts its speed based on the cooling demand, resulting in significant energy savings and enhanced comfort. The XS1852 operates quietly, producing minimal noise, making it suitable for bedrooms and quiet spaces.

One of the standout features of the XS1852 is its intelligent air distribution. The unit is equipped with multiple airflow settings and swing functions that ensure the air is evenly distributed throughout the room. This feature helps maintain a consistent temperature, avoiding hot or cold spots. The XS1852 also boasts a user-friendly remote control and an intuitive LED display, making it easy to adjust settings even from a distance.

Meanwhile, the PNR-XS2432 is designed for larger spaces, with robust cooling capacities. This ceiling cassette model offers a discreet installation option, fitting seamlessly into various environments. It features a four-way airflow system that enables effective air distribution from all sides, ensuring maximum comfort even in larger rooms. The PNR-XS2432 is also designed with a high energy efficiency rating, providing both cost savings and reduced environmental impact.

Both units incorporate advanced filtration technology, including a multi-layer filtration system that captures dust, allergens, and odors. This feature not only enhances air quality but also contributes to a healthier indoor environment.

Another important characteristic of these models is their compatibility with smart home systems. Users can easily connect these units to their smart devices, allowing remote access and control via mobile applications. This added convenience makes it possible to schedule cooling cycles and monitor energy usage, promoting smarter energy consumption.

In summary, the Sanyo XS1852 and PNR-XS2432 represent a blend of innovative technology, energy efficiency, and user-centric design. They are ideal solutions for anyone seeking reliable and effective air conditioning options that enhance comfort while minimizing environmental impact.