1. General

This booklet briefly outlines where and how to install the air conditioning system. Please read over the entire set of instructions for the indoor and outdoor units and make sure all accessory parts listed are with the system before beginning.

1-1. Tools Required for Installation (not supplied)

1.Standard screwdriver

2.Phillips head screwdriver

3.Knife or wire stripper

4.Tape measure

5.Level

6.Sabre saw or key hole saw

7.Hacksaw

8.Core bits

9.Hammer

10.Drill

11.Tube cutter

12.Tube flaring tool

13.Torque wrench

14.Adjustable wrench

15.Reamer (for deburring)

16.Service valve wrench

17.Wire cutter

1-2. Accessories Supplied with Unit Table 1-1

Part Name

Figure

Q’ty

Remarks

Full-scale

 

 

For determining

installation

 

1

suspension bolt

diagram

 

 

pitch

Flare

 

1

For wide tubes

insulator

 

 

 

 

Installation

 

1

For adjusting the

gauge

 

unit position

 

 

Insulating

 

1

For wide tube

tape

(White for insulating)

flare nuts

 

 

 

 

Hose band

 

2

For securing drain

 

hose

 

 

 

Packing

 

1

For drain joint

Drain

 

1

For drain joint

insulator

 

 

 

 

Drain hose

 

1

 

Drain hose

 

1

For drain outlet

adapter

 

 

 

 

Owner’s

 

1

 

manual

 

 

 

 

 

Hexagonal

 

 

To open and shut

 

1

the Narrow Tube

Wrench*

 

 

 

Service Valve

 

 

 

*Packed in the outdoor unit

 

 

Part Name

Figure

Q’ty

Wireless

 

1

remote control unit

 

 

 

AAA alkaline

 

2

battery

 

 

 

Tapping screw

Special

1

screw

 

4 16 mm

 

Tapping screw

TOTA 4

1

 

16

1-3. Optional Copper Tubing Kit

Copper tubing for connecting the outdoor unit to the indoor unit is available in kits which contain the narrow and wide tubing, fittings and insulation. Consult your nearest sales outlet or A/C workshop.

1-4. Type of Copper Tube and Insulation Material

If you wish to purchase these materials separately from a local source, you will need:

1.Deoxidized annealed copper tube for refrigerant tubing.

Cut each tube 12 in. to 16 in. longer than the appropriate lengths to dampen vibration between units.

2.Foamed polyethylene insulation for 5/8" (15.88 mm) O.D. copper tubes as required to precise length of tubing. Wall thickness of the insulation should be not less than 0.3 inch (8 mm).

Check local electrical codes CAUTION and regulations before

obtaining wire. Also, check any specified instructions or limitations.

1-5. Additional Materials Required for Installation

1.Insulated staples or clamps for connecting wire (See your local codes.)

2.Putty

3.Refrigeration tubing lubricant

4.Clamps or saddles to secure refrigerant tubing

5.Scale for weighing

1-6. Operating Range

 

Temperature

Indoor Air Intake

Outdoor Air Intake

 

 

 

 

Cooling

Maximum

95°F DB, 71°F WB

115°F DB

Minimum

67°F DB, 57°F WB

67°F DB (0°F DB)*

 

 

 

 

 

 

 

 

*CL&&&& Models

3S4359128

Image 3
Contents Installation Instructions Please Read Before Starting General Models C1852 Tubing Data CL1852 Tubing LengthIndoor Unit Selecting the Installation SiteOutdoor Unit Provide a solid base level concrete pad, concreteBaffle Plates for the Outdoor Unit CL⋅⋅ models only Unit inch mm How to Install the Indoor UnitSuspending the Indoor Unit Preparation for SuspendingPlacing the Unit Inside the Ceiling Backwards and leak when the unit is Installing the Drain PipingDo not install an air Do not install the pipe with an upwardDrainage Start turning when checkingChecking the Drainage Be careful since the fan willLatch Screw Air intake grille Ceiling panel When Removing the Ceiling Panel for Servicing Installing the Ceiling PanelDuct for Fresh Air Setup for the indoor unitTake adequate precautions Caution when installing onto Installing the AIR-INTAKE ChamberInstalling the Duct Connection BOX Installing the Indoor UnitMounting on a Wall Removable mountingNon-removable mounting Installing the Wired Remote Control Unit Wired Remote Control Unit OptionRemote Control Indoor Unit Unit No Address switch Address SwitchesFinding the Address Switches Remote Control Unit Switch Positions for 2 Units or 2 Groups of UnitsModels Electrical WiringGeneral Precautions on Wiring Wiring Instructions for the Outdoor UnitIndoor Indoor Unit Outdoor Unit ProblemScrewdriver. Fig For stranded wiringUse of the Flaring Method How to Process TubingFlaring Procedure with a Flare Tool Precaution before Connecting Tubes TightlyTaping the flare nuts Precautions during BrazingConnecting Tubing between Indoor and Outdoor Units Refrigerant tubingTaping the Tubes Finishing the Installation10 min. or more 15 min. or more Air PurgingHex wrench before Be sure to completely insertPerforming Test Run with Optional Wired Remote Control Unit Test RunPerforming Test Run Be careful since the fan will Pump Down Basic Function of the Service ValvesAction Valve 2-Way Valve 3-Way
Related manuals
Manual 45 pages 15.8 Kb

PNR-XS2432, XS1852 specifications

The Sanyo XS1852 and PNR-XS2432 are dual offerings that exemplify cutting-edge technology in the realm of compact air conditioning systems. Sanyo, a trusted brand in HVAC solutions, has built these units to cater to both efficiency and comfort, making them ideal for residential and commercial applications.

The Sanyo XS1852 is a wall-mounted split air conditioning system known for its sleek design and powerful performance. It features advanced inverter technology, allowing for variable speed operation. This means the compressor adjusts its speed based on the cooling demand, resulting in significant energy savings and enhanced comfort. The XS1852 operates quietly, producing minimal noise, making it suitable for bedrooms and quiet spaces.

One of the standout features of the XS1852 is its intelligent air distribution. The unit is equipped with multiple airflow settings and swing functions that ensure the air is evenly distributed throughout the room. This feature helps maintain a consistent temperature, avoiding hot or cold spots. The XS1852 also boasts a user-friendly remote control and an intuitive LED display, making it easy to adjust settings even from a distance.

Meanwhile, the PNR-XS2432 is designed for larger spaces, with robust cooling capacities. This ceiling cassette model offers a discreet installation option, fitting seamlessly into various environments. It features a four-way airflow system that enables effective air distribution from all sides, ensuring maximum comfort even in larger rooms. The PNR-XS2432 is also designed with a high energy efficiency rating, providing both cost savings and reduced environmental impact.

Both units incorporate advanced filtration technology, including a multi-layer filtration system that captures dust, allergens, and odors. This feature not only enhances air quality but also contributes to a healthier indoor environment.

Another important characteristic of these models is their compatibility with smart home systems. Users can easily connect these units to their smart devices, allowing remote access and control via mobile applications. This added convenience makes it possible to schedule cooling cycles and monitor energy usage, promoting smarter energy consumption.

In summary, the Sanyo XS1852 and PNR-XS2432 represent a blend of innovative technology, energy efficiency, and user-centric design. They are ideal solutions for anyone seeking reliable and effective air conditioning options that enhance comfort while minimizing environmental impact.