Sanyo PNR-XS2432, XS1852 installation instructions Selecting the Installation Site, Indoor Unit

Page 5

2. Selecting the Installation Site

Indoor Unit

AVOID:

areas where leakage of flammable gas may be expected.

places where large amount of oil mist exist.

direct sunlight.

locations near heat sources which may affect performance of the unit.

locations where external air may enter the room directly. This may cause “sweating” on the air discharge ports, causing them to spray or drip.

locations where the remote control unit will be splashed with water or affected by dampness or humidity.

installing the remote control unit behind curtains or furniture.

locations where the receiver in the indoor unit is exposed to the inverter lamp light. Faulty operation of the unit occurs.

DO:

select an appropriate position from which every corner of the room can be uniformly cooled.

select a location where the ceiling is strong enough to support the weight of the unit.

select a location where tubing and drain pipe have the shortest run to the outdoor unit.

allow room for operation and maintenance as well as unrestricted air flow around the unit. (Fig. 2-1)

install the unit within the maximum elevation difference above or below the outdoor unit and within a total tubing length from the outdoor unit as detailed in Table 1-2.

allow room for mounting the remote control unit about 3 ft. off the floor, in an area that is not in direct sunlight nor in the flow of cool air from the indoor unit.

NOTE

Air delivery will be degraded if the distance from the floor to the ceiling is greater than 10 ft..

3 ft.

3 ft.

 

 

3 ft.

3 ft.

3 ft.

1330_X_S

Fig. 2-1

5S4359128

Image 5
Contents Installation Instructions Please Read Before Starting General Models C1852 Tubing Data CL1852 Tubing LengthIndoor Unit Selecting the Installation SiteBaffle Plates for the Outdoor Unit CL⋅⋅ models only Outdoor UnitProvide a solid base level concrete pad, concrete Suspending the Indoor Unit How to Install the Indoor UnitPreparation for Suspending Unit inch mmPlacing the Unit Inside the Ceiling Do not install an air Installing the Drain PipingDo not install the pipe with an upward Backwards and leak when the unit isChecking the Drainage Start turning when checkingBe careful since the fan will DrainageLatch Screw Air intake grille Ceiling panel When Removing the Ceiling Panel for Servicing Installing the Ceiling PanelDuct for Fresh Air Setup for the indoor unitInstalling the Duct Connection BOX Installing the AIR-INTAKE ChamberInstalling the Indoor Unit Take adequate precautions Caution when installing ontoNon-removable mounting Mounting on a WallRemovable mounting Installing the Wired Remote Control Unit Wired Remote Control Unit OptionFinding the Address Switches Remote Control Unit Address SwitchesSwitch Positions for 2 Units or 2 Groups of Units Remote Control Indoor Unit Unit No Address switchGeneral Precautions on Wiring Electrical WiringWiring Instructions for the Outdoor Unit ModelsIndoor Indoor Unit Outdoor Unit ProblemScrewdriver. Fig For stranded wiringFlaring Procedure with a Flare Tool How to Process TubingPrecaution before Connecting Tubes Tightly Use of the Flaring MethodConnecting Tubing between Indoor and Outdoor Units Precautions during BrazingRefrigerant tubing Taping the flare nutsTaping the Tubes Finishing the Installation10 min. or more 15 min. or more Air PurgingHex wrench before Be sure to completely insertPerforming Test Run Be careful since the fan will Performing Test Run with Optional Wired Remote Control UnitTest Run Action Basic Function of the Service ValvesValve 2-Way Valve 3-Way Pump Down