Sanyo XS1852 Installing the Ceiling Panel, When Removing the Ceiling Panel for Servicing

Page 12

3-7. Installing the Ceiling Panel

(1)Lift the ceiling panel and position it to align the panel hook with the panel catch of the indoor unit.

(5)Install the air filter and air-intake grille by perform- ing the steps in section 3-6 in reverse.

NOTE

The ceiling panel must be mounted in the correct direction. Note that the 2 catches of the panel differ in size.

Confirm that the catches are correctly matched be- tween the ceiling panel and the indoor unit body.

(2)Next, check to see that the ceiling panel is prop- erly aligned with the seamline of the ceiling. If it is not, remove the ceiling panel and slightly readjust the indoor unit body to the proper suspension point.

(3)When the ceiling panel has been properly aligned, use the supplied 4 mounting screws (M5) with washers to permanently fasten the ceiling panel.

(4)Install the wiring connector from the ceiling panel to the connector in the electrical component box of the indoor unit. After installing the connector, use the clamp on the body of the indoor unit to secure the wiring.

NOTE

Rehook the safety string before closing the air-intake grille.

3-8. When Removing the Ceiling Panel for Servicing

When removing the ceiling panel for servicing, remove the air-intake grille and air filter, disconnect the wiring connector inside the electrical component box, and then remove the 4 mounting screws.

Panel catch (pull down)

Ceiling panel

Electrical component box

Clamp

Ceiling panel wiring connector

Connector on unit

(inside electrical component box)

Electrical component box Connector of ceiling panel

Unit body

Panel catch (pull down)

Ceiling panel

Screws M5 with washer

Mark

Air filter

 

Air-intake grille

Fig. 3-15

0967_X_I

12S4359128

Image 12
Contents Installation Instructions Please Read Before Starting General Tubing Length Models C1852 Tubing Data CL1852Selecting the Installation Site Indoor UnitOutdoor Unit Provide a solid base level concrete pad, concreteBaffle Plates for the Outdoor Unit CL⋅⋅ models only How to Install the Indoor Unit Suspending the Indoor UnitPreparation for Suspending Unit inch mmPlacing the Unit Inside the Ceiling Installing the Drain Piping Do not install an air Do not install the pipe with an upward Backwards and leak when the unit isStart turning when checking Checking the DrainageBe careful since the fan will DrainageLatch Screw Air intake grille Ceiling panel Installing the Ceiling Panel When Removing the Ceiling Panel for ServicingSetup for the indoor unit Duct for Fresh AirInstalling the AIR-INTAKE Chamber Installing the Duct Connection BOXInstalling the Indoor Unit Take adequate precautions Caution when installing ontoMounting on a Wall Removable mountingNon-removable mounting Wired Remote Control Unit Option Installing the Wired Remote Control UnitAddress Switches Finding the Address Switches Remote Control UnitSwitch Positions for 2 Units or 2 Groups of Units Remote Control Indoor Unit Unit No Address switchElectrical Wiring General Precautions on WiringWiring Instructions for the Outdoor Unit ModelsProblem Indoor Indoor Unit Outdoor UnitFor stranded wiring Screwdriver. FigHow to Process Tubing Flaring Procedure with a Flare ToolPrecaution before Connecting Tubes Tightly Use of the Flaring MethodPrecautions during Brazing Connecting Tubing between Indoor and Outdoor UnitsRefrigerant tubing Taping the flare nutsFinishing the Installation Taping the TubesAir Purging 10 min. or more 15 min. or moreBe sure to completely insert Hex wrench beforePerforming Test Run with Optional Wired Remote Control Unit Test RunPerforming Test Run Be careful since the fan will Basic Function of the Service Valves ActionValve 2-Way Valve 3-Way Pump Down