Sanyo C0971, C1271, CL0971, CL1271 Address Switch, Address Setting of the Remote Control Unit

Page 107

8. Address Switch

8-1. Address Setting of the Remote Control Unit

The address can be set in order to prevent interference between remote controllers when two Sanyo indoor units are installed near each other. The address is normally set to “A.” To set a different address, it is necessary to change the address on the second remote controller.

NOTE

Once changed, you cannot restore the original address setting of the air conditioner.

(1) Switch on the power source.

(2) Break the address-setting tab marked “A” on the second remote controller to change the address (Fig. 62). When the tab is removed, the address is automatically set to B (Fig. 63).

(3) Press and hold the remote controller ION button and 1 HR TIMER button. At the same time, press the ACL(reset) button. Use a thin object such as the tip of a pen to press the ACL button. When this has been done, “oP-1” (test run) appears, blinking, in the remote controller clock display area.

(4) Each time the 1 HR TIMER button is pressed, the display changes as shown below. Press this button 2 times to change the display to “oP-7” (address setting). (Fig. 64)

Test run mode

 

Selfdiagnostic mode

 

Address setting mode

ION

 

button

(5)

“oP-7” has now been selected for address setting.

(6)

Press the ON/OFF operation button on the remote

Tab

Fig. 62

ACL button

Fig. 63

ON/OFF operation button

1HR.

controller. (Fig. 64) Check that the “beep”signal-

received sound is heard from the second indoor unit

(approximately 5 times). The sound you hear is the

signal that the remote controller address has been

changed.

(7) Finally press the remote controller ACL (reset) but-

ton to cancel the blinking “oP-7” display.

(Fig. 64)

Changing of the second remote controller address is now completed.

A

TIMER button

ACL (Reset) button

Fig. 64

26

Image 107
Contents KS0971 + C0971 + CL0971 KS1271 + C1271 + CL1271 DC Inverter Split System AIR ConditionerPlease Read Before Starting Table of Contents Checking Electrical Components Models KS0971 + CL0971 KS1271 + CL1271 Operating RangeModels KS0971 + C0971 KS1271 + C1271 C0971 SpecificationsUnit Specifications KS0971C1271 KS1271CL0971 CL1271 Indoor Unit Major Component SpecificationsCB-KS1271 Microprocessor 250V 3A Outdoor Unit C0971 Outdoor UnitOutdoor Unit C1271 Outdoor Unit CL0971 Outdoor Unit CL1271 Other Component Specifications Indoor Unit KS0971 Dimensional DataCL0971 CL1271 Outdoor Unit C0971 C1271After a tube has been insulated To break or crack Refrigerant Flow DiagramRefrigerant Flow Diagram Insulation of Refrigerant TubingPerformance Data Temperature ChartsIndoor Unit KS0971  Outdoor Unit CL0971 Indoor Unit KS1271  Outdoor Unit C1271 Indoor Unit KS1271  Outdoor Unit CL1271 C0971 / CL0971 Power Supply 115V Single Phase 60Hz Cooling CapacityCooling Capacity C1271 / CL1271 Cooling Capacity Low Ambient 11,900 BTU/h Room air temp F 26.7C Fan speed High Horizontal distance ft Air Throw Distance ChartsCooling Vertical distance ft Air Axis Vertical C0971 Cooling Electrical CharacteristicsElectrical Data C1271 Cooling CL12718FA2-5257-71600-0 Electric Wiring DiagramsIndoor Unit KS0971 KS1271 WHT RED Outdoor Unit C0971 C1271Outdoor Unit CL0971 CL1271 Address Setting of the Remote Control Unit MaintenanceHow to Connect How to DisconnectPAM- control FunctionsOperation Functions Emergency operationLamp colors Timer backupCT Peak current cut-off control Compressor discharge temperature controlProtective Functions Freeze preventionMethod of Self-Diagnostics TroubleshootingPrecautions before Performing Inspection or Repair Self-diagnostics Lamps Replace the circuit board or the fuse Using the TEST/T-RUN terminalsChecking the Indoor and Outdoor Units Replace the controllerCondition E01 Serial Communication Error Identification ProcedureOff Blinking Illuminated Before the OperationTerminal board Outdoor Unit Condition E12 Outdoor Fan Motor Trouble Diagnosis of Fan MotorElectromagnetic interference Noise Malfunction and Electromagnetic InterferenceNoise malfunction Measurement of Insulation Resistance for Electrical Parts Power Supply CordChecking Electrical Components Measurement of Insulation ResistanceChecking Continuity of Fuse on PCB Assy Characteristics Refrigerant R410A Special Precautions When Servicing UnitCharacteristics of New Refrigerant R410A What is New Refrigerant R410A?Checklist before Servicing Tools Specifically for R410A Tubing Installation ProceduresCase of Compressor Malfunction Procedure for Replacing CompressorExample Never charge a large amountUnit. This may cause Damage to the compressorRecharging Case Refrigerant is LeakingWelding leaking points Use of Existing Units When Tubes are ExtendedCharging Additional Refrigerant Retro-Fitting Existing SystemsKS0971 + C0971 + CL0971 KS1271 + C1271 + CL1271 Features Product Information ContentsAlert Symbols Electrical Requirements Installation LocationSafety Instructions Names of Parts Quiet lamp Green and FAN green modeThis lamp lights during operation in the Quiet mode Unit Display and Operation ButtonRemote Control Unit Display Transmitter Remote Control UnitHR. Timer button Advance buttonAir conditioner makes the room cooler Setting to provide a quieter operating soundSet times every day. For details, see Setting the Timer Air conditioner reduces the humidity in the roomACL button ALL Clear Using the Remote Control UnitHow to Install Batteries Using the Remote Control Unit Set the FAN Speed selector button to the setting you want Operation with the Remote Control UnitPress the Mode selector button and select the desired mode Press the TEMP. setting buttons to change the temperaturePress the ON/OFF operation button Operation with the Remote Control UnitNight Setback Mode is used for saving energy Cooling and DRY ModeQuiet Mode Clicking sound is heard from the air conditioner Power failure during operationSpecial Remarks Operation Indication Setting the TimerExample To set to 1030 pm 1030 pm 710 am 1100 am Present time Setting the TimerHow to set the on time Example To start operation at 710 am To cancel a timer program Press the Cancel buttonOperation together with the Daily ON/OFF Repeat Timer Using the 1-Hour OFF TimerSetting procedure Cancellation procedureSweep function Adjusting the Airflow DirectionSetting the airflow manually HorizontalControl Unit Care and CleaningWhen the air conditioner is not running Operation without the RemotePress in the bottom right Care and CleaningCleaning Intake grilleNegative ion generator metal electrodes inside plastic case How to clean the air clean filterWashing the grille with water Air clean filter FilterTrouble Possible Cause Remedy TroubleshootingOperating Range Appendix B Installation Instructions Contents Installation InstructionsPlease Read Before Starting Optional Copper Tubing Kit Tools Required for Installation not suppliedAccessories Supplied with Unit Table GeneralAdditional Materials Required for Installation Installation Site SelectionBaffle Plate for the Outdoor Unit CLxx models only For Air Discharge Recommended dimensions of the baffle platesAir Intake Baffle Air Discharge Baffle For Air IntakePrecautions for installation Installation procedure Air Intake BaffleMake a Hole How to Install the Indoor UnitRemove the Rear Panel from the Unit If Block, Brick, Concrete or Similar Type Wall Install the Rear Panel on the WallIf Wooden Wall Be sure to wear work gloves Remove the Grille to Install the Indoor UnitHow to remove the grille How to replace the grilleShape the Indoor Side Tubing Wiring Instructions General precautions on wiringDisconnect switch may be required by national or local codes Recommended Wire Length and DiameterWiring Instructions for Inter-unit Connections For Outdoor Unit For solid core wiring or F-cable Loose wiring may causeFore, be sure all wiring is How to connect wiring to the terminal For Indoor UnitRight-side tubing MountingDrain cap Switching drain hose and drain capLeft-side tubing Unit or operate it until all Do not supply power toTubing and wiring to the out To unmount indoor unitWiring Instructions for the Outdoor Unit How to Install the Outdoor UnitFirst refer to . Installation Site Selection Use of the Flaring Method Flaring Procedure with a Flare ToolRefrigerant Tubing To prevent heat loss and wet floors due to dripping of con Connecting Tubing between Indoor and Outdoor UnitsFinishing the Installation Insulation of Refrigerant TubingAir Purging Ant gas to leak. In order to Be sure to completely insertHex wrench before This may cause the refrigerHow to Test Run the Air Conditioner Pump Down Basic Functions of the Service ValvesMounting on a Wall Remote Control Unit Installation PositionAddress Setting of the Remote Control Unit Address Switch

CL0971, C1271, C0971, CL1271 specifications

The Sanyo CL1271, C0971, C1271, and CL0971 are a series of advanced audio and video technologies that showcase Sanyo's commitment to innovation and quality in consumer electronics. These models exemplify solid performance and versatility, catering to a wide range of user needs.

The Sanyo CL1271 is recognized for its compact design and robust functionality. It features high-definition video output, which elevates the viewing experience with crisp images and vibrant colors. Its energy-efficient design is an asset for users who are conscious of power consumption while still seeking premium performance. The device also incorporates advanced audio technologies, ensuring that sound quality matches the high-definition visuals. The integration of built-in speakers eliminates the need for additional audio equipment, making the CL1271 a convenient choice for casual viewing.

The Sanyo C0971 stands out for its user-friendly interface and connectivity features. Equipped with multiple ports, it supports various multimedia inputs, including HDMI, USB, and VGA. This adaptability allows users to connect an array of devices, making it an excellent choice for presentations or media playback. The C0971 also employs sophisticated image processing technology, enhancing the clarity and detail of both video and images. With a focus on ease of use, its intuitive menu navigation allows even novice users to access the full range of features without difficulty.

The Sanyo C1271 builds on the foundation established by its predecessors, adding additional enhancements in terms of screen resolution and color accuracy. With a full HD display, it offers exceptional picture quality that is ideal for both entertainment and educational purposes. This model is particularly suited for professional environments, thanks to its superior performance in bright settings. The C1271's durability and reliability are other key points, making it a long-term investment for users who value quality.

Finally, the Sanyo CL0971 combines portability with powerful features, making it an ideal option for individuals on the go. Its lightweight design ensures easy transport, while the battery life enables prolonged usage without the need for frequent recharges. This model's advanced connectivity options further enhance its versatility, allowing seamless integration with smartphones and tablets.

Overall, the Sanyo CL1271, C0971, C1271, and CL0971 represent a comprehensive solution for anyone seeking high-quality audio-visual equipment. With distinct features and technologies, these models cater to a diverse range of needs, ensuring that users experience the best of what Sanyo has to offer.