Moxa Technologies RS-422, RS-485 Hardware Installation, First Thing to Do Interface Settings

Models: RS-422 RS-485

1 79
Download 79 pages 6.46 Kb
Page 13
Image 13

2

Hardware Installation

The installation of the Industio CI-134 Series consists of hardware and software installation. The hardware installation is detailed in this chapter. The next chapter deals with the software installation for various operating systems.

CAP Jumper

Interface Switch

Data Mode Switch

Termination Resistor Jumper for Port 1 Termination Resistor Jumper for Port 2

Termination Resistor Jumper for Port 4 Termination Resistor Jumper for Port 3

JP1

ON

1 2 3 4

ON

1 2 3 4

JP5 JP6

JP4

JP3

Industio CI-134 Series Board

First Thing to Do: Interface Settings

1.Before installing the board into the slot, you should set all the jumpers and switches to what you want. The default (factor y) settings ar e set to RS-485, Auto Data Dir ection Contr ol mode, indicated as *.

CAP Jumper JP1:

Open * Not forcing the CAP address to 0xA700.

Shor t Force the CAP address to 0xA700. Set to this if you want to do quick har dwar e installation. Or forget the CAP address when you want to re-configure the board with IO-IRQ.

Industio CI-134 Series User’s Manual 2-1

Page 13
Image 13
Moxa Technologies RS-422, RS-485 user manual Hardware Installation, First Thing to Do Interface Settings