Moxa Technologies RS-485 Connection Cable and Cable Wiring, RS-422 Cable Wiring, CI-134

Models: RS-422 RS-485

1 79
Download 79 pages 6.46 Kb
Page 63
Image 63

5

Connection Cable and Cable Wiring

In serial data communications, the term DTE is for Data Terminal Equipment, like PC COM1/2, serial printers and terminals. The term DCE is for Data Communication Equipment, like modems.

RS-422 Cable Wiring

The RS-422 standard uses a balanced voltage digital interface to allow communications of 10M bps on cable length of 4000 feet. Ten receivers can be connected to any one driver for broadcasting systems.

RS-422 pin outs for Industio CI-134 Series:

CI-134

1

TxD-(A)

 

 

 

 

 

 

2

TxD+(B)

 

 

 

1

TxD-(A)

3

RxD+(B)

RTS-(A) 6

 

 

 

 

 

2

TxD+(B)

 

 

4

RxD-(A)

RTS+(B) 7

 

 

 

3

RxD+(B)

 

 

 

5

GND

CTS+(B) 8

 

 

 

4

RxD-(A)

 

 

 

6

RTS-(A)

CTS-(A) 9

 

 

 

5

GND

 

 

 

 

 

 

 

7RTS+(B)

8CTS+(B)

9CTS-(A)

Industio CI-134 Series User’s Manual 5-1

Page 63
Image 63
Moxa Technologies RS-485 user manual Connection Cable and Cable Wiring, RS-422 Cable Wiring, CI-134