Settings for connecting with the remote cameras and switcher (continued)

<Operating procedure>

1.Connect the additional remote cameras and switcher to be introduced and the unit to the network within the same subnet.

2.Open AUTO IP menu [37], turn the F2 dial to display “KEEP IP ADR” and press the F2 dial.

1.AUTO SET KEEP IP ADR

Both the number of devices (all remote cameras and the switcher) currently being managed by the unit and the number of new devices detected are displayed on the LCD panel.

C:001/004 S:0/1

NO

C:001/004

Number of devices currently managed by the unit

+number of new devices detected Number of new devices detected

C:Remote camera, S: Switcher

3.Turn the F2 dial to select “Yes”, and then press the F2 dial.

Auto IP setting starts.

During auto IP setting, the progress is indicated by the number of “” which are reduced one by one.

1.AUTO SET

   

When all the operations have been completed successfully, the following message appears.

1.AUTO SET COMPLETE

The remote cameras can now be operated from the unit.

The function for linking the switcher with the unit can now be used.

zzWhen there is duplication between the IP addresses of the devices in operation and the IP addresses of the additional remote cameras to be introduced, the following message appears and the link settings are not configured.

1.AUTO SET

IP Duplicate!

Check the IP addresses of the additional remote cameras to be introduced, and then perform the auto IP setting operation again.

zzWhen setting the IP addresses failed, the following message appears.

1.AUTO SET

SET UP ERR!

The cause of the problem is likely to be a network malfunction. Check the connection status of the hub and LAN cables, and then retry the auto IP setting operation.

Connection device detection

zzWhen the number of new devices detected by “RENEW IP ADR” or “KEEP IP ADR” exceeds the number of devices that can be registered (100 remote cameras and 1 switcher), “C/S OVER!” appears on the bottom line of the LCD panel.

Auto IP setting can be executed even in this state, but IP addresses will be set only for the number of devices that can be registered.

C:020/100 S:1/1

C/S OVER! YES

zzThe unit may not be able to detect all of the remote cameras when, for example, multiple remote cameras are started at the same time. In such a case, select “RETRY” and then press the F2 dial to retry the operation.

zzWhen the number displayed for the number of new devices detected is lower than the actual number of devices to be set for reasons such as some of the remote cameras or the switcher not being powered on, resolve the problem and then select “RETRY” and press the F2 dial to execute the operation again.

C:020/020 S:1/1

RETRY

Notes

zzWhen adding another remote camera controller (AW-RP120 [this unit] or AW-RP50), set an IP address that is not a duplicate of any IP address within the same network before making the connection.

zzExecute auto IP setting when devices not applicable for auto IP setting (devices other than the remote cameras and switcher) are in a non-operation state. After executing auto IP setting, connect these devices after checking that there is no duplicate IP address within the same network.

34

Image 34 Contents
Operating Instructions It can be downloaded from the home page of Adobe Systems Pp Come aprire i file dei manuali di istruzioni per l’usoRead this first FCC NoteImportant Safety Instructions EMC Notice for the PURCHASER/USER of the Apparatus Performance levelContents Introduction User authenticationRestrictions on use Supported switcher FeaturesSupported remote cameras Accessories Precautions for useMake mount angles suitable for the installation location Precautions for installationExample of embedding the unit in a desktop ZzMount angle attachment position AppearanceUnit mm inch Control panel Parts and their functionsMenu operation section Camera selection section Pan and tilt sectionFocus, zoom and iris section Color adjustment section Menu and memory selection section Indicator section Memory card section User button sectionZzMemory cards About the external DC power supply Rear panelBasic operations of the unit Off Basic operations for the menusShutter SpeedConnections Examples of IP connectionsConnections Examples of serial connections „„Serial connections for AW‑HE120 remote cameras„„Serial connection for a remote camera AW‑HE50 or AW‑HE60 ZzSwitch settings of AW-IF400 Supported camera„„Serial connections for AW-PH650 and camera ZzUse a straight cable category 5 or above for the LAN cableSetting the IP address of the unit Network settings of the unitSetting the subnet mask Setting the default gatewayPort CAM1 Setting the reception port numberSetting Global Area Displaying the MAC addressConnection destination IP addresses Link settingsOverview of related menus and operations CAM1 NoAsign Setting the IP addresses automatically auto IP settingWhen configuring the settings for the first time SW CTLAuto SET Complete Auto SET SET UP ERRAuto SET Auto SET Renew IP ADRRemote camera D C001/004 S0/1CAM2 Network CAM3 Network CAM4 NoAsign Connection destination IP address of CAM4 Turn the F2 dial to select Yes, and then press the F2 dial192.168.000.200 OVER! YES Auto SET Keep IP ADRRetry CAM1 IP Duplicate Swapping connection destination IP addressesCAM1 192.168.000.003 Press the F2 dial to confirm the IP addressSW IP Address Setting the connection destination port numberCAM1 192.168.000.008Selecting a camera group Selecting a camera groupSelecting a remote camera Troubleshooting „„Input/output connectors Specifications„„General Index Memo Memo For business users in the European Union