Panasonic AW-RP120G Swapping connection destination IP addresses, CAM1 192.168.000.003

Page 35

Settings for connecting with the remote cameras and switcher (continued)

Swapping connection destination IP addresses

When auto IP setting is executed, the remote cameras are linked to the camera numbers of the unit and become able to be controlled from the unit.

If the link settings are not as desired, you can use the following procedure to change the settings as you wish.

1.Open SWAP IP menu [38] and turn the F1 dial to display the camera number for which you want to change the setting.

The IP address set as the connection destination of the corresponding camera number is displayed on the second line of the LCD panel.

1.CAM1

192.168.000.001

2.Turn the F2 dial to select the camera (IP address) you want to set as the connection destination.

When you turn the F2 dial, the IP address indication changes and the tally lamp of the remote camera with the corresponding IP address set turns on and the PAN/TILT lever becomes able to be operated.

Identify the remote camera you want to set while checking the tally lamp lighting state and video output.

zzThe IP addresses displayed as the connection destinations are the connection destination IP addresses of the camera numbers with “Network” set as the connection type in CTRL TYPE menu [36].

3.Press the F2 dial to confirm the IP address.

The connection destination IP addresses are swapped between the two camera numbers.

1.CAM1

192.168.000.003

Example:

(1) Original setting

Connection destination IP address of camera number CAM1: 192.168.000.001

Connection destination IP address of camera number CAM3:

192.168.000.003

(2)Open SWAP IP menu [38] and set the connection destination IP address of camera number CAM1 to 192.168.000.003.

(3)The settings change as shown below and which remote camera operates when each of the camera numbers is selected is swapped.

Connection destination IP address of camera number CAM1: 192.168.000.003

Connection destination IP address of camera number CAM3: 192.168.000.001

Notes

zzWhen SWAP IP menu [38] is open, operation of the camera selection buttons [CAMERA SELECT/GROUP SELECT] and camera control (IRIS, FOCUS, ZOOM and CAMERA OSD) are not possible.

zzThe IP addresses set on the remote cameras are not changed by this operation.

Manually setting the connection destination IP addresses (remote cameras)

Use the following procedure when connecting (via a router) remote cameras whose IP addresses cannot be set by following the steps in “Auto IP setting” or to manually configure the link settings for the unit and remote cameras.

1.Open MANUAL IP menu [39] and turn the F1 dial to display the camera number for which you want to change the setting.

1.CAM1

192.168.000.001

2.Use the F2 dial to set the IP address for the connection destination.

Enter this in four blocks of numerals.

Enter all of the blocks and then press the F2 dial to confirm the IP address.

The IP addresses can also be set for camera numbers with “NoAsign” or “Serial” set as the connection type in CTRL TYPE menu [36].

zzThis is set to the following value by default.

CAM1

: 192.168.000.010

 

CAM100

: 192.168.000.109

zzWhen a connection destination IP address is changed, a check for IP address duplication is conducted.

If the same IP address is used more than once, the “IP Duplicate!” message is displayed for 3 seconds.

The settings are reflected as is even if connection destination IP addresses are duplicated.

1.CAM1

IP Duplicate!

Note

zzThe IP addresses set on the remote cameras are not changed by this operation.

35

Image 35 Contents
Operating Instructions Pp Come aprire i file dei manuali di istruzioni per l’uso It can be downloaded from the home page of Adobe SystemsFCC Note Read this firstImportant Safety Instructions Performance level EMC Notice for the PURCHASER/USER of the ApparatusContents Restrictions on use User authenticationIntroduction Supported remote cameras FeaturesSupported switcher Precautions for use AccessoriesExample of embedding the unit in a desktop Precautions for installationMake mount angles suitable for the installation location Unit mm inch AppearanceZzMount angle attachment position Menu operation section Parts and their functionsControl panel Pan and tilt section Camera selection sectionFocus, zoom and iris section Color adjustment section Menu and memory selection section Indicator section ZzMemory cards User button sectionMemory card section Rear panel About the external DC power supplyBasic operations of the unit Speed Basic operations for the menusShutter OffExamples of IP connections ConnectionsConnections „„Serial connections for AW‑HE120 remote cameras Examples of serial connections„„Serial connection for a remote camera AW‑HE50 or AW‑HE60 Supported camera ZzSwitch settings of AW-IF400ZzUse a straight cable category 5 or above for the LAN cable „„Serial connections for AW-PH650 and cameraSetting the default gateway Network settings of the unitSetting the subnet mask Setting the IP address of the unitDisplaying the MAC address Setting the reception port numberSetting Global Area Port CAM1Overview of related menus and operations Link settingsConnection destination IP addresses SW CTL Setting the IP addresses automatically auto IP settingWhen configuring the settings for the first time CAM1 NoAsignAuto SET Renew IP ADR Auto SET SET UP ERRAuto SET Auto SET CompleteCAM2 Network CAM3 Network CAM4 NoAsign C001/004 S0/1Remote camera D 192.168.000.200 Turn the F2 dial to select Yes, and then press the F2 dialConnection destination IP address of CAM4 Retry Auto SET Keep IP ADROVER! YES Press the F2 dial to confirm the IP address Swapping connection destination IP addressesCAM1 192.168.000.003 CAM1 IP Duplicate192.168.000.008 Setting the connection destination port numberCAM1 SW IP AddressSelecting a camera group Selecting a camera groupSelecting a remote camera Troubleshooting „„General Specifications„„Input/output connectors Index Memo Memo For business users in the European Union