8 - 2 VOLUME ADJUSTMENT/REPLACEMENT
Never touch places other than those specified. Touching unspecified places can cause electric shock and/or short circuit.
After the replacement or adjustment of the VR, be sure to set the variable value of the VR in the test mode’s Volume Setting.
Volume adjustment/replacement should be performed after the HANDLE MECHA has been removed as per 8 - 1.
ADJUSTMENT
1In order to turn the HANDLE SHAFT, insert the STEERING HANDLE into the HANDLE SHAFT.
2Secure the HANDLE at the centering position.
3 Loosen the 2 screws which secure the VOLUME BRACKET to push the gear out of mesh.
4With the HANDLE SHAFT at the centering position, bring the gear into mesh so that the position of the volume’s shaft is as shown in the Fig.
5Fasten the screws securing the VOLUME BRACKET.
6After the work is finished, perform Volume Setting in the Test mode.