REPLACEMENT
Be sure to turn the power off first, before performing work, and avoid touching unspecified places. Failure to do so can cause electric shock and/or short circuit.
1 Turn power off.
2Take out the 2 truss screws and remove the Potentiocover.
3Disconnect the connector of the volume to be replaced.
4Remove the screw which secures the Potentiobase.
5Remove the Potentiobase together with the volume attached.
6Remove the base and the gear to replace the volume.
7After replacing, check to see if the volume value varies in accordance with operation of the pedal.
10 - 3 GREASING
Be sure to turn the power off first, before performing work, and avoid touching unspecified places. Failure to do so can cause electric shock and/or short circuit.
Be sure to use the designated grease. Using undesignated grease can cause parts damage
Do not apply greasing to undesignated places. Doing so can cause malfunctioning or quality deterioration of parts.
Apply greasing to the following portions once every three (3) months. For Spray Grease, use NOK GLUBER L60 or GREASE MATE (Part No.