SSI America user manual Model 9200 Programmable Dual-loop Controller

Page 21

Model 9200 Programmable Dual-loop Controller

to change the minutes press the “min” key. The next screen that pops up in both cases is a numeric keypad. Enter the number of minutes that you wish to permanently change the recipe to and press the “Enter” key. If you DO NOT wish to make any changes press the “Esc” key. Note, if you wish to only change the minutes, you must enter the desired hour(s), if other than 0.

If you have made a change, pressing the “Enter” key takes you back to the “Time Edit” screen. If you wish to make the change, press the “set” key on the right-hand side of the screen. The next screen to pop up verifies the time has been changed to the number of minutes that you have selected. Pressing the “cancel” key takes you back to the full program screen. If you are sure that you want the change to be permanent press the “set” key. This takes you back to the screen that shows you the entire program. Notice that the time has been changed on the program segment that you were editing. If you wish to save this change press the “save” key. You will notice that a numeric keypad pops up and asks you to enter the number of the program that you wish to save. “Enter” You must enter the desired program number you wish to save these changes to.

NOTE: See the APPENDIX section of this manual for a sample program. The “Esc” button takes you back to the “default” menu.

CO Factor Entry

Pressing the “login key” takes you to the “enter password” screen. Entering the correct password (the default password is “2”) displays the “default” menu which includes:

Highlighting the “CO Factor Entry” and pressing “Enter” pops up the “Factor Entry” screen, showing the parameter as CO Factor and Value as is currently in the Series 9200. To make an adjustment press the “Enter” key. A numeric keypad will be displayed. Using the keypad enter the number that you wish the CO Factor to be and press the “Enter” key. This returns you to the original “Factor Entry” screen, which now shows the new CO Factor that you have entered. If you do not wish to make the change simply press the “Esc” key which takes you back to the “Factor Entry” screen with NO change being made to the CO Factor.

The COF factor allows you to make adjustments that will allow the controller to match the results obtained when measuring shim stock. If the controller set point and the process variable are the same, but you are not attaining the desired surface carbon, you can make the adjustment with the COF Factor to increase the amount of surface carbon available to the parts. If you lower the COF factor, it immediately lowers the % Carbon process variable. This will cause the controller to add more enriching gas--- raising the process variable until once again the process variable and the set point match. Conversely, raising the COF Factor will cause the process variable to read higher, shutting down the enriching gas solenoid (possibly turning on the air dilution solenoid) causing the % Carbon process variable to begin to lower (NOT ADDING ENRICHING GAS) until the set point and process variable match.

Pressing the “Esc” button takes you back to the “Menu Screen”

SSi Manual SERIES 9200

21

Programmable Dual-loop

Image 21
Contents Model 9200 Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller 24VDC / 1 AMP Ohms Total IP10 hand protected Model 9200 Terminals Connections Model 9200 Programmable Dual-loop Controller SSi requirement Installation Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Configuration Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Adam VC Base Aipc Model 9200 Programmable Dual-loop Controller Step Opcode Temperature Atmosphere Option Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Calibrate Span input 1 range Span input 2 range Zero input 3 range Zero Output Span Output Enter measured output current mA Supervisor Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Programs Parameter Value Series 9200 Opcodes Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller Applications Information Series 9200 Factory defaults August 17 Rev August 6 Model 9200 Programmable Dual-loop Controller Model 9200 Programmable Dual-loop Controller OPT Code Temp SET PT Rev Description Date