IW4/IW7 WB/WBV | Operations |
3.6Imbalance Display (Optional)
!Imbalance display
The imbalance display will show the difference between the
The brake force difference should not exceed the legal permissable value.
!Testing in the large measuring range
If a vehicle is tested using the large measurement range (measurement range
3.7Special Features on Test Stands with MB Mode
Selection of the operating mode
Test stands with
•"Automatic" : the rollers will start up automatically after the
• "Manual" : the rollers are started one after the other manually by using the remote control. Observe the green lamp which indicates in which operational mode the test stand is.
The green lamp will extinguish if the pit safety system is triggered.
Switching on the unoccupied test stand
The "Automatic" operational mode is started by turning on the main switch while the test stand is unoccupied. Use the selector switch to switch to "Manual" operation.
Switching on the occupied test stand
The "Manual" operational mode is started by turning on the main switch while the test stand is occupied. The test stand can only be switched to "Automatic" operational mode when it is unoccupied.
Acknowledging malfunctions
Test stands with
If the trouble occurs while the test stand is occupied, it immediately switches to "Manual" operation.
D1 | 25 |