AYXP7FR
CHAPTER 1. SPECIFICATION
[1] SPECIFICATION
1. AY-XP7FR – AE-X7FR
|
|
| MODEL | INDOOR UNIT | OUTDOOR UNIT |
ITEMS |
|
|
| ||
Cooling capacity(Min. > Max.) |
| kW | 2.1 (0.9 - 2.5) |
| |
Heating capacity(Min. > Max.) |
| kW | 2.4 (0.9 - 3.4) |
| |
Moisture removal(at cooling) |
| Liters/h |
|
| |
Electrical data |
|
|
|
|
|
Phase |
|
|
| Single |
|
Rated frequency |
|
| Hz | 50 |
|
Rated voltage |
|
| V | 230 |
|
Rated current ✩ | Cool |
| A | 2.5 (1.0 - 4.1) |
|
(Min - Max.) | Heat |
| A | 2.4 (0.9 - 4.5) |
|
Rated input ✩ | Cool |
| W | 530 (200 - 760) |
|
(Min - Max.) | Heat |
| W | 510 (160 - 1100) |
|
Power factor ✩ | Cool |
| % | 92 |
|
| Heat |
| % | 92 |
|
Compressor | Type |
| Hermetically sealed rotary type | ||
| Model |
|
| ||
| Oil charge |
| 370cc (VG74) |
| |
Refrigerant system | Evaporator |
| Louver Fin and Grooved tube type | ||
| Condenser |
| Corrugate Fin and Grooved tube type | ||
| Control |
| Expansion valve |
| |
| Refrigerant (R410A) | 830g |
| ||
| Micro computer controled reversed systems | ||||
Noise level | High |
| dB(A) | 37 | 45 |
(at cooling) | Low |
| dB(A) | – | – |
| Soft |
| dB(A) | 28 | – |
Fan system |
|
|
|
|
|
Drive |
|
|
| Direct drive |
|
Air flow quantity | High |
| m3/min. | 8.0 | 23.2 |
(at cooling) | Low |
| m3/min. | 6.8 | – |
| Soft |
| m3/min. | 5.5 | – |
Fan |
|
|
| Cross flow fan | Propeller fan |
Connections |
|
|
|
|
|
Refrigerant coupling |
|
|
| Flare type |
|
Refrigerant tube size Gas, Liquid | 3/8", 1/4" |
| |||
Drain piping mm |
|
|
| O.D φ18 |
|
Others |
|
|
|
|
|
Safety device |
|
|
| Compressor: Thermal protector | |
|
|
|
| Fan motors: Thermal fuse | |
|
|
|
| Fuse, Micro computer control | |
Air filters |
|
|
| Polypropylene net (Washable) | |
Net dimensions | Width |
| mm | 790 | 730 |
| Height |
| mm | 278 | 540 |
| Depth |
| mm | 198 | 250 |
Net weight |
|
| kg | 10 | 33 |
1 – 1