Sharp AE-X7FR, AY-XP12FR, AY-XP7FR Model Indoor Unit Outdoor Unit Items AY-XP9FR AE-X9FR

Page 3

AYXP7FR

2. AY-XP9FRAE-X9FR

 

 

 

MODEL

INDOOR UNIT

OUTDOOR UNIT

ITEMS

 

 

 

AY-XP9FR

AE-X9FR

Cooling capacity(Min. > Max.)

 

kW

2.64 (0.9 - 3.0)

 

Heating capacity(Min. > Max.)

 

kW

3.1 (0.9 - 4.8)

 

Moisture removal(at cooling)

 

Liters/h

 

 

Electrical data

 

 

 

 

 

Phase

 

 

 

Single

 

Rated frequency

 

 

Hz

50

 

Rated voltage

 

 

V

230

 

Rated current

Cool

 

A

3.7 (1.0 - 4.8)

 

(Min - Max.)

Heat

 

A

3.5 (0.9 - 6.1)

 

Rated input

Cool

 

W

780 (200 - 960)

 

(Min - Max.)

Heat

 

W

730 (160 - 1400)

 

Power factor

Cool

 

%

92

 

 

Heat

 

%

91

 

Compressor

Type

 

Hermetically sealed rotary type

 

Model

 

DA89X1F-23F

 

 

Oil charge

 

370cc (VG74)

 

Refrigerant system

Evaporator

 

Louver Fin and Grooved tube type

 

Condenser

 

Corrugate Fin and Grooved tube type

 

Control

 

Expansion valve

 

 

Refrigerant (R410A)

830g

 

 

De-lce system

Micro computer controled reversed systems

Noise level

High

 

dB(A)

39

45

(at cooling)

Low

 

dB(A)

 

Soft

 

dB(A)

28

Fan system

 

 

 

 

 

Drive

 

 

 

Direct drive

 

Air flow quantity

High

 

m3/min.

8.6

23.3

(at cooling)

Low

 

m3/min.

7.3

 

Soft

 

m3/min.

5.5

Fan

 

 

 

Cross flow fan

Propeller fan

Connections

 

 

 

 

 

Refrigerant coupling

 

 

 

Flare type

 

Refrigerant tube size Gas, Liquid

3/8", 1/4"

 

Drain piping mm

 

 

 

O.D φ18

 

Others

 

 

 

 

 

Safety device

 

 

 

Compressor: Thermal protector

 

 

 

 

Fan motors: Thermal fuse

 

 

 

 

Fuse, Micro computer control

Air filters

 

 

 

Polypropylene net (Washable)

Net dimensions

Width

 

mm

790

730

 

Height

 

mm

278

540

 

Depth

 

mm

198

250

Net weight

 

 

kg

10

33

1 – 2

Image 3
Contents Models AY-XP7FR AE-X7FR AY-XP9FR AE-X9FR AY-XP12FR AY-XP7FR AE-X7FR SpecificationModel Indoor Unit Outdoor Unit Items AY-XP9FR AE-X9FR AY-XP9FR AE-X9FRAY-XP12FR AE-X12FR External Dimension Indoor unitOutdoor unit Indooa unit Outdooa unit Wiring DiagrmSelf-Diagnosis Function and Display Mode Troubleshooting GuideStatus AYXP7FR Main AYXP7FR Inter-unit wiring error mode Symptom Performance Curves AY-XP7FRAY-XP9FR AY-XP12FR