Sharp CV-2P10SC operation manual Operating Conditions, Energy Efficiency Tips

Page 8

PRECAUTIONS

NOTES ON OPERATION

Allow 3 minutes for the compressor to restart cooling.

If you turn the unit off and immediately restart it, allow three minutes for the compressor to restart cooling. There is an electronic device in the unit that keeps the compressor turned off for three minutes for safety.

In the event of a power failure during use, allow 3 minutes before restarting the unit. After power is reinstated, restart the unit. If the power was off for less than three min- utes, be sure to wait at least three minutes before restarting the unit. If you restart the unit within three minutes, a protective device in the unit may cause the compressor to shut off. This protective device will prevent cooling for about 5 minutes. Any previous settings will be cancelled and the unit will return to its initial settings.

Low temperature operation: Is your unit freezing up?

Freezing may occur when the unit is set close to 64°F in low ambient temperature condi- tions, especially at night.

In these conditions, a further temperature drop may cause the unit to freeze. Setting the unit to a higher temperature will prevent it from freezing.

Dehumidification mode increases room temperature.

The unit generates heat during dehumidification mode and the room temperature will rise. Warm air will be blown out from the Exhaust air outlet, but this is normal and does not indicate a problem with the unit.

This unit blows the warm air generated by the unit outside the room via the ex- haust hose while in cool mode.

Accordingly, the same amount of air as that is blown out will enter the room from outside through any openings into the room.

When cooling operation is performed at high humidity conditions, water tank in- side the unit may frequently become full.

When water tank inside the unit is full, the unit stops operating and TIMER, AIR CON and MAXIMUM lamps will blink. In this case, perform drainage to drain out water within the unit.

OPERATING CONDITIONS

• The unit must be operated within the following temperature range.

Mode

Room temperature

Cool

64°F - 95°F

Dehumidification

59°F - 95°F

A built-in safety device may cut off operation if the temperature exceeds these limits.

When cooling operation is performed at high room temperature, the fan may run at a slower speed.

ENERGY EFFICIENCY TIPS

Avoid direct sunlight.

Close blinds, drapes or shades to keep out direct sunlight while in cooling mode.

Keep the filter clean.

Keeping the filter clean greatly aids efficient operation. A dirty filter blocks the flow of air, making your unit work harder and less efficiently.

Turn off unnecessary lights.

Your unit must remove the heat produced by your lights or other heat-producing appli- ances. Turn off any lights or appliances that are not in use.

EN-6

CV-2P10SC_en.indd 6

11.3.22 11:00:12 AM

Image 8
Contents CV-2P10SC Page Contents EnglishFor Customer Assistance the United States Consumer Limited Warranty Consumer Limited Warranty for the U.S. UsersPrecautions Radio or TV InterferenceUsage Cautions Drainage should be performed whenever moving the unitOperating Conditions Energy Efficiency TipsIncluded Suggested Tools for Window Panel InstallationLocation Part Names Front View Rear ViewRemote Control AIR CON Mode onlyION Mode only Remote Control DisplayInstall Window Panel Guard netAttach the guard combined above to Window panelUse the window panel and the adjustment panel Attach the guard combined above to the window panel Inner height of the window 28.3 718mm 45.3 1150mm Installation and Removal of Exhaust Hose Removal of the exhaust hose Remove the window adapter Remove the exhaust hose from the unitPower Plug Check Press the Reset button until you hear another ClickRemove the battery cover Insert two batteries. AAAR03 PRE-OPERATION ChecksHOW to USE the Remote Control Cool Mode Dehumidification ModeUSE for AIR Conditioner To Turn OFFFAN Mode Ventilation ModePress the Mode button to select FAN mode Press the FAN button to set fan speedTo Change AIR Flow Direction UP / Down AIR Flow DirectionPress the Louvers button again to stop the desired position Left / Right AIR Flow DirectionSleep Operation To CancelMAX Cool Operation OFF Timer Timer OperationOn Timer Press the ION button to start operation ION Generator ModeUSE for ION Generator Press the MAX Density button again MAX Density OperationPress the MAX Density button during Ion generator operation OFF Timer Operation Refresh OperationPress the Refresh button during Ion generator operation Press the Refresh button againPress the Power button to start opera Tion Press the Power button during opera TionMain Unit Operation DrainageMaintenance Cleaning the FilterCleaning the Unit and the Remote Control Before NON-USE for a Long PeriodBefore Calling for Service Índice Declaración de ConformidadAcondicionador DE Aire Para Habitacion CV-2P10SC Parte ResponsableSolicitu DE Servicio AL Cliente Estados Unidos Garantía Limitadaal Consumidor Garantía Limitada DEL Consumidor Para Usuarios DE EE.UUPrecauciones Advertencias Para EL USOAdvertencia Para EL Cable Desuministro DE Energia Interferecias de Radio o TVAdvertencia Acerca DE LA CO- Nexión a Tierra Precauciones Para EL USOConsejos Para EL Rendimiento DE Energía Observaciones Sobre EL FuncionamientoCondiciones DE Funcionamiento Ubicación Piezas IncluidasNombre DE LAS Piezas Parte Delantera Parte TraseraControl Remoto Solamente Modo AIR CONSolamente Modo ION ComúnInstalación DEL Panel DE Ventana Instalación en una ventana de guillotina dobleFije el soporte con un tornillo. Recomendado ES-12 ES-13 Instalación Y Desmontaje DE LA Manguera DE Escape Fije el adaptador de la manguera de escape a la unidadES-15 Presione el botón de reinicio Reset Presione el botón Reset hasta que es- cuche otro ClicInspecciones Antes DEL USO Colocacion DE LAS PilasForma DE Usar EL Control Remoto USO Para EL Acondicionador DE Aire Modo EnfriarModo Deshumidificación DesactivaciónModo Ventilador Modo VentilaciónCambio DE LA Dirección DE Flujo DE Aire Dirección DEL Flujo DE Aire Hacia ARRI- BA/ABAJOPresione el botón Louvers Flujo DE LA Corriente DE Aire Hacia LA IZQUIERDA/DERECHAOperacion DE Dormir CancelarOperacion Enfriamiento Maximo Desactivación DEL Temporizador Funcionamiento CON EL TemporizadorActivación DEL Temporizador Presione el botón ION para iniciar el funcio- namiento USO Para Generador DE IONModo ION Generator USO Para ION Generator Operacion Maxima DensidadDirección DE Flujo DE Aire Hacia ARRI- BA/ABAJO Presione nuevamente el botón MAX DensityPresione nuevamente el botón Refresh Operacion RefrescarOperacion Desactivación DEL Temporizador Presione el botón Power para iniciar el Funcionamiento Presione el botón Power durante la operacionFuncionamiento DE LA Unidad Principal DrenajeMantenimiento Limpiando EL FiltroLimpieza DE LA Unidad Y DEL Control Remoto Antes DE UN no USO POR UN Largo PeriodoAntes DE Llamar AL Departamento DE Servicio Técnico Page Sharp Plaza, Mahwah New Jersey 07495-1163 U.S.A

CV-2P10SC specifications

The Sharp CV-2P10SC is a state-of-the-art portable air conditioner designed to deliver efficient cooling performance while prioritizing user comfort and convenience. With a sleek and modern design, this air conditioning unit is not only functional but also enhances the aesthetic appeal of any space it occupies.

One of the standout features of the Sharp CV-2P10SC is its powerful cooling capacity of 10,000 BTU, making it suitable for medium-sized rooms up to 25 square meters. This unit effectively lowers indoor temperatures, providing a refreshing environment during hot summer months. Additionally, it boasts a dehumidification function, which helps remove excess moisture from the air, creating a more comfortable atmosphere.

Equipped with a user-friendly control panel and remote control, the Sharp CV-2P10SC ensures that adjusting temperature settings and other functions is simple and convenient. The intuitive controls allow users to select from multiple fan speeds, temperature settings, and operational modes, including cooling, fan, and dehumidification modes. The programmable timer feature further adds to its versatility, allowing users to set the unit to turn on or off at desired times.

The Sharp CV-2P10SC incorporates advanced technologies for energy efficiency. It is designed with an eco-friendly R32 refrigerant, which has a lower global warming potential compared to traditional refrigerants. This not only supports environmental sustainability but also contributes to reduced energy consumption, ultimately leading to lower electricity bills.

Another significant characteristic of the CV-2P10SC is its portability. The unit comes with integrated wheels, making it easy to relocate from one room to another as needed. This flexibility means users can enjoy cool air in any area of their home, whether it’s the living room, bedroom, or office.

Noise levels are kept to a minimum, thanks to its efficient design and technology, ensuring that the unit operates quietly while delivering powerful cooling performance. This is particularly beneficial for nighttime use or in settings where noise could be disruptive.

Overall, the Sharp CV-2P10SC combines robust cooling capabilities, advanced technology, and user-friendly features to provide an exceptional indoor climate control solution that meets the needs of modern consumers. Whether for daily use or special occasions, it stands out as an excellent choice for anyone seeking reliable and efficient portable cooling.