Siemens 600 brochure Inverter type Input DC PVS500 PVS1000 PVS1500 PVS2000, Output AC, Efficiency

Page 6

© Siemens AG 2012

Technical data of the SINVERT PVS500 inverter (according to IEC)1)

Inverter type

Input DC

PVS500

PVS1000

PVS1500

PVS2000

MPP voltage

V

450 ... 750

450 ... 750

450 ... 750

450 ... 750

Maximum input voltage2)

V

820

820

820

820

Minimum input voltage

V

450

450

450

450

Rated input power

kW

513

1 026

1 539

2 052

Maximum input current

A

1 103

2 206

3 309

4 412

Number of DC inputs

 

3

6

9

12

Maximum current per DC input

A

368

368

368

368

Surge arrester

 

Type 2

Type 2

Type 2

Type 2

Output AC

 

 

 

 

 

 

 

 

 

 

 

Grid connection

 

50/60 Hz 288 V 3 AC

50/60 Hz 288 V 3 AC

50/60 Hz 288 V 3 AC

50/60 Hz 288 V 3 AC

Rated power

kW

500

1 000

1 500

2 000

Maximum output current

A

1 002

2 004

3 006

4 008

Line voltage

V

244.8 ... 316.8

244.8 ... 316.8

244.8 ... 316.8

244.8 ... 316.8

Power factor, inductive

 

0.8

0.8

0.8

0.8

Power factor, capacitive

 

0.8

0.8

0.8

0.8

Efficiency

 

 

 

 

 

 

 

 

 

 

 

European efficiency factor

%

98.1

98.3

98.3

98.3

CEC efficiency factor

%

98.2

98.3

98.3

98.3

Maximum efficiency factor

%

98.4

98.4

98.4

98.4

Further data

 

 

 

 

 

 

 

 

 

 

 

Number of subunits

 

1

2

3

4

Dimensions (H/W/D) per subunit

mm

2 100 x 2 700 x 730

2 100 x 2 700 x 730

2 100 x 2 700 x 730

2 100 x 2 700 x 730

Weight per subunit

kg

2 085

2 085

2 085

2 085

Ambient temperature

 

 

 

 

 

- during operation

°C

0 ... +50

0 ... +50

0 ... +50

0 ... +50

- during storage and transport

°C

-25 ... +70

-25 ... +70

-25 ... +70

-25 ... +70

Relative humidity

%

0 ... 95

0 ... 95

0 ... 95

0 ... 95

Installation altitude

 

 

 

 

 

- maximum permissible

m

2 000

2 000

2 000

2 000

- at rated power

m

0 ... 1 000

0 ... 1 000

0 ... 1 000

0 ... 1 000

Data interface

 

Ethernet

Ethernet

Ethernet

Ethernet

Order number

 

 

 

 

 

 

 

 

 

 

 

Order number (grid frequency 50 Hz)

 

6AG3111-1AH00-

6AG3111-1AH10-

6AG3111-1AH20-

6AG3111-1AH30-

 

 

3AB0

3AB0

3AB0

3AB0

Order number (grid frequency 60 Hz)

 

6AG3111-2AH00-

6AG3111-2AH10-

6AG3111-2AH20-

6AG3111-2AH30-

 

 

3AB0

3AB0

3AB0

3AB0

 

 

 

 

 

 

1)Detailed technical information can be found at: http://support.automation.siemens.com

2)With the 1 000 V option, expandable to 1 000 V (see page 10 and 24).

6SINVERT PVS 600Series central inverters

Image 6
Contents Sinvert Sunny prospects for photovoltaic plants Sunny prospects for photovoltaic plants Contents Cost-effectiveness Features and advantages at a glanceTransformerless, 3-phase Sinvert PVS inverters are ReliabilitySinvert PVS 600Series Efficiency Inverter type Input DC PVS500 PVS1000 PVS1500 PVS2000Output AC Further dataInverter type Input DC PVS585 PVS1170 PVS1755 PVS2340 Inverter type Input DC PVS600 PVS1200 PVS1800 PVS2400 Inverter type Input DC PVS630 PVS1260 PVS1890 PVS2520 Options for Sinvert PVS 600Series inverters Sinvert PVS inverters for solar power plants Sinvert PVS inverters for industrial roof systemsLink between solar power and public AC grid How solar power is fed into the AC gridSinvert PVS CombinerBoxes for bundling partial currents Sinvert PVS CombinerBox 108 120 124 204 See diagram on IEC-compliant inverter stationsIndividual components of the inverter stations Medium-voltage switchgearMaster-slave system with Sinvert PVS Medium-voltage transformerEstablishing communication with PVS and system components Sinvert PVS ComBoxSinvert PVS ControlBox Generating Plants in the Medium-Voltage Grid Bdew Sinvert PVS ComBox Some examples of solar power plants using Sinvert inverters Sinvert puts sunshine into the grid. WorldwideFor fast and easy dimensioning PV plant dimensioning with Sinvert SelectFor an instant, up-to-date overview and rapid intervention PV plant monitoring with WinCCPV plant monitoring with Sinvert WebMonitor Sinvert WebMonitor MobileAppFor devices and accessories Sinvert PVS 600Series invertersSelection and ordering data Options for Sinvert PVS 600Series inverters Options for Sinvert PVS 600Series invertersFuses for Sinvert PVS CombinerBox Service & Support Unique range of complete services for the entire life cycleSpare parts service Service callsService contracts Tailored program of services for Sinvert PVS Spare parts serviceService calls Service contracts 100 200 300Sinvert PVS WarrantyExtension offers Sinvert PVS WarrantyExtensionExtends the period of the standard warranty Sinvert PVS SparesContractSinvert PVS MaintenanceContract offers Sinvert PVS MaintenanceContractRoutine maintenance by Siemens Sinvert PVS FullServiceContract offersGet more information
Related manuals
Manual 11 pages 10.26 Kb