the Management | Module |
Installing |
|
|
|
Installing the Management Module
Removing the Module
5.Turn on the power to the switch by plugging in the power cord. During
At Power On | The switch begins its |
| test. Ports are temporarily disabled until the Switch Management |
| Module configures the ports. |
During Self Test | All Switch and Module LEDs are on for approximately 5 seconds, then |
| just the switch Power and Fault LEDs and the Management Module |
| Self Test and Fault LEDs are on for the remainder of the self test. The |
| switch and module self tests require approximately 15 seconds total. |
After Self Test | The switch Fault LED and the module LEDs (Self Test and Fault) turn off. |
If the module Fault LED stays on or flashes, refer to chapter 7, “Trouble- shooting” in this guide.
You have now completed installation and verification of the module.
To configure IP/IPXcommunication for the Switch Management Module, see chapter 4, “Configuring the Switch From the Console”.
Removing the Module
The module is removed from the switch by reversing the installation steps described earlier in this document. When handling the module, be sure to follow the
| To remove the module, follow these steps: | |
| 1. | Remove power from the switch by unplugging the power cord. |
| 2. | Unscrew the two captured screws holding the module in the switch. |
| 3. | Pull the module out of the slot. |
| 4. | Replace the Management Slot cover plate. |
|
| |
C a u t i o n | Replace the cover plate over the slot using the two screws that hold it in place. | |
| Be careful not to overtighten the screws. When using the switch, the cover | |
| plate must always be installed. This is required for safety and to ensure proper | |
| switch cooling. | |
|
|
|