HP J3178A manual Remote Console Connection Using a Modem and a PC

Page 22

The Switch Console

The Switch Console

Connecting a Console to the Switch

 

Remote Console Connection Using a Modem and a PC

 

Terminal Emulator or Terminal

 

 

N o t e

For remote console management, use a pair of full-duplex, asynchronous

 

(character-mode) modems as shown in figure 3-2.

 

1. Before installing the modems, make sure they are both correctly initial-

 

 

ized. Refer to appendix B, “Modem Configuration” for the correct initial-

 

ization strings.

 

2. At the site where the Switch 208/224 is installed:

 

a.

Connect the modem to the Switch Management Module’s console port

 

 

using a standard “straight-through” RS-232-C modem cable. (For

 

 

modem cable pin-outs, refer to “Modem Cable Pin-Out” on next page.)

 

b.

If necessary, configure the PC or terminal to operate with the current

 

 

serial link configuration of the Switch Management Module.

3. At the site where the console is to be located, connect the PC emulating a terminal, or a terminal to the modem using a standard RS-232-C modem cable. Make sure the terminal and modems are functioning properly, then establish the link between the terminal’s modem and the switch’s modem according to the modem instructions.

 

“straight-through”

RJ-11 telephone

modem cable

cable

 

 

Switch with

 

Management Module

 

External modem

“straight-through”

PC running

a VT-100 terminal program

modem cable

 

or a VT-100 terminal

RJ-11 telephone cable

External modem

(You can also use an internal modem.)

Figure 3-2. Example of Remote Access through a Modem Connection

3-4

Image 22
Contents HP AdvanceStack Switch 208/224 Management Module Page HP AdvanceStack Switch 208/224 Management Module Installation and Reference GuidePublication Number HP FTP Library Service HP Customer Support ServicesHow to get the latest software/agent firmware World Wide WebAdditional HP Support Services HP First Fax Retrieval ServiceLocation Phone Number Contents Monitoring Switch Operation From the Console Spanning Tree Operation Viii Installing the Management Module Installing the Management ModuleInstalling Installing the Management Module Installation StepsAnti-Static Precautions Included PartsRemove the cover plate At Power On Removing the ModuleManagement Module Description OverviewManagement Module Description Management Module DescriptionModule Features Page Switch Console T eConnecting a Console to the Switch Switch ConsoleConnecting a PC or Terminal to the Console RS-232 Port Remote Console Connection Using a Modem and a PC Modem Cable Pin-Out How To Start a Console Session Starting and Ending a Console SessionHow To End a Console Session Main MenuMain Menu Features Screen Structure and Navigation Actions lineHow To Navigate in the Console TaskActionsUsing Password Security Level Actions PermittedCapabilities, also set an Operator password To set Manager and Operator passwordsTo Delete Password Protection To Recover from a Lost Manager PasswordTo Recover from a Lost Operator Password Select Delete Password ProtectionRebooting the Switch Reboot Switch Option in the Main Menu Switch ConsoleExample of a Configuration Change Requiring a Reboot How To Exit from the command prompt Advanced CommandsHow To Use the Advanced Commands Listing of Commands Available under Advanced CommandsPage Configuring the Switch From the Console Configuring the Switch From the ConsoleConfiguring Default values are shown in bracketsConfigurable Features How To Access the Switch ConfigurationSystem Configuration Configuring Configuring the Switch From the ConsolePort Configuration Example of the Port Configuration ScreenIPX Service Configuring the Switch From the Console Internet IP Service To manually configure the switch for IP Using BootpTo configure the switch for Bootp Bootp Operation Where How To Configure the Switch for Snmp Communities Snmp CommunitiesSnmp Communities Add or Edit Screen Trap Receivers Serial Link Configuration 10. The Serial Link Configuration Screen Default ValuesConsole Configuration 11. The Console Configuration Screen Default ValuesSpanning Tree Configuration Press the Space bar to select Yes . This enables STP12. Example of the STP Configuration Screen 13. The Default Network Monitoring Configuration Screen Network Monitoring Port14. Example of Selecting a Monitoring Port Saving Configurations Page Monitoring Switch Operation From the Console Main Menu Data Type PurposeStatus and Counters Menu Monitoring Switch Operation From the ConsoleMonitoring Switch Information Example of Switch InformationPort Status Example of Port StatusPort Counters Example of Port CountersPort Counters Show Details Example of Port Counters Show DetailsAddress Table Example of the Address TablePort Address Table To use the port address tableExample of a Port Address Table for a Specific Port Spanning Tree STP Information Example of Spanning Tree Information10. Example of STP Port Information Operation and read the Ieee 802.1d standards documentEvent Log Severity Date Time System ModuleEvent Log Control Keys Key ActionSwitch Console Using Snmp To Monitor and Manage the Switch Snmp Management Features HP Proprietary MIBs includeSnmp Configuration Process Advanced Management Rmon Ease Support RmonTroubleshooting Checking the Module LEDs TroubleshootingStatus Description Problem/Solution Table Problem SolutionDiagnostic Tests IP Configuration ErrorsTesting the Switch and Management Module Testing the Switch’s Ports and the Links Troubleshooting Resetting the Switch Clearing Passwords on the Switch Console T eHP BBS Page Specifications EnvironmentalSpecifications Supported MibsRegulatory Statements Vcci Class 1 For Japan OnlyPage At the switch Modem ConfigurationEnd Modem Configuration At the user endFile Transfers Downloading an Operating SystemUsing Tftp To Download the OS File File TransfersWriting System Software to FLASH, Back Soon Using the SNMP-Based HP Download Manager Using the Switch-to-Switch DownloadUsing the Zmodem to Download the OS File Jumping to console codeTroubleshooting Tftp Downloads Figure C-3. Example of Message for Download FailureFile to be copied Transferring Switch Configurations Command FunctionConfiguration Zput config remotefile overwrite dos/unix Spanning Tree Operation Spanning Tree Protocol STPSpanning Tree Operation Index Clear button description …Defaultconfig IP/IPX MIB STP Tftp Page 5966-5228