•Workstation that has a terminal emulator application (such as HyperTerminal)
•Serial cable provided with the switch, for connecting the switch to the workstation
•An unused IP address
•Ethernet cable for connecting the switch to the workstation or to a network containing the workstation
•SFPs and FC cables, as required to connect the switch to the fabric
To configure the FC 16B and connect it to a fabric:
1.Replace the factory IP address and related information with the IP information provided by your network administrator by completing the following steps:
a.Remove the shipping plug from the serial port and insert the serial cable provided with the FC 16B.
b.Connect the other end of the serial cable to an
c.Verify that the switch power is on and POST is completed.
d.Disable any serial communication programs running on the workstation.
e.Open a terminal emulator application (such as HyperTerminal on a PC, or TERM in a UNIX environment), and configure as follows:
– In a Windows 95, 98, 2000, or NT environment:
Parameter | Value |
|
|
Bits per second: | 9600 |
Databits: | 8 |
Parity: | None |
Stop bits: | 1 |
Flow control: | None |
18 | Quick Start Guide |