Condition

Acceptable Range

 

 

Vibration (non-operating)

10 G, 0-5 kHz at 1.0 octave/minute

 

 

Dimensions

The following table lists the dimensions of the FC 16B.

Dimension

Value

 

 

Height

1U

 

 

Depth

24 inches (61.0 cm)

 

 

Width

17 inches (43.2 cm)

 

 

Weight (with both power supplies installed)

28.5 lbs (12.9 kg)

 

 

Power Supply

The following table lists the power supply specifications.

Specification

Value

 

 

 

Total power available from

126

Watts, with fans operating

each power supply

 

 

 

 

 

Input voltage

100

- 240 VAC

 

 

Input line frequency

47 - 63 Hz

 

 

Harmonic distortion

Active power factor correction per

 

IEC1000-3-2

 

 

BTU rating

108 Watts x 3.412 BTU/Hr/Watts = 368.5

 

BTU/Hr

 

 

 

Specifications

37

Image 43
Contents Quick start guide Hp surestore fc 1Gb/2Gb switch 16B Warranty Contents Specifications Revision History UpdatesRelated Publications Title Part Number Product Description Safety GuidelinesPackage Contents Installing the Switch as a Stand-Alone Unit FC 16B Rack-Mounted Switch Installing the Switch in a RackInstalling the Switch To install the switch in a rack Installing the Rear Rail-Tray Brackets Compaq/Rittal Rack Installing the Tinnerman Clips HP Rack Installing the Rubber Washers Assembling the Outer Rails HP Rack Installing Switch into an HP Rack Quick Start Guide System Components SetupSFP Media Side of the FC 16B SFP Media SidePower Supply Power Supply SideSFPs Fabric Operating SystemFibre Channel Cable Connections Description Configuring and Connecting the SwitchTo configure the FC 16B and connect it to a fabric Gateway Address 172.17.1.1 Enter the new gateway address Quick Start Guide Setup Backing up the Switch Configuration Settings Saving the System Configuration FilesRestoring the System Configuration Settings Setting Up Speed Negotiation Setting QuickLoop Mode on PortsNext Steps HP Surestore Director FC-64 Switch Configuring Supported DevicesHP Surestore VA Switch Status Indicators DiagnosticsLEDs on the SFP Media Side Diagnostics LEDs on the Power Supply Side Are faulty Maintenance and Diagnostic Tests Test Command Description Service and Support Additional Licenses Error MessagesGetting Support General SpecificationsEnvironmental Power Supply DimensionsQuick Start Guide Product Regulatory Information Germany Noise Declaration Laser Safety Declaration of Conformity Page Page Page A7340-96002