HP A7340-96002 manual Are faulty

Page 37

The following table describes the LEDs on each power supply. These LEDs indicate the status of the related power supply.

Color of LED

Status of Hardware

Recommended Action

 

 

 

No light

Power supply is not providing

 

power.

Verify power supply is on and power cable is connected to a valid power source.

Steady green

Power supply is providing

No action required.

 

power.

 

 

 

 

The following table describes the LED in the center of the power supply side. This LED indicates the status of the switch.

Color of LED

Status of Hardware

Recommended Action

 

 

 

No light

Either the switch is off, or boot

 

is not complete, or boot has

 

failed.

Verify that the switch is on and boot has had time to complete. If there is still no light, contact HP support.

Steady green

Switch is on and boot has

No action required.

 

successfully completed.

 

Steady yellow

Diagnostic command is in

 

progress, or one or more ports

 

are faulty.

If no diagnostic tests are running, check the Port Status LEDs for fault indicators.

Slow-flashing

Diagnostic failure on one or

yellow

more ports.

Errors may be listed in the error log. Refer to the Fabric OS Procedures Guide for more information.

Diagnostics

31

Image 37
Contents Quick start guide Hp surestore fc 1Gb/2Gb switch 16B Warranty Contents Specifications Revision History UpdatesRelated Publications Title Part Number Product Description Safety GuidelinesPackage Contents Installing the Switch as a Stand-Alone Unit FC 16B Rack-Mounted Switch Installing the Switch in a RackInstalling the Switch To install the switch in a rack Installing the Rear Rail-Tray Brackets Compaq/Rittal Rack Installing the Tinnerman Clips HP Rack Installing the Rubber Washers Assembling the Outer Rails HP Rack Installing Switch into an HP Rack Quick Start Guide System Components SetupSFP Media Side of the FC 16B SFP Media SidePower Supply Power Supply SideSFPs Fabric Operating SystemFibre Channel Cable Connections Description Configuring and Connecting the SwitchTo configure the FC 16B and connect it to a fabric Gateway Address 172.17.1.1 Enter the new gateway address Quick Start Guide Setup Backing up the Switch Configuration Settings Saving the System Configuration FilesRestoring the System Configuration Settings Setting Up Speed Negotiation Setting QuickLoop Mode on PortsNext Steps HP Surestore Director FC-64 Switch Configuring Supported DevicesHP Surestore VA Switch Status Indicators DiagnosticsLEDs on the SFP Media Side Diagnostics LEDs on the Power Supply Side Are faulty Maintenance and Diagnostic Tests Test Command Description Service and Support Additional Licenses Error MessagesGetting Support General SpecificationsEnvironmental Power Supply DimensionsQuick Start Guide Product Regulatory Information Germany Noise Declaration Laser Safety Declaration of Conformity Page Page Page A7340-96002