HP 6631B, 6633B, 6632B, 6634B manual Front Panel At a Glance

Page 10

1 – Quick Reference

The Front Panel - At a Glance

j14-character

k Annunciators

display shows output

indicate operating

measurements and

modes and status

programmed values.

conditions.

lRotary control

mOptional front panel

sets voltage, current,

output connectors.

and menu parameters.

 

Use á and â

 

to set the resolution;

 

then adjust the value

 

with the knob.

 

1

2

3

4

5

 

 

6

7

 

8

 

 

nTurns the dc source

o System keys:

p

Function keys:

q Entry keys:

 

on and off.

return to Local

enable/disable

enter values

 

 

 

mode

 

output

increment or

 

set the HP-IB

select metering

 

decrement values

 

 

address

 

functions

ä

and

ã

 

set the RS-232

program voltage

 

select front panel

 

 

interface

 

and current

 

menu parameters.

 

display SCPI

set and clear

á

and

â

 

 

error codes

 

protection

 

select a digit in

 

save and recall

 

functions

 

the numeric entry

 

 

instrument states.

and

 

field.

 

 

 

 

 

 

scroll through the

 

 

 

 

 

 

 

 

front panel menu

 

 

 

 

 

 

 

 

commands.

 

 

 

 

10

Image 10
Contents USER’S Guide Warranty Information CertificationSafety Summary GeneralSafety Symbols Declaration EMCAcoustic Noise Information Printing HistoryTable of Contents Entry Keys Examples of Front Panel Programming Specifications Supplemental CharacteristicsPerforming the Calibration Procedure IntroductionFlexible system features Convenient bench-top featuresQuick Reference Front Panel At a Glance Front Panel Number Entry Use the Function keys and Entry keys to enter a new valueFront Panel Annunciators Immediate Action KeysFront Panel Menus At a Glance Scpi Programming Commands At a Glance ABORt SENSe CALibrateRear Panel At a Glance Use the front panel Address menu toPage Document Orientation General InformationGetting Started Map Accessories Safety ConsiderationsOptions and Accessories OptionsDescription Output Characteristic Inspection InstallationCleaning Damage Packaging MaterialBench Operation LocationRack Mounting Input Connections Connect the Power CordWire Considerations Output ConnectionsVoltage Drops Remote Sense ConnectionsMultiple Load Connections Sense Leads Remote Sense ConnectionsOVP Considerations StabilityPage FLT/INH DIGital I/O Connector Digital I/O ConnectionsFLT/INH Examples RS-232 Interface Controller ConnectionsHP-IB Interface Pin Input/Output DescriptionTurn-On Checkout Using the KeypadIntroduction Checkout Programming Values Checkout ProcedureProcedure Display Explanation Model Voltage OV Prot CurrentProcedure Display Explanation Press 5, EnterCase of Trouble Error MessagesLine Fuse Front panel Operation Front Panel DescriptionLine System Keys Function Keys Display AnnunciatorsRotary Control Entry KeysDisplay Command Function System KeysImmediate Action Keys Function KeysScrolling Keys High Metering KeysDisplay Measurement LOWOC OT OV RI FS Output Control KeysRST Voltprot valueEntry Keys Entry KeysExamples of Front Panel Programming Setting the Output Voltage and CurrentEnable the output Set the output voltageMaking Front Panel Measurements Querying and Clearing Output ProtectionAction Currrang Auto Use the Meter menu for making front panel measurementsCurrdet Acdc To configure the Digio mode of the port, proceed as follows To configure the Ridfi mode of the port, proceed as followsProgramming the Digital Output Port Programming the Output Relay option 760 only Setting the HP-IB Address and RS-232 ParametersConfigure the RS-232 interface as follows Set the HP-IB address as followsSave an operating state in location 1 as follows Select the power-on state of the dc source as followsSaving and Recalling Operating States Recall a saved state as followsPage Specifications Supplemental Characteristics Table A-2. Supplemental CharacteristicsParameter HP 66332A Command ProcessingINH/FLT Characteristics Dynamic MeasurementNet weight Digital I/O CharacteristicsDimensions Shipping weightEquipment Required Test SetupVerification and Calibration Table B-1. Equipment RequiredFigure B-1. Verification & Calibration Test Setup Performing the Verification TestsCurrent Programming and Measurement Accuracy Turn-On CheckoutVoltage Programming and Measurement Accuracy Table B-2. Verification Programming ValuesCurrent Sink Measurement Current Measurement Low RangeCurrrang LOW Current Measurement Low Range Table B- 3. Verification Test Record for HP 6631BCurrent Programming and Measurement High Range Current Sink MeasurementTable B- 5. Verification Test Record for HP 6633B Table B- 6. Verification Test Record for HP 6634BPerforming the Calibration Procedure Front Panel Calibration MenuVoltage Programming and Measurement Calibration Enable Calibration ModeFront Panel Calibration Overvoltage Protection CalibrationNegative Current Programming Calibration Current Programming and High-Range Measurement CalibrationLow-Range Current Measurement Calibration Error Meaning Calibration Error MessagesTable B- 7. HP-IB Calibration Error Messages AC Current Measurement Calibration HP 66332A onlyCalibration Over the HP-IB Changing the Calibration PasswordCalpass Page Error Number List Error MessagesTable C-1. Error Numbers Error Messages Error Messages C Page Line Voltage Conversion Configure the Power TransformerOpen the Unit Install the Correct Line Fuse Close the UnitIndex Index Index Asia Pacific United States of America EuropeJapan Latin AmericaManual Updates
Related manuals
Manual 94 pages 1.46 Kb

6631B, 6633B, 6634B, 6632B specifications

The HP 6632B, 6634B, 6612B, and 6633B are high-performance programmable power supplies that have gained prominence in various testing and measurement applications. These models are part of the HP 6000 series, which is renowned for its reliability and versatility in providing precision power supply solutions.

The HP 6632B offers a dual-output capability, delivering up to 32 volts and 3 amps per channel. It is designed for applications requiring stable and accurate voltage and current supplies. With features like overvoltage protection and short-circuit protection, it ensures the safety of both the device under test and the power supply itself. The programmable voltage and current settings allow operators to automate their testing procedures, increasing efficiency.

The HP 6634B takes performance a step further with multiple outputs, providing up to 32 volts and 5 amps per channel. This model is particularly suited for applications requiring higher current, especially in battery testing and device characterization. The ability to program the device remotely adds an extra layer of usability, making it ideal for integration into automated testing environments.

The HP 6612B model is tailored for users who require a compact and portable power supply solution. It delivers up to 20 volts and 2 amps. Despite its smaller size, it retains essential features like programmable settings and fast transient response, making it suitable for both educational purposes and field testing scenarios.

For users looking for a versatile, multi-channel solution, the HP 6633B presents itself as an excellent choice. This model offers up to 32 volts and 5 amps across multiple outputs. It supports a wide range of programmable features and has an intuitive interface, making it user-friendly for both beginners and experienced engineers. The robust design of the 6633B ensures reliable performance in demanding environments.

All four models utilize advanced linear power supply technology that minimizes ripple and noise, which is critical for sensitive electronic components. Together, these power supplies provide professionals in research, manufacturing, and testing with the precision they need for their experiments and product developments. The combination of programmability, safety features, and high-performance specifications makes the HP 6632B, 6634B, 6612B, and 6633B essential tools for electronic engineers and technicians.