HP 6633B, 6632B, 6631B, 6634B manual Safety Symbols

Page 4

SAFETY SYMBOLS

WARNING

Caution

Direct current

Alternating current

Both direct and alternating current

Three-phase alternating current

Earth (ground) terminal

Protective earth (ground) terminal

Frame or chassis terminal

Terminal is at earth potential. Used for measurement and control circuits designed to be operated with one terminal at earth potential.

Terminal for Neutral conductor on permanently installed equipment

Terminal for Line conductor on permanently installed equipment

On (supply)

Off (supply)

Standby (supply). Units with this symbol are not completely disconnected from ac mains when this switch is off. To completely disconnect the unit from ac mains, either disconnect the power cord or have a qualified electrician install an external switch.

In position of a bi-stable push control

Out position of a bi-stable push control

Caution, risk of electric shock

Caution, hot surface

Caution (refer to accompanying documents)

The WARNING sign denotes a hazard. It calls attention to a procedure, practice, or the like, which, if not correctly performed or adhered to, could result in personal injury. Do not proceed beyond a WARNING sign until the indicated conditions are fully understood and met.

The CAUTION sign denotes a hazard. It calls attention to an operating procedure, or the like, which, if not correctly performed or adhered to, could result in damage to or destruction of part or all of the product. Do not proceed beyond a CAUTION sign until the indicated conditions are fully understood and met.

4

Image 4
Contents USER’S Guide Warranty Information CertificationSafety Summary GeneralSafety Symbols Declaration EMCAcoustic Noise Information Printing HistoryTable of Contents Specifications Supplemental Characteristics Performing the Calibration ProcedureEntry Keys Examples of Front Panel Programming IntroductionFlexible system features Convenient bench-top featuresQuick Reference Front Panel At a Glance Front Panel Number Entry Use the Function keys and Entry keys to enter a new valueFront Panel Annunciators Immediate Action KeysFront Panel Menus At a Glance Scpi Programming Commands At a Glance ABORt SENSe CALibrateRear Panel At a Glance Use the front panel Address menu toPage Document Orientation General InformationGetting Started Map Safety Considerations Options and AccessoriesAccessories OptionsDescription Output Characteristic Installation CleaningInspection Damage Packaging MaterialBench Operation LocationRack Mounting Connect the Power Cord Wire ConsiderationsInput Connections Output ConnectionsVoltage Drops Remote Sense ConnectionsMultiple Load Connections Sense Leads Remote Sense ConnectionsOVP Considerations StabilityPage FLT/INH DIGital I/O Connector Digital I/O ConnectionsFLT/INH Examples Controller Connections HP-IB InterfaceRS-232 Interface Pin Input/Output DescriptionTurn-On Checkout Using the KeypadIntroduction Checkout Procedure Procedure Display ExplanationCheckout Programming Values Model Voltage OV Prot CurrentProcedure Display Explanation Press 5, EnterCase of Trouble Error MessagesLine Fuse Front panel Operation Front Panel DescriptionDisplay Annunciators Rotary ControlLine System Keys Function Keys Entry KeysDisplay Command Function System KeysImmediate Action Keys Function KeysScrolling Keys Metering Keys Display MeasurementHigh LOWOutput Control Keys RSTOC OT OV RI FS Voltprot valueEntry Keys Entry KeysSetting the Output Voltage and Current Enable the outputExamples of Front Panel Programming Set the output voltageMaking Front Panel Measurements Querying and Clearing Output ProtectionAction Currrang Auto Use the Meter menu for making front panel measurementsCurrdet Acdc To configure the Digio mode of the port, proceed as follows To configure the Ridfi mode of the port, proceed as followsProgramming the Digital Output Port Setting the HP-IB Address and RS-232 Parameters Configure the RS-232 interface as followsProgramming the Output Relay option 760 only Set the HP-IB address as followsSelect the power-on state of the dc source as follows Saving and Recalling Operating StatesSave an operating state in location 1 as follows Recall a saved state as followsPage Specifications Supplemental Characteristics Table A-2. Supplemental CharacteristicsCommand Processing INH/FLT CharacteristicsParameter HP 66332A Dynamic MeasurementDigital I/O Characteristics DimensionsNet weight Shipping weightTest Setup Verification and CalibrationEquipment Required Table B-1. Equipment RequiredFigure B-1. Verification & Calibration Test Setup Performing the Verification TestsTurn-On Checkout Voltage Programming and Measurement AccuracyCurrent Programming and Measurement Accuracy Table B-2. Verification Programming ValuesCurrent Sink Measurement Current Measurement Low RangeCurrrang LOW Table B- 3. Verification Test Record for HP 6631B Current Programming and Measurement High RangeCurrent Measurement Low Range Current Sink MeasurementTable B- 5. Verification Test Record for HP 6633B Table B- 6. Verification Test Record for HP 6634BPerforming the Calibration Procedure Front Panel Calibration MenuEnable Calibration Mode Front Panel CalibrationVoltage Programming and Measurement Calibration Overvoltage Protection CalibrationNegative Current Programming Calibration Current Programming and High-Range Measurement CalibrationLow-Range Current Measurement Calibration Calibration Error Messages Table B- 7. HP-IB Calibration Error MessagesError Meaning AC Current Measurement Calibration HP 66332A onlyCalibration Over the HP-IB Changing the Calibration PasswordCalpass Page Error Number List Error MessagesTable C-1. Error Numbers Error Messages Error Messages C Page Line Voltage Conversion Configure the Power TransformerOpen the Unit Install the Correct Line Fuse Close the UnitIndex Index Index United States of America Europe JapanAsia Pacific Latin AmericaManual Updates
Related manuals
Manual 94 pages 1.46 Kb

6631B, 6633B, 6634B, 6632B specifications

The HP 6632B, 6634B, 6612B, and 6633B are high-performance programmable power supplies that have gained prominence in various testing and measurement applications. These models are part of the HP 6000 series, which is renowned for its reliability and versatility in providing precision power supply solutions.

The HP 6632B offers a dual-output capability, delivering up to 32 volts and 3 amps per channel. It is designed for applications requiring stable and accurate voltage and current supplies. With features like overvoltage protection and short-circuit protection, it ensures the safety of both the device under test and the power supply itself. The programmable voltage and current settings allow operators to automate their testing procedures, increasing efficiency.

The HP 6634B takes performance a step further with multiple outputs, providing up to 32 volts and 5 amps per channel. This model is particularly suited for applications requiring higher current, especially in battery testing and device characterization. The ability to program the device remotely adds an extra layer of usability, making it ideal for integration into automated testing environments.

The HP 6612B model is tailored for users who require a compact and portable power supply solution. It delivers up to 20 volts and 2 amps. Despite its smaller size, it retains essential features like programmable settings and fast transient response, making it suitable for both educational purposes and field testing scenarios.

For users looking for a versatile, multi-channel solution, the HP 6633B presents itself as an excellent choice. This model offers up to 32 volts and 5 amps across multiple outputs. It supports a wide range of programmable features and has an intuitive interface, making it user-friendly for both beginners and experienced engineers. The robust design of the 6633B ensures reliable performance in demanding environments.

All four models utilize advanced linear power supply technology that minimizes ripple and noise, which is critical for sensitive electronic components. Together, these power supplies provide professionals in research, manufacturing, and testing with the precision they need for their experiments and product developments. The combination of programmability, safety features, and high-performance specifications makes the HP 6632B, 6634B, 6612B, and 6633B essential tools for electronic engineers and technicians.