HP 6632B, 6633B, 6631B, 6634B manual Specifications

Page 49

A

Specifications

Specifications

Table A-1 lists the specifications of the dc source. Specifications are warranted over the ambient temperature range of 0 to 55 °C. Unless otherwise noted, specifications apply when measured at the rear terminals after a 30-minute warm-up period.

Table A-1. Performance Specifications

Parameter

HP 6631B

HP 6632B HP 66332A

HP 6633B

HP 6634B

Output Ratings

Voltage:

0 8 V

 

 

0 20 V

 

0 50 V

 

0 100 V

 

 

 

Current:

0 10A

 

0 5A

 

 

0 2 A

 

 

0 1A

 

 

Programming Accuracy

Voltage:

0.05% + 5 mV

0.05% + 10 mV

0.05% + 20 mV

0.05% + 50 mV

± °

C)

+Current:

0.05% + 4 mA

0.05% + 2 mA

0.05% + 1 mA

0.05% + 0.5 mA

(@ 25C 5

 

 

 

 

 

 

 

 

 

 

 

 

 

DC Measurement

Voltage:

0.03% + 2 mV

0.03% + 3 mV

0.03% + 6 mV

0.03% + 12 mV

Accuracy

 

Low Current range

 

 

 

 

 

 

 

 

 

 

 

 

(via HP-IB or front panel

0.1% + 2.5

μ

1

0.1% + 2.5

μ

1

0.1% + 2.5

μ

1

0.1% + 2.5

μ

1

meters with respect to

20 mA to +20 mA:

 

A

 

A

 

A

 

A

High Current range

 

 

 

 

 

 

 

 

 

 

 

 

actual output at 25C

 

 

 

 

 

 

 

 

 

 

 

 

+20 mA to +rated I:

0.2% + 1 mA2

0.2% + 0.5 mA2

0.2% + 0.25 mA2

0.2% + 0.25 mA2

±5°C)

 

20 mA to rated I:

0.2% + 1.6 mA

0.2% + 1.1 mA

0.2% + 0.85 mA

0.2% + 0.85 mA

 

 

Ripple and Noise

Normal mode voltage

0.3 mV/3 mV3

0.3 mV/3 mV3

0.5 mV/3 mV3

0.5 mV/3 mV3

(in the range of 20 Hz to

(rms/p-p):

20 MHz with outputs

Fast mode voltage

 

 

 

 

 

 

 

 

 

 

 

 

ungrounded or with

(rms/p-p):

1 mV/10 mV

1 mV/10 mV

1 mV/15 mV

2 mV/25 mV

either terminal grounded)

Current (rms):

3 mA

 

 

2 mA

 

 

2 mA

 

 

2 mA

 

 

 

 

 

 

 

 

 

 

 

 

Load Regulation4

Voltage:

2 mV

 

 

2 mV

 

 

4 mV

 

 

5 mV

 

 

(change in output voltage

Current:

2 mA

 

 

1 mA

 

 

1 mA

 

 

1 mA

 

 

or current for any load

 

 

 

 

 

 

 

 

 

 

 

 

 

change within ratings)

 

 

 

 

 

 

 

 

 

 

 

 

 

Line Regulation

Voltage:

0.5 mV

 

 

0.5 mV

 

 

1 mV

 

 

1 mV

 

 

(change in output voltage

Current:

1 mA

 

 

0.5 mA

 

 

0.25 mA

 

0.25 mA

 

or current for any line

 

 

 

 

 

 

 

 

 

 

 

 

 

change within ratings)

 

 

 

 

 

 

 

 

 

 

 

 

 

Transient Response

Normal mode:

< 100 μs

 

 

 

 

 

 

 

 

 

 

 

Time4

 

Fast mode:

< 50 μs

 

 

 

 

 

 

 

 

 

 

 

(for the output voltage to recover to its previous level within 0.1% of the voltage rating of the unit or 20 mV following a change in load current of up to 50% of the output current rating)

1This specification may degrade slightly when the unit is subjected to an RF field 3 V/meter.

2Applies in SCPI mode, with current detector set to DC. With current detector set to ACDC, accuracy is 0.2% + four times the fixed error value. In COMPatibility mode, accuracy is 0.2% + six times the fixed error value.

3For HP 6631B, 6632B, and 66332A (from 1 MHz to 20 MHz ) = 0.3mV/15mV; For HP 6633B and 6634B (from 1 MHz to 20 MHz ) = 0.5mV/15mV

4Applies at rear terminals with unit set to remote sensing and with sense terminals externally jumpered to their respective output terminals.

Image 49
Contents USER’S Guide Certification Warranty InformationGeneral Safety SummarySafety Symbols EMC DeclarationPrinting History Acoustic Noise InformationTable of Contents Performing the Calibration Procedure Specifications Supplemental CharacteristicsEntry Keys Examples of Front Panel Programming IntroductionFlexible system features Convenient bench-top featuresQuick Reference Front Panel At a Glance Use the Function keys and Entry keys to enter a new value Front Panel Number EntryImmediate Action Keys Front Panel AnnunciatorsFront Panel Menus At a Glance ABORt SENSe CALibrate Scpi Programming Commands At a GlanceUse the front panel Address menu to Rear Panel At a GlancePage Document Orientation General InformationGetting Started Map Options and Accessories Safety ConsiderationsAccessories OptionsDescription Output Characteristic Cleaning InstallationInspection Damage Packaging MaterialBench Operation LocationRack Mounting Wire Considerations Connect the Power CordInput Connections Output ConnectionsVoltage Drops Remote Sense ConnectionsMultiple Load Connections Remote Sense Connections Sense LeadsStability OVP ConsiderationsPage Digital I/O Connections FLT/INH DIGital I/O ConnectorFLT/INH Examples HP-IB Interface Controller ConnectionsRS-232 Interface Pin Input/Output DescriptionTurn-On Checkout Using the KeypadIntroduction Procedure Display Explanation Checkout ProcedureCheckout Programming Values Model Voltage OV Prot CurrentPress 5, Enter Procedure Display ExplanationCase of Trouble Error MessagesLine Fuse Front Panel Description Front panel OperationRotary Control Display AnnunciatorsLine System Keys Function Keys Entry KeysSystem Keys Display Command FunctionImmediate Action Keys Function KeysScrolling Keys Display Measurement Metering KeysHigh LOWRST Output Control KeysOC OT OV RI FS Voltprot valueEntry Keys Entry KeysEnable the output Setting the Output Voltage and CurrentExamples of Front Panel Programming Set the output voltageMaking Front Panel Measurements Querying and Clearing Output ProtectionAction Currrang Auto Use the Meter menu for making front panel measurementsCurrdet Acdc To configure the Digio mode of the port, proceed as follows To configure the Ridfi mode of the port, proceed as followsProgramming the Digital Output Port Configure the RS-232 interface as follows Setting the HP-IB Address and RS-232 ParametersProgramming the Output Relay option 760 only Set the HP-IB address as followsSaving and Recalling Operating States Select the power-on state of the dc source as followsSave an operating state in location 1 as follows Recall a saved state as followsPage Specifications Table A-2. Supplemental Characteristics Supplemental CharacteristicsINH/FLT Characteristics Command ProcessingParameter HP 66332A Dynamic MeasurementDimensions Digital I/O CharacteristicsNet weight Shipping weightVerification and Calibration Test SetupEquipment Required Table B-1. Equipment RequiredPerforming the Verification Tests Figure B-1. Verification & Calibration Test SetupVoltage Programming and Measurement Accuracy Turn-On CheckoutCurrent Programming and Measurement Accuracy Table B-2. Verification Programming ValuesCurrent Sink Measurement Current Measurement Low RangeCurrrang LOW Current Programming and Measurement High Range Table B- 3. Verification Test Record for HP 6631BCurrent Measurement Low Range Current Sink MeasurementTable B- 6. Verification Test Record for HP 6634B Table B- 5. Verification Test Record for HP 6633BFront Panel Calibration Menu Performing the Calibration ProcedureFront Panel Calibration Enable Calibration ModeVoltage Programming and Measurement Calibration Overvoltage Protection CalibrationNegative Current Programming Calibration Current Programming and High-Range Measurement CalibrationLow-Range Current Measurement Calibration Table B- 7. HP-IB Calibration Error Messages Calibration Error MessagesError Meaning AC Current Measurement Calibration HP 66332A onlyCalibration Over the HP-IB Changing the Calibration PasswordCalpass Page Error Number List Error MessagesTable C-1. Error Numbers Error Messages Error Messages C Page Line Voltage Conversion Configure the Power TransformerOpen the Unit Close the Unit Install the Correct Line FuseIndex Index Index Japan United States of America EuropeAsia Pacific Latin AmericaManual Updates
Related manuals
Manual 94 pages 1.46 Kb

6631B, 6633B, 6634B, 6632B specifications

The HP 6632B, 6634B, 6612B, and 6633B are high-performance programmable power supplies that have gained prominence in various testing and measurement applications. These models are part of the HP 6000 series, which is renowned for its reliability and versatility in providing precision power supply solutions.

The HP 6632B offers a dual-output capability, delivering up to 32 volts and 3 amps per channel. It is designed for applications requiring stable and accurate voltage and current supplies. With features like overvoltage protection and short-circuit protection, it ensures the safety of both the device under test and the power supply itself. The programmable voltage and current settings allow operators to automate their testing procedures, increasing efficiency.

The HP 6634B takes performance a step further with multiple outputs, providing up to 32 volts and 5 amps per channel. This model is particularly suited for applications requiring higher current, especially in battery testing and device characterization. The ability to program the device remotely adds an extra layer of usability, making it ideal for integration into automated testing environments.

The HP 6612B model is tailored for users who require a compact and portable power supply solution. It delivers up to 20 volts and 2 amps. Despite its smaller size, it retains essential features like programmable settings and fast transient response, making it suitable for both educational purposes and field testing scenarios.

For users looking for a versatile, multi-channel solution, the HP 6633B presents itself as an excellent choice. This model offers up to 32 volts and 5 amps across multiple outputs. It supports a wide range of programmable features and has an intuitive interface, making it user-friendly for both beginners and experienced engineers. The robust design of the 6633B ensures reliable performance in demanding environments.

All four models utilize advanced linear power supply technology that minimizes ripple and noise, which is critical for sensitive electronic components. Together, these power supplies provide professionals in research, manufacturing, and testing with the precision they need for their experiments and product developments. The combination of programmability, safety features, and high-performance specifications makes the HP 6632B, 6634B, 6612B, and 6633B essential tools for electronic engineers and technicians.