HP 28642A manual Connect Your Peripheral Devices, Connect Your Single-Ended Scsi Devices

Page 28

Connect Your Peripheral Device(s)

You can connect SCSI devices(single-ended devicesonly) to the SCSI port, and a parallel communication device to the parallel port. (The parallel port is not supported for useon MPE XL systems.) The following stepsare describedbelow:

1.Connect your single-ended SCSI devices.

2.Terminate the SCSI bus.

3.Connect your parallel device (ii applicable).

4.Reassembleyour computer.

Connect Your Single-Ended SCSI Device(s)

When connecting SCSI devices,follow theseguidelines:

nVerily that the host systemis shut down. There should be no data transfer activity on the SCSI bus.

mVerify that power is off to the peripheral devicebefore connecting it to the SCSI bus.

nVerify that your peripheral devicesusesingle-endedSCSIbus signalsonly.

8Check whether your device contains internal SCSIbus terminators, or requires special terminators. If so, refer to your devicemanualsfor instructions on how to prevent excessiveor improper SCSIbus termination.

CAUTION

Only the two endsof a SCSIbus should be terminated. Excessiveor

 

improper termination may overload the SCSI port’s termination power

 

(“TERMPWR”) circuitry. This mayresult in blowing the TERMPWR

 

fuse on the adapter, or damagingtransceiverson any attached device

 

(including the adapter). Refer to device manualsto ensurethey operate

 

properly on the SCSIbus.

Installing the Adapter l-19

Image 28
Contents HP 28642A HP-PB Scsi HP 28655A HP-PB SCSI/ Parallel HP HP 5960-3126 El091@Hewlett-Packard Company, 1991. AI1rights rcservcd Safety ConsiderationsPrint History Installation and S&vice HP 28642A and HP 28655A at a Glance Product Description This Book Table of Contents Page Installing HP 28642A/28655AAdapter Lnstalllng the HP 28642A/28655A Adapter Observe Antlstatic Precautions Prepare to Install the Adapter CardVerify Product Contents Gather Tools and Accessories Needed Record Adapter Card Identification InformationPeripheral to 92222A Dependent requirements that are not noted hereTable l-l. Scsi Cables LengthsDescription meters Data corruption Installing the Adapter Shut Down the System and SwZtch Off the ComputerRemove CreateCheck the Card’s Hardware Configuration Figure l-4. Default Switch Settings Installing the Adapter Set the Desired Parity-Checking CapabUity= closed = open Installing the Adapter l-9 Set the Scsi Bus AddressScsi Bus AddressVerify that Resistor Packs are Properly Installed Two resistor packsmust be installedInstall and Connect the Card Select an Appropriate SlotHP-Pa Standard Power Symbol Computer hardware limitations for l/O cards, if any Record the Slot NumberSystemperformance implications, if any Prepare the Slot For Use Ignment Hole Page Card guides. If the problem persists,get help Insert the Card into the SlotSupplied with this product provides a thumbscrew connector Attach the Card CablesInstalling the Adapter l-19 Connect Your Peripheral DevicesConnect Your Single-Ended Scsi Devices Properly on the SCSIbusTerminate the Scsi Bus Device operation on the SCSIbus 12. Scsi Bus Example Installing the Adapter Scsi Cable Length ExampleTurnPowerOn to Peripherals, Then to the Computer Connect Your Parallel Device, If ApplicableReassemble your computer Two meters24Installing the Adapter Signal NameIn/Out Pin25 Turn Power On to Peripherals, Then to the Computer Data corruption or loss,or damageto hardwareHP-UX Systems Set Up the Operating SystemMPE XL Systems Verify Operation ServiceInformation Service Information Exchange Assembly Exchange adapter card assemblyField Replaceable Units Flgure 2-1. Location of Board Component FRUsBoard Components Other FRUsShould be performed by authorized servicepersonnel only Troubleshooting ToolsSelf-lestFailure Self-Test Failure LED Boot failure occursOperation. Refer to your systemreference manuals Scsipba and Centpba Diagnostics Troubleshooting ChecklistDoes any device require a special SCSIterminator? Removal/Replacement Instructions Removal/Replacement of the Card For card removal, follow the procedures belowRemoval/Replacement of Card Components Minimize touching the connector pinsAlso be determined from the,scsipbadiagnostic Service Information 2-lDamagewasextensive, you may need a new component Type and ratingFlgure 2-3. Replacing the Termpwr Fuse Service Information DiagnosticCan continue to operate normally Reshipment Guidelines General Technical Specifications1green IElectrical +5 Vdc IPhysical IEnvironmentalGlossary ConfigurationAmerican National StandardsInstitute Backplane FRU Host adapter Seeadapter HP-PBParallel port Complies with the Scsi specification X3.131 GlossaryPrecision Bus See HP-PB SCSI-2 Termination Index Index tCable Card version...14Identification information...l-4 installing Part number...2-3 Field replaceable units se-eFRUSFRUs...2-3 HP Precision Bus SeeHP-PB HP-PBPhysical specifications...2-16 Index Loopback hood...2-4Power Product contents...13Resistor pack...&10 Self-test failure LED...2-6 shut downStoring adapter cards...l-3 switch During installation/removal..J-6,1-19,2-10Troubleshooting..2-8 Ylrlbo~5960-3126 El091