HP 28642A manual Fru

Page 55

device

In this manual, refers to the peripheral units that are attachedto the SCSI/parallel adapter card.

device adapter

Seeadapter.

differential signal

Also referred to as“balancedsignal”. During electrical transmissionand reception, signalsare detemined by the difference betweentwo lines that are both at different voltagesrelative to ground. Differential SCSIsignalscanbe usedover longer distancesand at higher data rates. A differential SCSIbus is incompatible with a single-ended SCSI bus. Therefore, differential SCSIdevicesmay not be usedwith the SCSI/parallel adapter card. Seealso, single-endedsignal.

filler card

In someHP-PB computers, a removable plastic plate that is installed in HP-PB I/O slots when the slot is not in use.

FRU

Field Replaceable Unit. The lowest level of hardwaresupported for field replacement, such as to effect repair.

hardware path

The collection of hardware addressesthat uniquely identify hardware elements (such asadapter cards and peripheral devices) to the computer system.

high-density connector

In reference to the adapter card’s SCSI port, a 50-conductor connector consisting of two rows of 25 contacts with adjacent contacts 1.27mm (0.05in) apart. Seealso, low-density connector.

host

In this manual, the computer in which the adapter card is installed.

2 Glossary

Image 55
Contents HP 28642A HP-PB Scsi HP 28655A HP-PB SCSI/ Parallel 5960-3126 El091 HP HP@Hewlett-Packard Company, 1991. AI1rights rcservcd Safety ConsiderationsPrint History Installation and S&vice HP 28642A and HP 28655A at a Glance Product Description This Book Table of Contents Page Installing HP 28642A/28655AAdapter Lnstalllng the HP 28642A/28655A Adapter Observe Antlstatic Precautions Prepare to Install the Adapter CardVerify Product Contents Record Adapter Card Identification Information Gather Tools and Accessories NeededPeripheral to 92222A Dependent requirements that are not noted hereTable l-l. Scsi Cables LengthsDescription meters Create Data corruption Installing the AdapterShut Down the System and SwZtch Off the Computer RemoveCheck the Card’s Hardware Configuration Set the Desired Parity-Checking CapabUity Figure l-4. Default Switch Settings Installing the AdapterAddress = closed = open Installing the Adapter l-9Set the Scsi Bus Address Scsi BusTwo resistor packsmust be installed Verify that Resistor Packs are Properly InstalledSelect an Appropriate Slot Install and Connect the CardHP-Pa Standard Power Symbol Computer hardware limitations for l/O cards, if any Record the Slot NumberSystemperformance implications, if any Prepare the Slot For Use Ignment Hole Page Insert the Card into the Slot Card guides. If the problem persists,get helpAttach the Card Cables Supplied with this product provides a thumbscrew connectorProperly on the SCSIbus Installing the Adapter l-19Connect Your Peripheral Devices Connect Your Single-Ended Scsi DevicesTerminate the Scsi Bus Device operation on the SCSIbus Scsi Cable Length Example 12. Scsi Bus Example Installing the AdapterTwo meters TurnPowerOn to Peripherals, Then to the ComputerConnect Your Parallel Device, If Applicable Reassemble your computer24Installing the Adapter Signal NameIn/Out Pin25 Data corruption or loss,or damageto hardware Turn Power On to Peripherals, Then to the ComputerHP-UX Systems Set Up the Operating SystemMPE XL Systems Verify Operation ServiceInformation Service Information Flgure 2-1. Location of Board Component FRUs Exchange AssemblyExchange adapter card assembly Field Replaceable UnitsOther FRUs Board ComponentsShould be performed by authorized servicepersonnel only Troubleshooting ToolsSelf-lestFailure Self-Test Failure LED Boot failure occursOperation. Refer to your systemreference manuals Troubleshooting Checklist Scsipba and Centpba DiagnosticsDoes any device require a special SCSIterminator? Removal/Replacement Instructions For card removal, follow the procedures below Removal/Replacement of the CardService Information 2-l Removal/Replacement of Card ComponentsMinimize touching the connector pins Also be determined from the,scsipbadiagnosticType and rating Damagewasextensive, you may need a new componentFlgure 2-3. Replacing the Termpwr Fuse Service Information DiagnosticCan continue to operate normally Reshipment Guidelines General Technical Specifications1green IPhysical IEnvironmental IElectrical +5 VdcGlossary ConfigurationAmerican National StandardsInstitute Backplane FRU HP-PB Host adapter SeeadapterParallel port Complies with the Scsi specification X3.131 GlossaryPrecision Bus See HP-PB SCSI-2 Termination Index t IndexCard version...14 CableHP Precision Bus SeeHP-PB HP-PB Identification information...l-4 installingPart number...2-3 Field replaceable units se-eFRUS FRUs...2-3Loopback hood...2-4 Physical specifications...2-16 IndexSelf-test failure LED...2-6 shut down PowerProduct contents...13 Resistor pack...&10Ylrlbo~ Storing adapter cards...l-3 switchDuring installation/removal..J-6,1-19,2-10 Troubleshooting..2-85960-3126 El091