Roberts Gorden HP 230 V 3, HP 208 V 1 120 60 Hz, Outside Air Blower External Wiring Diagram

Page 16

SYSTEM CONTROL INSTALLATION, OPERATION AND SERVICE MANUAL

FIGURE 8: External Wiring Diagram ROBERTS GORDON® EP-100 or EP-201 120 V 1 Ø Pump with Out- side Air Blower

Outside Air

Pump

Blower

 

 

 

 

 

 

 

 

 

 

 

 

120 V

 

120 V

 

1 Ø

 

1 Ø

 

60 Hz

 

60 Hz

 

 

 

 

L

 

 

 

N

 

 

Ground

 

 

 

G

N

L

N L

 

POWER

PUMP 1

 

SUPPLY

 

Optional power supply for Outside Air Blower

Typical wiring for Load Relay

Package (P/N 05023000)

Live out to the

Coil connections

to Pump L & N

outside air

Outputs from

blower

Control Panel

 

Outside Air

 

 

Blower

 

 

Live in

3

Coil

6

 

2

5

 

1

4

 

 

Coil

Relay Receptacle

Back Plate

CR

120 V

L

1 Ø

N 60 Hz

 

Pump

TWO PUMP SYSTEM (optional)

 

 

Pump 1 may be used for all zones.

 

 

 

 

 

 

Pump 2 may be used to control zone 3

 

 

 

and/or zone 4. Refer to Pump 1 for configuration.

 

 

Pressure switch

Pressure switch located

All burners must be

 

located at pump 2

at outside air blower

connected to Ground

 

 

 

 

 

(Not shown)

 

 

 

 

 

Zone 1 Zone 2 Zone 3 Zone 4

 

 

 

 

 

 

 

Pressure switch

Pressure switch

 

 

located at pump 1

located at outside air

 

 

 

 

blower

 

 

 

Low voltage thermostats

 

 

 

located in heated zone

 

 

Zone

Zone

Zone

Zone

 

 

1

2

3

4

24 VAC

 

 

 

 

24 VAC PS 1

R

R

R

R

PS 2

N L

N L

N L

N L

N L COM

 

 

 

 

 

Z1

Z2

Z3

Z4

PUMP 2

 

 

 

 

 

 

 

 

 

24 VAC PS 1

W

W

W

W

PS 2

 

 

 

 

COM

 

 

 

 

 

System Control

4.4 Outside Air Blower External Wiring Diagram

The external wiring diagram above shows the con- nections for four zones of system burners. System burners can be either CORAYVAC® or VANTAGE® NP (multiburner only).

The zones are connected to a single pump, unless zone 3 and/or zone 4 are selected to function with the optional pump 2. The external wiring diagram above shows connection to an EP-100 or EP-201 1 Ø motor. The diagram also shows the connection via a

10

Image 16
Contents System Control Page Roberts-Gordon LLC Page Table of Figures Page What is a Roberts Gordon System Control? Introduction 1.1 SafetyCheck Installation Materials Page Specifications Pump Specifications Electrical SpecificationsOutside Air Supply Blower Electrical Ratings Burner Electrical RatingsTerminal Block Guide Installation Installing the System Control PanelSelect the External Wiring Diagram for the Installation PreparationSystem Configuration Typical External Wiring Diagrams System ControlEP-201 or EP-301 230 V 1 Ø External Wiring Diagram208 230 V or 460 60 Hz EP-203 or EP-303 208 230 V or 460 V 3 ØOutside Air Blower External Wiring Diagram 120 60 HzTypical External Wiring Diagrams Troubleshooting System Control Troubleshooting Chart Replacement Parts System Control Internal Components DiagramSee Page 14, , Item Page ROBERTS-GORDON will not PAY for Warranty is Void ifLimitations on Authority Representatives