Roberts Gorden CTU 22 TO 115 service manual Product Approval

Page 7

Product Approval

ROBERTS GORDON® appliances have been tested and CE certified as complying with the essential requirements of the Gas Appliance Directive, the Low Voltage Directive, the Electromagnetic Compatibility Directive and the Machinery Directive for use on natural gas and LPG when installed, commissioned and maintained in accordance with these instructions.

These instructions refer to appliances designed to operate in the European Union. Appliances designed for other countries (Non-European Union) are available on request.

This appliance must be installed in accordance with the local and national codes in force and used only in a sufficiently ventilated space, as specified in these instructions.

Before installation, check that the local gas distribution systems, nature of gas and pressure, and adjustment of the appliance are compatible.

1

Image 7
Contents Supplier, call the Fire Department Immediately call your local gasSupplier after leaving the building Follow the gas supplier’s InstructionsPage Roberts-Gordon, LLC Page Table of Figures Page Product Approval Corrosive Chemicals Heater SafetyInstaller Responsibility Clearances to CombustiblesGas Supply Minimum Required Installation ClearancesCritical Considerations 3.1 Basic Information VentilationInstallation Clearances and Clearances to Combustibles End View Rear View Specifications 4.1 CtuaDimension Data Ctua All Models Top ViewCTUB, Ctuc and Ctud Dimension Data CTUB, Ctuc and CtudGeneral Technical Data Table Gas rates corrected to standard conditions 1013.25 mbar 15 C Handling Heater Installation 5.1 GeneralType B22 Appliance Flue Installation 6.1 Flue InstallationAir Intake Terminal Cover Vertical and Horizontal Flue Termination Type B22 Appliance AIR Supply Distribution Duct Work for CTUB, Ctuc and Ctud Heaters Optional Heater ConfigurationsCtud Heaters Option B GAS PipingConnections Option aWiring and Electrical Information 50 Hz Ctua Wiring Diagram ModelsSite Wiring CTUB/C Wiring Diagram Models Site Wiring230 V 1 Ø 50 Hz Ignition ModuleRUN For external fan wiring Ctud Wiring Diagram ModelsSite Wiring and Electrical Information Mechanical Checks CommissioningLouvres Electrical ChecksEnd View Automatic Burner Control Box SequenceCheck Gas Rate Combustion TestingTurning Off the Heater Complete the Commissioning External ControlsInstruction to the User Lighting Instructions To Turn On Heater Burner Lockout Reset ButtonHeater Operation Common User Controls Thermostat Limit ThermodiscSimple Fault Finding Burner Faults Simple Fault FindingTo Turn the Heater Off Gas Control Valve Maintenance Burner Maintenance13.3 Fan/Motor Assembly Maintenance Heat Exchanger MaintenanceBurner Conversion Conversion Between Gases 14.1 GeneralGas Valves Start Conduct Commissioning procedure as shown on Page 24, SectionFor your safety and optimum heater performance Troubleshooting For Automatic Ignition Burner SystemsConduct Commissioning procedure as shown Troubleshooting for Solenoid Valves Troubleshooting for Flame Supervision SystemRemoval and Replacement Parts Burner Injectors Burner CompartmentIgnition Electrode and Flame Probe Remove screws securing outlet flange to the flue adapter RG P/N Pressure SwitchCtub & Ctuc Centrifugal Fan/Guard/Motor Assembly Ctua Axial Fan/Guard/Motor AssemblyFan Removal and Replacement To Replace the Fan AssemblyFan Data Centrifugal Fan OrientationPage Page Page Some objects can catch fire or explode when placed

CTU 22 TO 115 specifications

The Roberts Gordon CTU 22 TO 115 is a renowned unit heater designed to deliver efficient heating solutions in commercial and industrial settings. Known for its advanced features and robust design, this unit heater is ideal for applications where warmth and comfort are essential, such as warehouses, manufacturing facilities, and large retail spaces.

One of the main features of the CTU 22 TO 115 is its powerful heating capacity. With a range of output capabilities, it can effectively heat large areas, ensuring that employees and equipment remain comfortable during cold weather. The heater's output is adjustable, allowing for tailored heating solutions based on specific operational needs.

This model integrates several innovative technologies to enhance efficiency and performance. The use of advanced combustion technology ensures optimal fuel efficiency, which translates to lower energy costs and reduced environmental impact. The heater is available in both gas and oil configurations, providing versatility to accommodate different fuel sources depending on availability and preference.

In addition to its energy efficiency, the Roberts Gordon CTU features a compact design, making it suitable for installations in tight spaces. Its lightweight construction allows for easy installation and relocation, ensuring that businesses can quickly adapt to changing layout requirements. The unit is equipped with high-quality materials and a durable finish, contributing to its longevity and low maintenance needs.

Safety is a paramount concern in any heating system, and the CTU 22 TO 115 doesn't disappoint. It comes with various safety features, including over-temperature protection, ensuring that it operates securely under all conditions. With automatic shutoff capabilities, the heater provides peace of mind to operators, allowing for unattended operation in more remote settings.

Moreover, the CTU’s quiet operation is a significant advantage, as it minimizes disruption in the workplace, ensuring a comfortable environment for personnel. Its design also facilitates easy access to components for maintenance, thus ensuring that the unit remains operational with minimal downtime.

Overall, the Roberts Gordon CTU 22 TO 115 combines performance, efficiency, and safety features to create a reliable heating solution for diverse industrial applications. Its adaptability to various fuel types and efficient design makes it a popular choice among facility managers looking for dependable heating solutions.