Module Problems

Table 4-5. Channel Loopback Errors

 

Error Messages

Corrective Action

 

Slot is not busied-out

Exit the test, busy-out the slot, and try again.

 

 

 

 

 

 

Slot

empty or not valid

Exit the test and try again; be sure to type the correct

 

 

 

slot number. Do not indicate an empty slot or the

 

 

 

processor (00).

 

 

 

 

 

FMWR not in Standby Mode

Exit the test and try again; if this error persists, record

 

 

 

the errors on the repair tag and replace the module

 

 

 

being tested.

 

 

 

 

 

 

Test

running too long

Exit the test and try again; if this error persists, record

 

 

 

the errors on the repair tag and replace the module

 

 

 

being tested.

 

 

 

 

 

 

Not

in TEST/STANDBY mode

Exit the test and try again; if this error persists, record

 

 

 

the errors on the repair tag and replace the module

 

 

 

being tested.

 

 

 

 

 

Any other error

Record the errors on the repair tag and replace the

 

 

 

module.

 

 

 

 

 

Restoring the Module

When you are finished running module tests, be sure to restore the module. See "Restore” earlier in this chapter for instructions.

Replacing Modules

You can remove and insert line/trunk and extension modules (separately or at the same time) with the system power on without affecting normal call processing.