AT&T 3.0 manual 840D Incorrect Firmware State

Models: 3.0

1 608
Download 608 pages 29.49 Kb
Page 363
Image 363

Error Logs

Table 2-2 Continued

Error

Codes Description

Action

840B NO LOOP CURRENT: communication problems between

the module and the central office. No loop current.

If this error occurs 4 times consecutively, and if Automatic Maintenance-Busy is enabled and the 50% maintenance-busy limit has not been exceeded, the trunk is busied-out automatically.

Replace the module with a similar module and test, If the problem is resolved, replace the bad module. If the problem persists, reinstall the old module and test the trunk.

840C

STUCK RINGING:

 

 

 

Replace the module with a similar

 

Communication

problems between

module and test. If the problem is

 

the module and

central office.

resolved, replace the bad module. If the

 

If this error occurs four times

problem persists, reinstall the old module

 

consecutively, and

if

Automatic

and test the trunk.

 

Maintenance-Busy

is

enabled and

 

the 50% maintenance-busy limit has not been exceeded, the trunk is busied-out automatically.

840D INCORRECT FIRMWARE STATE:

If this error occurs 4 times consecutively, and if Automatic Maintenance-Busy is enabled and the 50% maintenance-busy limit has not been exceeded, the trunk is busied-out automatically.

Turn power off for at least 1 second and then turn it on. Repeat system programming procedure. If problem persists, replace the module.