AT&T 3.0 manual Reviewing the Access Log

Models: 3.0

1 608
Download 608 pages 29.49 Kb
Page 364
Image 364
(M).

Access Log

 

Table 2-2 Continued

 

 

 

 

 

Error

 

 

 

 

Action

 

Codes Description

 

 

840E

UPLINK MESSAGE ERROR:

 

Turn the processor off and then on.

 

 

 

Communication problems

between

Repeat system programming procedure.

 

 

 

the processor and the modules. The

If the problem persists, replace the

 

 

 

module

received an unrecognized

module.

.

 

 

message

from the processor.

 

 

 

 

 

 

 

 

 

 

 

 

8C01

SLOTS NOT EQUAL:

 

Troubleshoot the slot descriptions in

 

 

 

The module that occupies the

your backup file against the actual

 

 

 

indicated slot does not match the

system modules that occupy those

 

 

 

slot

information contained

in the PC

slots. After the mismatch is corrected,

 

 

 

or

PCMC1A card backup

file.

repeat the restore operation.

 

 

 

 

 

 

 

 

 

 

Access Log

In addition to checking the error logs, you can check the access log to help you troubleshoot. Each time maintenance or system programming is accessed, the event is recorded in an access log (up to the last 20 events), This information may be useful in determining whether one of those events caused an error detected shortly thereafter.

Reviewing the Access Log

Each event is documented by the time and date of occurrence, The station button (Sta) column indicates whether the event occurred from an MLX-20L console (if so, the extension number is displayed) or from SPM (SPMD if direct; SPMR if remote). The SP/M column indicates whether the event originated from System Programming (SP) or Maintenance

2-18Error Logs, Access Logs, and System Inventory

Page 364
Image 364
AT&T 3.0 manual Reviewing the Access Log