Installing Direct Station Selectors

bConnect one end of the D6AP cord to the 2-conductor (small) modular jack on the 400B or 400B2 adapter, and plug the other end of the D6AP cord into the modular jack of the 406943837 or 406743419 power supply.

CAUTION:

Do not plug the D6AP cord into the 8-conductor (large) modular jack of the 400B or 40052 adapter. Doing so can cause electrical damage to the control unit and to the telephone.

cInsert the plug end of the 4008 or 400B2 adapter into the wall jack.

dPlug the power supply into a 117-V AC outlet.

9 Label the DSS designation cards.

aPull the tab at the top of the large plastic cover and rotate the cover towards you.

bRemove the cover and the large designation card.

cWrite or type the button assignments on the card, (For DSS1, use the side that is labeled 00-49for DSS2, use the side labeled 50-99.)

The button assignments on the designation card should be by dial plan extension number, not by logical ID port number.

dReplace the card and the plastic cover; make sure the coated side of the cover is facing up.

eRepeat this step to remove the small plastic cover and to label the small designation card.

NOTE:

If the MLX telephone attached to the DSS is unplugged from the control unit and then plugged in again, the display on the telephone may disappear, Press the Home button to bring back the display.