AT&T 3.0 manual 7500B Data Module and CSU Settings, B Data Module Settings Kbps

Models: 3.0

1 608
Download 608 pages 29.49 Kb
Page 205
Image 205

Video Conferencing Data Stations

7If it is not already connected, connect the CSU to the 100D module on the control unit and to the 5ESS or 4ESS exchange switch,

See “lnstalling the Channel Service Unit” in Chapter 4.

8When you are ready to power up the system, plug the power supplies, CSU, video conferencing equipment, and control unit into the AC outlets.

7500B Data Module and CSU Settings

You need to set the 7500B data modules and the CSU as indicated in Table 6-2. If the customer’s system is running at 56 kbps, set the CSU line-coding DIP switches according to the instructions in “Setting the CSU DIP Switches” in Chapter 4.

Table 6-2. 7500B Data Module Settings

Settings

56 Kbps

64 Kbps

Auto-dial

Off

Off

Busy out

Off

Off

Datarest

On

Off

DTR

Follow

Follow

 

 

 

Duplex

Full

Full

Mode

Cs

Cs

Speed

56,000

64,000

6-20Connecting Data Equipment