AT&T 3.0 manual Interpreting Test Results, Screen below appears only if the test fails

Models: 3.0

1 608
Download 608 pages 29.49 Kb
Page 434
Image 434

Module Problems

The screen below appears only if the module passes the test.

Console Display/Instructions

Additional Information

P C

BchLoopback

Slot xx:

 

xx = slot number entered in Step 2

 

BchLoopback

 

 

 

 

Passed

 

 

Exit

The screen below appears only if the test fails.

 

BchLoopback Slot xx:

xx = slot number entered in Step 2

 

BchLoopback Failed

 

 

xxxxxxxxxxxxxxxxxxxxxxxx

 

 

xx xx xx xx xx xx xx xx

 

Exit

Lines 3 and 4 identify the cause of the failure or the number of errors found per B-channel. There are 16 B-channels, numbered 0 through 15. Line 3 displays the results for B-channels 0 through 7; Line 4 is for B-channels 8 through 15.

Interpreting Test Results

If the test completes successfully, the module’s B-channels are functioning properly. Continue with the next module test or restore the module if you are finished testing. If the test fails, find the error message in Table 4-5and proceed as indicated.