AT&T 3.0 manual 100D Module Problems, Upgrade Attempted on an Empty Slot

Models: 3.0

1 608
Download 608 pages 29.49 Kb
Page 448
Image 448

100D Module Problems

Upgrade Attempted on an Empty Slot

Console Display/Instructions

Additional Information

PC

Upgrade Slot xx: No module in slot.

xx = slot selected in Step 3.

Exit

Select Exit and repeat the upgrade procedure, being careful to select the correct slot.

Board Memory Programming Failure

Upgrade Slot xx:

Board Memory Programming

Failure.

Upgrade CANCELED. Upgrade INCOMPLETE.

xx= slot selected in Step 3.

Exit

Repeat the upgrade procedure. If the upgrade continues to fail after several attempts, the module should be replaced. See “Replacing the Module.

100D Module Problems

The 100D module requires the CSU Loopback Test, in addition to the other module tests, See Figure 4–6for a diagram of the entire module testing process. If you have any questions about the 100D module that this section does not cover, contact your technical support organization.

4-70Control Unit Problems

Page 448
Image 448
AT&T 3.0 manual 100D Module Problems, Upgrade Attempted on an Empty Slot, Board Memory Programming Failure