Installing the Modules

E&M Mode

—Type 1 Standard (default factory setting). This setting is used to connect two systems through telephone company facilities.

—Type 1 Compatible. This setting connects two systems directly (without using telephone company facilities).

Simplex Mode

—Type 5. This setting is used on 4-wire (2-pair) circuits.

400EM (Tie Trunk) Module DIP Switches

During installation of 400EM (Tie Trunk) modules, refer to Table 2-4 and Table 2-5,and to Figure 2-11for the correct DIP switch settings for varying signaling protocols.

Table 2-4. Setting the 400EM (Tie Trunk) Module DIP Switches

 

 

Ports

D I P

Signaling Type

 

 

 

(as numbered in

 

 

 

 

 

 

 

Switch

1S (Default)

 

 

 

 

 

Figure 2-11)

Position

and 1C

1C and 1S

 

5

 

 

 

 

 

 

Unprotected

Protected

 

Simplex

 

 

 

 

 

E&M Mode

E&M Mode

 

Mode

 

 

 

 

1

ON

OFF

 

OFF or ON

2

 

4

2

ON

OFF

 

OFF or ON

 

3

OFF

OFF

 

ON

 

 

 

 

4

OFF

OFF

 

ON

 

 

 

 

5

OFF

OFF

 

ON

 

 

 

 

6

ON

OFF

 

OFF or ON

1

 

3

7

ON

OFF

 

OFF or ON

 

8

OFF

OFF

 

ON

 

 

 

 

9

OFF

OFF

 

ON

 

 

 

 

10

OFF

OFF

 

ON

 

 

 

 

 

 

 

 

 

 

Installing the Control Unit 2-35

Page 66
Image 66
AT&T 3.0 manual 400EM Tie Trunk Module DIP Switches, Simplex Mode