AT&T 3.0 manual Unit Load Worksheet

Models: 3.0

1 608
Download 608 pages 29.49 Kb
Page 279
Image 279

Unit Load Calculation Worksheet

Unit Load Worksheet

1.Number of modules in carrier (excluding power supply and processor:

If fewer than five, auxiliary power is not required.

If five or six, continue to Step 2.

2.Key or Behind Switch mode only:

Indicate configuration of lines; then go to Step 5.

3. Hybrid/PBX mode only:

Do all modules in the carrier have MLX and/or analog multiline telephone jacks?

If no, auxiliary power is not required

If yes, continue to Step 4.

4.Hybrid/PBX mode only:

Calculate the total number of MLX and analog multiline telephones:

Number of MLX-20L consoles connected to modules in the carrier

Number of MLX-28D consoles connected to modules in the carrier

Number of 34-button analog multiline telephones connected to modules in the carrier

Total of MLX-20L, MLX-28D, and 34-button analog telephones

If total is less than or equal to 45, auxiliary power is not required.

If the total is greater than 45, continue to Step 5.

Square

Modified

Yes

No