Error Logs

Table 2-2 Continued

 

 

 

 

 

Error

 

 

 

Action

 

 

 

Codes

Description

 

 

7806

NOT IN STANDBY MODE:

Reset the board. If problem persists,

 

 

 

 

 

Reported during cold start or

troubleshoot the module.

 

 

 

 

 

background check.

 

 

 

 

 

 

 

 

7807

SELF TEST NOT COMPLETER

Reset the board. If problem persists,

 

 

 

 

 

Reported

during cold start.

troubleshoot the module.

 

 

 

 

 

 

 

7808

TEST RESULT REGISTER BAD:

Reset the board, If problem persists,

 

 

 

 

 

A module error or processor error

troubleshoot the module.

 

 

 

 

 

resulted while

running test.

 

 

 

 

 

 

 

7809

TEST STATUS REGISTER BAD:

Reset the board. If problem persists,

 

 

 

 

 

A module error or processor error

troubleshoot the module.

 

 

 

 

 

resulted while

running test.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

780A

DPR TEST

NOT

COMPLETED:

If problem persists, troubleshoot the

 

 

 

 

 

Reported

during cold start.

module.

 

 

 

 

 

 

 

 

 

 

 

 

780C

RAM TEST

FAILURE:

If problem persists, replace the

 

 

 

 

 

Memory failed the RAM test. Turns

processor.

 

 

 

 

 

on the processor LED.

 

 

 

 

 

 

 

 

 

 

 

 

780D

UPPER ROM FAILURE:

If problem persists, replace the

 

 

 

 

 

Memory failed the ROM test. Turns

processor.

 

 

 

 

 

on the processor LED.

 

 

 

 

 

 

 

 

 

 

 

780E LOWER ROM FAILURE:

Memory failed the ROM test. Turns on the processor LED.

If problem persists, replace the processor.

Continued on next page

2-14Error Logs, Access Logs, and System Inventory

Page 360
Image 360
AT&T 3.0 manual Not in Standby Mode