Integrated Solution Ill

The following hardware is also required:

A 355AF adapter for connecting the Master Controller to the serial port on the control unit if they are within 50 ft. (15.2 m) of each other and are on the same AC branch circuit

ADUs for connecting the Master Controller to the serial port on the control unit, if they are not within 50 ft. (15.2 m) of each other and/or they are not on the same AC branch circuit

Any additional hardware required by the individual applications included in IS Ill, including the cables and adapters for connecting the applications to the system

IVP4 boards or IVP6 cards for AUDIX Voice Power and FAX Attendant

012 basic telephone module to provide the tip/ring interface for AUDIX Voice Power

TR114 boards for FAX Attendant

A summary of the installation procedure is provided below:

1Setup the equipment and identify the hardware for IS III.

2 Connect the hardware as shown in the instructions.

3 Install the software and test the IS III application.

If a voice application is installed, you will need two 125-MB tape cartridges for system backup.

For more information, consult Integrated Solution Ill Installation and Maintenance Guide.

Installing Applications 8-15