Error Logs

Table 2-2 Continued

 

 

 

 

 

 

Error

 

 

 

 

 

 

 

 

Codes

Description

 

 

Action

 

 

 

8401

MISCELLANEOUS ERROR:

 

NO action required.

 

 

 

 

currently

not

reported.

 

 

 

 

 

 

 

 

 

 

8402

WINK TOO

SHORT:

 

Troubleshoot the far end of the network

 

 

 

 

Outbound

dialing problems on

tie

interface to see if it is working and

 

 

 

 

trunks. For

a tie trunk with delay

dial or

translated properly. Troubleshoot for

 

 

 

 

wink start, the wink from the far end of

faulty cable. Replace the module.

 

 

 

 

 

 

 

 

 

the network interface is less than the

 

 

 

 

 

minimum 100 ms. The tie trunk

 

 

 

 

 

remains waiting for a valid signal.

 

 

 

 

 

 

8403

NO EXTERNAL RELEASE:

 

Troubleshoot the far end of the network

 

 

 

 

Communication problems between

interface to see if it is working and

 

 

 

 

the module and central office. Far end

translated properly, Troubleshoot for

 

 

 

 

has not disconnected within 4

 

faulty cable.

 

 

 

 

minutes.

 

 

 

 

 

 

 

 

If this error occurs twice

 

 

 

 

 

 

consecutively, the trunk is busied-out

 

 

 

 

 

automatically,

whether Automatic

 

Maintenance-Busy is enabled or not.

8404 ON HOOK BEFORE WINK:

Outbound dialing problems on tie trunks, For a tie trunk with delay dial or wink start, the far end of the network interface went on-hook before the handshake was completed.

If problem persists, troubleshoot the tie trunk configuration. Troubleshoot the far end to see if it is working and translated properly. Troubleshoot for faulty cable. Replace the module.

Continued on next page

Error Logs, Access Logs, and System Inventory 2-15

Page 361
Image 361
AT&T 3.0 manual Miscellaneous Error