Unit Load Calculation Worksheet

6. Calculate the actual carrier unit load,

 

Qty x

Unit Load

 

= Total

 

 

 

 

 

 

 

 

Hybrid/PBX or

 

 

 

 

Equipment

Modified

Square

 

 

 

 

 

 

 

 

 

Network Access Lines*

 

 

 

 

 

DID

1.0

1.0

 

 

 

DS1

0.0

0.0

 

 

 

GS/LS

0.0

0.0

 

 

 

Tie

1.4

1.4

 

 

 

Telephones

0.9

1.2

 

 

 

MLX-10

 

 

 

MLX-10D

0.9

1.2

 

 

 

MLX-28D

1.2

1.7

 

 

 

MLX-20L

1.1

1.6

 

 

 

BIS-10

0.9

1.1

 

 

 

BIS-22

1.0

1.3

 

 

 

BIS-22D

1.0

1.3

 

 

 

BIS-34

1.1

1.5

 

 

 

BIS-34D

1.1

1.5

 

 

 

MLC-5

0.0

0.0

 

 

 

MDC-9000

0.0

0.0

 

 

 

MDCW-9000

0.0

0.0

 

 

 

10-Button Basic

0.9

1.1

 

 

 

10-Button HFAI

1.0

1.2

 

 

 

34-Button Basic

0.9

1.1

 

 

 

34-Button DLX

1.2

1.7

 

 

 

34-Button BIS

1.2

1.4

 

 

 

34-Button BIS/DIS

1.2

1.4

 

 

 

Single-Line Telephone

0.6

0.7

 

 

Continued

* Unit loads are computed per trunk for trunk-type network access lines.