AT&T 3.0 manual Auditing DS1 PRI B-Channels, Auditing Lines Summary

Models: 3.0

1 608
Download 608 pages 29.49 Kb
Page 495
Image 495

Checking Ports

Auditing DS1 PRI B-Channels

The Auditing Lines and Auditing Calls procedures initiate an audit. Once an audit is initiated, you need to wait for the far end to send a message, which usually takes about four minutes. After waiting four minutes, check the error logs to see if any new PRI errors have occurred.

Auditing Lines. If troubleshooting indicates problems with PRI lines between the control unit and the CO, this audit, if successful, fixes the problem. It allows either side of the PRI interface to synchronize both ends by exchanging messages.

Auditing Calls. If troubleshooting indicates problems with PRI calls to or from MLX telephones, this audit, if successful, fixes the problem. It allows either side of the PRI interface to synchronize both ends by exchanging messages.

NOTE:

If an audit fails, the customer should call the CO to correct the problem from that end. Repeat the audit when the problem is fixed.

Auditing Lines

Summary

Procedure

PC Procedure

Appropriate Slot or Port

Time Estimate

Backup Procedure Busy-Out or Reset Interrupting the Test Restore

Menu Maintenance Port B-Channel Dial the

slot and port no. Enter Audit Lines

(F6)(F3)(F7)Type the slot and Port no .→(F10)(F1)

This test can be run only on the slot and port of a DS1 PRI B-channel.

4minutes Not required Not required

You cannot interrupt this test. Not required

Central Office Problems 5–25

Page 495
Image 495
AT&T 3.0 manual Auditing DS1 PRI B-Channels, Auditing Lines Summary