Roberts Gorden CTU 22 TO 115 service manual Installation Clearances and Clearances to Combustibles

Page 10

COMBAT® CTU UNIT HEATERS INSTALLATION OPERATION AND SERVICE MANUAL

WARNING

Fire Hazard

Some objects will catch fire or explode when placed close to heater.

Keep all flammable objects, liquids and vapours the required distance away from the heater.

Failure to follow these instructions can result in death, injury or property damage.

Figure 1: Installation Clearances and Clearances to Combustibles

Installation Clearances

Roof Terminal

Air

Intake

Flue Wall

Terminal 60 cm

15 cm

3 m

Clearances to Combustibles

15 cm

50 cm

50 cm**

30 cm

2.5- 3.5 m*

* Heaters may be mounted at a higher level if destratification fans and/or turn down nozzles are installed.

**80 cm is necessary to service heater.

The heater must always be installed at least 2.5 m above the floor.

The flue pipe must have clearance from combustibles by 5 cm.

If installed at low levels where individuals can come in contact with hot heat exchanger components, adequate guarding must be provided.

All distances are minimum clearance requirements for service access, air flow and safety.

4

Image 10
Contents Follow the gas supplier’s Instructions Immediately call your local gasSupplier after leaving the building Supplier, call the Fire DepartmentPage Roberts-Gordon, LLC Page Table of Figures Page Product Approval Clearances to Combustibles Heater SafetyInstaller Responsibility Corrosive ChemicalsVentilation Minimum Required Installation ClearancesCritical Considerations 3.1 Basic Information Gas SupplyInstallation Clearances and Clearances to Combustibles Top View Specifications 4.1 CtuaDimension Data Ctua All Models End View Rear ViewDimension Data CTUB, Ctuc and Ctud CTUB, Ctuc and CtudGeneral Technical Data Table Gas rates corrected to standard conditions 1013.25 mbar 15 C Heater Installation 5.1 General HandlingType B22 Appliance Flue Installation 6.1 Flue InstallationAir Intake Terminal Cover Vertical and Horizontal Flue Termination Type B22 Appliance AIR Supply Distribution Duct Work for CTUB, Ctuc and Ctud Heaters Optional Heater ConfigurationsCtud Heaters Option a GAS PipingConnections Option BWiring and Electrical Information Ctua Wiring Diagram Models 50 HzSite Wiring Site Wiring CTUB/C Wiring Diagram ModelsIgnition Module 230 V 1 Ø 50 HzRUN Ctud Wiring Diagram Models For external fan wiringSite Wiring and Electrical Information Electrical Checks CommissioningLouvres Mechanical ChecksAutomatic Burner Control Box Sequence End ViewCheck Gas Rate Combustion TestingTurning Off the Heater Complete the Commissioning External ControlsInstruction to the User Common User Controls Thermostat Limit Thermodisc Burner Lockout Reset ButtonHeater Operation Lighting Instructions To Turn On HeaterSimple Fault Finding Burner Faults Simple Fault FindingTo Turn the Heater Off Heat Exchanger Maintenance Burner Maintenance13.3 Fan/Motor Assembly Maintenance Gas Control Valve MaintenanceBurner Conversion Conversion Between Gases 14.1 GeneralGas Valves Conduct Commissioning procedure as shown on Page 24, Section StartFor your safety and optimum heater performance Troubleshooting For Automatic Ignition Burner SystemsConduct Commissioning procedure as shown Troubleshooting for Flame Supervision System Troubleshooting for Solenoid ValvesRemoval and Replacement Parts Burner Compartment Burner InjectorsIgnition Electrode and Flame Probe Remove screws securing outlet flange to the flue adapter Pressure Switch RG P/NTo Replace the Fan Assembly Ctua Axial Fan/Guard/Motor AssemblyFan Removal and Replacement Ctub & Ctuc Centrifugal Fan/Guard/Motor AssemblyCentrifugal Fan Orientation Fan DataPage Page Page Some objects can catch fire or explode when placed

CTU 22 TO 115 specifications

The Roberts Gordon CTU 22 TO 115 is a renowned unit heater designed to deliver efficient heating solutions in commercial and industrial settings. Known for its advanced features and robust design, this unit heater is ideal for applications where warmth and comfort are essential, such as warehouses, manufacturing facilities, and large retail spaces.

One of the main features of the CTU 22 TO 115 is its powerful heating capacity. With a range of output capabilities, it can effectively heat large areas, ensuring that employees and equipment remain comfortable during cold weather. The heater's output is adjustable, allowing for tailored heating solutions based on specific operational needs.

This model integrates several innovative technologies to enhance efficiency and performance. The use of advanced combustion technology ensures optimal fuel efficiency, which translates to lower energy costs and reduced environmental impact. The heater is available in both gas and oil configurations, providing versatility to accommodate different fuel sources depending on availability and preference.

In addition to its energy efficiency, the Roberts Gordon CTU features a compact design, making it suitable for installations in tight spaces. Its lightweight construction allows for easy installation and relocation, ensuring that businesses can quickly adapt to changing layout requirements. The unit is equipped with high-quality materials and a durable finish, contributing to its longevity and low maintenance needs.

Safety is a paramount concern in any heating system, and the CTU 22 TO 115 doesn't disappoint. It comes with various safety features, including over-temperature protection, ensuring that it operates securely under all conditions. With automatic shutoff capabilities, the heater provides peace of mind to operators, allowing for unattended operation in more remote settings.

Moreover, the CTU’s quiet operation is a significant advantage, as it minimizes disruption in the workplace, ensuring a comfortable environment for personnel. Its design also facilitates easy access to components for maintenance, thus ensuring that the unit remains operational with minimal downtime.

Overall, the Roberts Gordon CTU 22 TO 115 combines performance, efficiency, and safety features to create a reliable heating solution for diverse industrial applications. Its adaptability to various fuel types and efficient design makes it a popular choice among facility managers looking for dependable heating solutions.