Wireless remote controller kit
2.In order to later pass the Signal receiving unit wiring out through the upper case (thin part at the top center), use nippers or a similar tool to cut a notch in the same size as the Signal receiving unit cord (optional). (Fig. B)
Installation Manual
Notch where Signal | Cable tie | ||
receiving unit cord |
|
| |
passes through top case |
|
| |
| Connector | Signal receiving | |
|
| unit cord | |
|
| (optional) |
Fig.B
3.Disconnect the wires that were connected to the connector at the time of shipment.
4.Fasten the Signal receiving unit cord (optional) at the position shown in Fig. C, using the provided cable tie. Then connect the cord to the Signal receiving unit connector.
5.Shape the Signal receiving unit cord as shown in Fig. C so that it fits at the top inside the Signal receiving unit, above the PCB. Then attach the lower case. At this time, bend the head of the cable tie so that it faces sideways.
Signal receiving unit cord | ||||
(optional) |
|
|
| Wood |
|
|
|
| |
Clamp |
|
|
| screws (2) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fig.C
Signal receiving unit
1 | 2 | 3 |
4 | 5 | 6 |
6.Remove the nameplate and use 2 wood screws to attach the Signal receiving unit.
7.Use the provided cord clips to fasten the Signal receiving unit cord to the wall.
8.Reattach the face plate.
If the separate Signal receiving unit is installed on the ceiling, use the provided ceiling mounting bracket for installation.
1.Insert a screwdriver or similar tool into the notch at the bottom to remove the Signal receiving unit face plate.
2.Cut a section out of the ceiling along the provided paper
pattern (3.7” x 2” (95 x 51 mm)).
3. Pass the wire through the provided mounting bracket and insert the bracket into the installation hole. (Fig. D)
Fig.D
EN |
– 6 – |