Toshiba RAS-13GAVP-E, RAS-B16GKVP-E, RAS-B13GKVP-E, RAS-B10GKVP-E Construction Views, Indoor Unit

Page 15

4. CONSTRUCTION VIEWS

4-1. Indoor Unit

RAS-B10GKVP-E

RAS-B13GKVP-E

RAS-B16GKVP-E

 

790

 

 

 

Plasma pure filter

Indoor heat exchanger

 

Front panel

 

 

 

 

 

 

790

Air filter

215

 

 

 

 

250

 

 

7 60

 

 

 

 

60

53

Zeolite-plus filter

 

53

7

Knockout system

Air ionizer

Knockout system

 

53

 

 

53

54.5

60

60

54.5

Installation plate hanging section

Installation plate

290

Drain hose

hanging section

 

(Outside length:0.54m)

Connecting pipe

Connecting pipe

(Outside length:0.45m)

(Outside length:0.4m)

Flare Ø6.35

Flare Ø9.52

 

(RAS-B16GKVP-E : Ø12.7)

 

Remote controller holder

64 5

125.5

Wireless remote controller

58 19

163

Parts name of remote controller WH-H03JE

250

167.5

 

42

91

Minimum distance to wall

140 or more

3

91

 

 

674

 

 

25

10

10

450

10

10

Stud bolt hole

288

for Ø6

 

Hanging

more

Minimum

 

Stud bolt hole

 

section

 

 

distance

 

 

 

or

to ceilinfg

 

for Ø8 to Ø10

 

 

47

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum

 

 

 

 

 

 

distance

 

 

 

 

 

 

to wall

 

 

 

 

 

 

74 or more

 

 

 

 

 

 

42

Lower part

 

 

Outline of

 

 

hanging section

 

 

 

 

 

 

installation plate

 

 

 

 

 

 

 

Center line

 

 

Center line of

 

 

 

of main unit

 

 

 

 

 

 

 

installation plate

 

 

 

 

 

 

 

304

 

 

304

 

91

 

 

790

 

 

 

– 15 –

Image 15
Contents Split Type Contents Safety Precautions New Refrigerant Air Conditioner InstallationFor general public use For Reference Specifications SpecificationsCooling Operation Characteristic CurveCapacity Variation Ratio According to Temperature Cooling HeatingPiping Materials and Joints Used Safety During Installation/ServicingRefrigerant Piping Installation Refrigerant R410A1 Thicknesses of annealed copper pipes Thickness mm Flare processing procedures and precautionsProcessing of Piping Materials Joints13.2 13.5 12.70 16.6 16.0 12.9 15.88 19.7 19.0 Flare tool for R410A Conventional flare toolClutch type Wing nut type Flare tool for R22 Conventional flare toolWrenches available on the market Flare Connecting Procedures and Precautions43˚ Nm kgfcmTools Required ToolsGeneral tools Conventional tools can be used Recharging of Refrigerant 1 Configuration of refrigerant chargingBrazing of Pipes Materials for BrazingFlux Never use gas other than Nitrogen gas BrazingIndoor Unit Construction ViewsOutdoor Unit Detailed a leg partDetailed B leg part Wiring Diagram ColorIdentification Specifications of Electrical Parts Parts name Type SpecificationsParts name Model name Rating Refrigerant Cycle Diagram Refrigerant Cycle DiagramRAS-B13GKVP-E/RAS-13GAVP-E, RAS-B16GKVP-E/RAS-16GAVP-E Outdoor MPa T1 C T2 C Rps Temperature Standard Heat exchanger Compressor Condition COperation Data Cooling OutdoorHi-POWER Air Purifier Control Block DiagramRemote Controller Operation START/STOP Operation Mode SelectionMCC5009 P.C.B AssemblyOutdoor Unit Inverter For Indoor UnitRole of outdoor unit controller Operation DescriptionOutline of Air Conditioner Control Role of indoor unit controllerAuto Restart Function Filter IndicatorRemote Controller and Its Fuctions Operation DescriptionRemote controller Indoor unitOutdoor unit +0.5 Cooling operationTs + +1.0+ H SymbolsIndication Fan speed + MCold draft preventive control Operation flow and applicable data, etc DescriptionHeating operation Indication Fan speedOFF status Operation command Outdoor fan controlAir conditioner Alarm Outdoor unitOutdoor temp Cooling current Heating current Release value Remote controller Indoor unitWhen temperature of the indoor Defrost operation Operation flow and applicable data, etcCase of operation stop ConditionAir direction PowerfulThis function controls the air direction of the indoor unit Louver position in cooling operationFan Cooling operationOperation button Present status Pure button Air conditionerLouver*1 Fan speed *2 Purpose OperationTd value Control operation Ta sensor control Move toSH control PMV open degree control Stop by Room temp. sensorOperation mode Operation time Clean operation time Clean operationIndoor P.C. board Setting the clean operationSetting the selector switch on the main unit Setting the remote controllerHow to Set the Auto Restart Function When the unit is standby Not operatingWhen the unit is in operation When the system is operating Power Failure During Timer OperationHow to Turn Off Filter Indicator When the system is on stand-by not operatingParts Name of Remote Controller Display Heating operation Hi-POWER mode can not be set in Dry operationAutomatic operation Cooling operationSafety Cautions Installation ProcedureAttachment bolt arrangement of outdoor unit Optional Parts, Accessories and ToolsOptional Installation Parts Accessory and Installation PartsNew tools for R410A Applicable to R22 model Changes Installation/Servicing ToolsChanges in the product and components New tools for R410AWhen install the refrigerant pipes from the rear Installation PlaceRemote controller Mounting the installation plateWhen the installation plate is directly mounted on the wall Wiring Connection How to connect the connecting cableElectrical Work Changing drain hose How to remove the drain capHow to remove the drain hose Die-cutting front panel slitLeft-hand connection with piping How to attach the drain capHow to attach the drain hose Case of bottom right or bottom left pipingDrainage Indoor Unit InstallationPrecautions for adding refrigerant Flaring size B Unit mm Draining the WaterRefrigerant Piping Connection Flaring Projection margin in flaring a Unit mmUse a vacuum pump Tightening ConnectionHexagonal wrench is required Packed Valve handling precautionsWiring Connection Stripping length of connecting cableGas Leak Test Auto Restart SettingHow to Set the Auto Restart Test OperationJAVP-E series insulated type HOW to Diagnose the TroublePrecautions when handling the new inverter 3DV Inverter Control circuitry has an uninsulated constructionDischarging method Do not lay the circuit board assembly flatOperation Which is not a Trouble Program Operation Confirmation of Power SupplyConfirmation of Power Voltage First ConfirmationCheck Primary JudgmentJudgment by Flashing LED of Indoor Unit Block display Description for self-diagnosis CodePress on or OFF button Self-Diagnosis by Remote Controller Check CodeHow to Use Remote Controller in Service Mode Press START/STOP button to release the service modeStatus Block distinctionAir Judgment and action Block Cause of operation RemarksBlock distinction Operation of diagnosis function Judgment of Trouble by Every Symptom Indoor Unit Including Remote ControllerIs the fuse F01 blown? Is it possible to Only the indoor motor fan does not operate Primary checkInspection procedure Troubleshooting for remote controller Primary check Normal time Wiring Failure Interconnecting and Serial Signal WireInverter Assembly check Outdoor unit does not operateCheck Code 1C Miswiring in indoor/outdoor units and 1E Check procedure1C1E Operation check TroubleshootingHow to Check Whether the Air Purifier is Good or Not Conduction check of micro-switchPrimary check How to Check Whether the Minus Ion Generator is Good or NotHow to Diagnose Trouble in Outdoor Unit Summarized Inner Diagnosis of Inverter AssemblyDiagnosis/Process flowchart Contents Summary Inspection procedures How to Check Simply the Main PartsHow to Check the P.C. Board Indoor Unit Operating precautionsProcedure Check points Causes Check proceduresResistance value k 100 Sensor characteristic table11-9-2. P.C.BoardLayout +12V +5VPart name Part name Checking procedureIndoor Unit Other Parts OutdoorUnitChecking Method for Each Part Case that product is goodTester rod Resistance value Good product CN300 SymptomHOW to Replace the Main Parts Part name Procedures Remarks12-1 Indoor Unit How to assemble the front panel How to assemble the high voltage generator Drain pan above the claws and at How to assemble the electric parts boxSecure it Remove the two screws used to secure Bearing base Raise the left side of the heat exchangerSlightly, and remove the bearing base Secure using the fixing screw Screw Motor band Right Drain pipe Part name Procedure Remarks MicrocomputerBoard layout Attachment Wear gloves for this jobOtherwise, you may injure your Hands on the parts, etcProcedure Remarks Front cabinet Detachment Some cases Disengage the four claws of the P.C. board base ProcedureTerminal block Lead connected to compressorSide cabinet left Take care to keep the 4-way valve away With a burnerHandling precaution TE sensor outdoor heat exchanging temperature sensor TS sensor Suction pipe temperature sensorShown in the above figure is Parts name Qty Remarks Part name ProcedureMCC-5009 221 43047671 Pipe, Outlet Exploded Views and Parts List13-1 Indoor Unit Part Description402 407, 408 403 404 406 410401 405 14, 15, 17, 18 104 13-3. P.C. Board Layout Applicable Models RAS-10GAVP-E, RAS-13GAVP-E, RAS-16GAVP-E Required parts for installation work RecommendationPart name ’ty Specifications/Vendor Remarks Appendix-1Required tools for installation work Part name Specifications UsageAppendix-2 Appendix-3 Cord heater installation wiring diagramCord heater installation work procedure Photo / Explanatory diagram ProcedureAppendix-4 Used screw Screw type Quantity Appendix-5Appendix-6 Appendix-7 Appendix-8 Photo / Explanatory diagram Procedure AssemblyDrawing of thermostat fixing plate Material SGCC-Z08, Thickness 0.8t Appendix-9Ø3.4 burring hole Upward Ø3.4 burring hole Downward Appendix-10 Toshiba Carrier Corporation

RAS-10GAVP-E, RAS-16GAVP-E, RAS-13GAVP-E, RAS-B10GKVP-E, RAS-B13GKVP-E specifications

Toshiba has long been a renowned name in the world of air conditioning, delivering reliable and energy-efficient solutions that meet the demands of modern living. Among their innovative product line, the Toshiba RAS-B13GKVP-E, RAS-10GAVP-E, RAS-B10GKVP-E, RAS-16GKVP-E, and RAS-13GAVP-E stand out for their advanced features and cutting-edge technologies.

The RAS-B13GKVP-E is a powerful air conditioning unit designed for medium-sized rooms. It boasts a robust cooling capacity, ensuring comfort even during the hottest days. One of its standout features is the inverter technology, which optimizes energy consumption by adjusting the compressor speed according to the temperature, resulting in significant energy savings.

Next, the RAS-10GAVP-E is tailored for smaller spaces, offering efficient cooling and heating capabilities. It comes with an easy-to-use remote control and a user-friendly interface, allowing for effortless operation. The model also incorporates a quiet operation feature, making it suitable for bedrooms and study areas where noise can be a distraction.

The RAS-B10GKVP-E strikes a balance between size and efficiency, ideal for compact living spaces. Its dual cooling and heating function ensures year-round climate control. This model further enhances indoor air quality with its built-in filters, which capture dust and allergens, creating a healthier environment for occupants.

For larger areas, the RAS-16GKVP-E provides an impressive cooling capacity combined with turbo mode functionality. This feature enables rapid cooling of spaces during sweltering summer days. Its sleek design and compact form factor allow for easy installation, making this unit a popular choice for both residential and commercial applications.

Lastly, the RAS-13GAVP-E excels in energy efficiency with its eco-friendly refrigerant options. It is equipped with a smart control system that allows users to monitor and adjust settings remotely, adding convenience and flexibility to its operation. This model is particularly beneficial for users looking to minimize their carbon footprint while enjoying the comfort of climate control.

Overall, Toshiba's lineup of air conditioning units, including RAS-B13GKVP-E, RAS-10GAVP-E, RAS-B10GKVP-E, RAS-16GKVP-E, and RAS-13GAVP-E, promises high performance, energy efficiency, and advanced technology. These features affirm Toshiba's commitment to creating a comfortable indoor environment while ensuring sustainability and user satisfaction.