Toshiba RAS-B13SKVP-E, RAS-B10SKVP-E, RAS-10SAVP-E 240, 237, 108, Part Description, Location

Page 108

13. EXPLODED VIEWS AND PARTS LIST

13-1. Indoor Unit

RAS-B10SKVP-E, RAS-B13SKVP-E, RAS-B16SKVP-E

240

238

241

214

216

213

237

225, 226

230212

201

223

246

218, 219

247 205 221, 222, 224

202

245

229

206

204

 

233

 

 

232

The parts in the following parts list are conformed to RoHS.

Therefore be sure to use the following parts for repairing and replacing.

234

217

209

215

210211

239 227

Location

Part

Description

No.

No.

 

 

 

 

201

43005709

Panel Ass’y, Front

202

43009694

Grille, Air Inlet

204

43080512

Filter, Air, Right

205

43080521

Filter, Air, Left

206

43009693

Louver, Horizontal

209

4302C067

Motor, Fan, DC

210

4302D003

Motor, Louver

211

4306A024

Cord, Motor, Louver

212

43039363

Band, Motor, Left

213

43039321

Base, Bearing

214

43020346

Fan, Cross Flow

215

43039314

Band, Motor

216

43020253

Bearing

217

4301V028

Holder, Pipe

218

43049701

Pipe, Shield (B16SKVP-E)

219

43049698

Pipe, Shield

 

 

(B10SKVP-E, B13SKVP-E)

221

43047671

Pipe Ass’y, Connecting, Gas

 

 

(B10SKVP-E, B13SKVP-E)

222

43047672

Pipe Ass’y, Connecting, Gas

 

 

(B16SKVP-E)

 

 

 

Location

Part

Description

No.

No.

 

22343049674 Spring (B16SKVP-E)

22443047673 Pipe Ass’y, Connecting, Liquid

22543044821 Evaporator Ass’y (B10SKVP-E, B13SKVP-E)

22643044822 Evaporator Ass’y (B16SKVP-E)

22743039324 Guide, Drain

22943019904 Holder, Sensor

23043049770 Holder, Evaporator, Right

23243062256 Cover, Terminal

23343062247 Cover, Lead

23443082293 Plate, Installation

23743083071 Holder, Remote Controller

23843003311 Body Ass’y, Back

23943070188 Hose, Drain

24043079268 Cap, Drain

24143066014 Remote Controller,

WH-H04JE

24543080528 Plasma Pure Filter

24643080563 Generator Ass’y, HV

2474308N971 Owner’s Manual

– 108 –

Image 108
Contents AIR-CONDITIONER Contents New Refrigerant Air Conditioner Installation For general public useFor Reference Specifications SpecificationsRAS-10SKVP-ND RAS-13SKVP-ND RAS-16SKVP-ND Operation Characteristic Curve HeatingCooling CurrentCapacity Variation Ratio According to Temperature CoolingHeating Capacity ratio % 110 100Safety During Installation/Servicing Refrigerant Piping InstallationPiping Materials and Joints Used Copper PipesFlare processing procedures and precautions Processing of Piping MaterialsJoints Flare tool for R410A Conventional flare tool Clutch type Wing nut typeFlare tool for R22 Conventional flare tool DiameterFlare Connecting Procedures and Precautions Nm kgfcmWrenches available on the market Tools Required ToolsGeneral tools Conventional tools can be used 1 Configuration of refrigerant charging Recharging of RefrigerantBrazing of Pipes Materials for BrazingFlux Brazing Never use gas other than Nitrogen gasConstruction Views Indoor UnitWH-H05JE Mounting dimensions of anchor bolt Outdoor UnitDetailed a leg part Detailed B leg partBoard MCC-5009MCC-5045 RAS-10SAVP-ND, RAS-13SAVP-ND, RAS-16SAVP-NDParts name Type Specifications MP24Z3NParts name Model name Rating CAM-MD12TF DC12VRefrigerant Cycle Diagram CAM-B22YGTF-3Operation Data Cooling Operation START/STOP Operation Mode Selection Sleep ModeAUTO, COOL, DRY, Heat Outdoor Unit Inverter Assembly For Indoor UnitMCC5009 P.C.B Outline of Air Conditioner Control Role of indoor unit controllerRole of outdoor unit controller  Operations followed toFilter Indicator Remote Controller and Its FuctionsOperation Description Auto Restart FunctionRemote controller Indoor unitOutdoor unit ON/OFFAuto operation DRY operationSymbols Indication Fan speedIndoor fan air flow rate Operation flow and applicable data, etc Description Heating operationIndication Fan speed Cold draft preventive controlOutdoor temperature To Mode, by the conditionsOutdoor fan shown Table is selectedRemote controller Indoor unit When temperature of the indoor Exchanger detects evaporation temperature and controlsCompressor speed so that temperature of the heat Exchanger detects condensation temperatureOperation flow and applicable data, etc Case of operation stopCondition Defrost operationLouver position in cooling operation Louver position in heating operationLouver position in dry operation Air directionSleep ModeCooling operation When keeping Reset button pushed for If the filter lamp goes on, push ResetPush Reset button again TemporaryPurpose OperationSetup value Power OFF SH control Release control PMV open degree control Stop byClean operation Setting the clean operation cancel Setting the clean operationThis completes the clean operation setting Indoor P.C. boardSetting the remote controller Setting the unitIndoor control P.C. board At shipment Purpose Heat operation8C Heat operation -ND model only To reduce noise, Reset button OutdoorWith Quiet control/Non-select method Purpose Start During stop of air conditionerDuring operation of air conditioner On 8˚C HeatBasic fan control Indoor fan controlAuto TSC Compressor speed control Refer to 4. Capacity controlBase plate cord heater control Purpose To temp Heater output OperationOFF How to Set the Auto Restart Function When the unit is standby Not operatingWhen the unit is in operation Power Failure During Timer Operation How to Turn Off Filter IndicatorWhen the system is on stand-by not operating When the system is operatingParts Name of Remote Controller Display Automatic operation Safety Cautions For the rear left and left pipingDo not allow the drain hose to become slack Optional Parts, Accessories and Tools Optional Installation PartsAccessory and Installation Parts Installation/Servicing Tools New tools for R410AChanges in the product and components New tools for R410A Applicable to R22 model ChangesInstallation Location Remote controllerDrilling and Mounting Installation Plate Mounting the installation plateWhen the installation plate is directly mounted on the wall Wiring Connection How to connect the connecting cableElectrical Work Anchor bolt Projection 15mm or lessHow to remove the drain cap How to remove the drain hoseDie-cutting front panel slit Changing drain hoseHow to attach the drain cap How to attach the drain hoseCase of bottom right or bottom left piping Left-hand connection with pipingIndoor Unit Installation DrainageShield pipe Drain hose Inside the room Precautions for adding refrigerant Strong windDraining the Water Refrigerant Piping Connection FlaringProjection margin in flaring a Unit mm Flaring size B Unit mmTightening Connection Use a vacuum pumpTo secure To tighten Packed Valve handling precautions Wiring ConnectionStripping length of connecting cable Model RASTest Operation Precautions when handling the new inverter 3DV Inverter Troubleshooting ProcedureControl circuitry has an uninsulated construction JAVP-E series insulated typeDo not lay the circuit board assembly flat Discharging methodSensor leads Inverter coverConfirmation of Power Supply Confirmation of Power VoltageFirst Confirmation Operation Which is not a Trouble Program OperationPrimary Judgment Judgment by Flashing LED of Indoor UnitWhich lamp does flash? Check Block display Description for self-diagnosis CodeSelf-Diagnosis by Remote Controller Check Code How to Use Remote Controller in Service ModePush START/STOP button to release the service mode Push on or OFF buttonBlock distinction Judgment and actionAir Block Cause of operation RemarksBlock Cause of operation Judgment of Trouble by Every Symptom Indoor Unit Including Remote ControllerConfirmation procedure Primary checkOnly the indoor motor fan does not operate Inspection procedure CauseTroubleshooting for remote controller Wiring Failure Interconnecting and Serial Signal Wire Check procedure Select phenomena described belowOutdoor unit does not operate Terminal block at indoor sideCheck Code 1C Miswiring in indoor/outdoor units and 1E Check procedure1C1E Troubleshooting How to Check Whether the Air Purifier is Good or NotConduction check of micro-switch Primary checkHow to Diagnose Trouble in Outdoor Unit Summarized Inner Diagnosis of Inverter AssemblyDiagnosis/Process flowchart Contents Summary How to Check Simply the Main Parts How to Check the P.C. Board Indoor UnitOperating precautions Inspection proceduresCheck procedures Procedure Check points CausesOPERATION, TIMER, Filter CoolSensor characteristic table 11-9-2. P.C. Board LayoutPart name Checking procedure Indoor Unit Other PartsOutdoor Unit Checking Method for Each Part Case that product is goodTester rod Resistance value Good product Symptom CausePart name Procedures Remarks 12-1 Indoor UnitHow to assemble the front panel How to assemble the high voltage generator How to assemble the electric parts box Slide the horizontal Remove the two screws used to secure Bearing base Pull out here Drain pipe Part name Procedure Remarks MicrocomputerBoard layout No. Part name Procedure Remarks Common 1. Detachment AttachmentNo. Part name Procedure Remarks 100 Some casesSTIT-4X8MSZN Disconnect the leads and connectors connected to Other parts from the control board assembly101 Board base102 Side cabinet left103 Handling precaution 104Detachment 105 Detail a Arrow D Detail CDetail B Detail a Arrow D106 Parts name Qty RemarksPart name 107 MCC-5009MCC-5009-04 240 237108 Part Description402 407, 408 403 406 404 405 410401 109110 402 411, 412 403 406 404 405 410401 11113, 16, 19 14, 15, 17 20, 21, 23, 24 112113 13, 16, 19 14, 15, 17 20, 21, 23, 24 CORD, HEATER, Ass’y 114115 13-3. P.C. Board Layout 116117 118 CorrespondingModel Toshiba Carrier Corporation

RAS-10SAVP-E, RAS-B10SKVP-E, RAS-B13SKVP-E specifications

Toshiba has established itself as a leader in the HVAC market, known for its innovative technologies and reliable performance. Among its range of air conditioning units, the Toshiba RAS-B10SKVP-E, RAS-10SAVP-E, and RAS-B13SKVP-E models stand out for their efficiency and advanced features.

The Toshiba RAS-B10SKVP-E is designed for optimal cooling and heating efficiency, making it an ideal choice for small to medium-sized rooms. One of its main features is the Super Hi-M-PAM inverter technology, which enhances energy savings by continuously adjusting the compressor speed to match the cooling demand. This results in lower energy consumption while maintaining a stable temperature. Additionally, the unit boasts a 4-in-1 operation mode that allows users to select cooling, heating, dehumidification, or ventilating modes, ensuring maximum comfort at all times.

Similarly, the RAS-10SAVP-E model incorporates advanced features such as an eco-friendly refrigerant, R32, which has a lower Global Warming Potential (GWP) compared to traditional refrigerants. This model is equipped with a high-efficiency filter that captures dust and allergens, ensuring cleaner air quality. The sleek design allows for easy integration into various interior styles, while its quiet operation makes it a preferred choice for residential environments.

The RAS-B13SKVP-E model takes performance to the next level with a robust cooling capacity, designed for larger spaces. This model utilizes Toshiba's unique DC Hybrid Inverter technology, which not only enhances cooling efficiency but also facilitates faster temperature control. A notable characteristic of this unit is its wide-angle air distribution system, which allows for even airflow throughout the room, enhancing comfort.

In addition to these features, all three models are equipped with smart controls that enable users to operate their air conditioning systems remotely via mobile devices. This connectivity adds convenience and ensures that users can manage their indoor climate at their fingertips. They also come with user-friendly interfaces and programmable timers, allowing for personalized comfort settings.

In conclusion, the Toshiba RAS-B10SKVP-E, RAS-10SAVP-E, and RAS-B13SKVP-E air conditioning units combine energy efficiency, innovative technology, and user-friendly features to deliver exceptional indoor comfort. With their advanced technologies, these models are ideal choices for anyone seeking reliable and effective climate control solutions.